8. Technical Data

The hob is an independent Class 3 built-in unit.
This hob is category II
2H3
It is supplied set for group H natural gas. A conversion kit from NG to LP gas is packed with the hob.
INSTALLER: Please leave these instructions with the user.
DATA BADGE LOCATION: Base of the hob.
COUNTRY OF DESTINATION: GB/IE
Natural Gas
Butane
Propane
(See appliance data badge for test pressures)
Dimensions
Overall height
Overall width
Overall depth
Space for fixing
Minimum space above hotplate
Connections
Gas
Rp ½ at rear right-hand side
Ratings
Hotplate
Triple ring burner
Large Burners
Medium Burners
Small Burner
Gas burner inputs based on Gross Calorific Value
Maximum total electric load at 230V: 0.6W
+
Gas
120mm including gas connector
Natural Gas
3.5kW
3.0kW
1.75kW
1.0kW
20mbar
29mbar
37mbar
100mm;
720mm; see 'Positioning of Cooker'
See 'Positioning of Cooker'
Electric
220 – 240V 50Hz
Injector
141
129
101
77
14
Electric
220 – 240V 50Hz
Above worktop 50mm;
Below worktop 50mm
510mm
650mm
L.P. Gas
3.5kW (255g/h)
3.0kW (218g/h)
1.75kW (124g/h)
1.0kW (73g/h)
Injector
94
87
66
50