Changzhou Tonghui Electronic TH2821B Operation Manuals

Portable lcr meter

Advertisement

Quick Links

TH2821B
Portable LCR Meter
OPERATION MANUAL
English
February 2006
st
1
Edition Rev 1.0.0
© Copyright 2006 Changzhou Tonghui Electronic Co., Ltd.
All rights reserved.

Advertisement

Table of Contents
loading

Summary of Contents for Changzhou Tonghui Electronic TH2821B

  • Page 1 TH2821B Portable LCR Meter OPERATION MANUAL English February 2006 Edition Rev 1.0.0 © Copyright 2006 Changzhou Tonghui Electronic Co., Ltd. All rights reserved.
  • Page 2: Table Of Contents

    TH2821B OPERATION MANUAL Contents Contents............2 Bookmark How to Contact UsError! defined. Incoming Inspection ........3 Notes on Use ..........4 Warranty: ...........5 Chapter 1 Overview...........7 1.1 Introduction ..........7 1.2 Main Functions ........7 1.3 Specifications........8 1.4 Environment Requirements....10 Chapter 2 Panel Illustration ......11 2.1 LCD Display Illustration ......
  • Page 3: Incoming Inspection

    TH2821B OPERATION MANUAL Incoming Inspection Inspect the shipping container for damage. The contents of the shipment should be listed as follows. If the contents are incomplete, if there is damage or defect, please contact our company or your nearest Sales and Service Office.
  • Page 4: Notes On Use

    TH26029 SMD component test fixture Notes on Use This meter is only for indoor use. Turn off the TH2821B while switching the power supply between battery and DC adapter or replacing the battery. Although internal circuit protection is provided, DC voltage or current may damage TH2821B.
  • Page 5: Warranty

    Take out the battery when the meter is not in use for more than 3 months. A single standard 9V battery can be used for the power supply. TH2821B will not work normally when battery voltage is less than 6V. The 12V AC to DC adaptor is recommended to be used for TH2821B power supply.
  • Page 6 TH2821B OPERATION MANUAL designated by our company. Warranty limitation The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by Buyer, Buyer-supplied software or interfacing, unauthorized modification or misuse, or improper site preparation or maintenance.
  • Page 7: Chapter 1 Overview

    It can measure six basic parameters, they are inductance L, capacitance C, resistance R, impedance |Z|, dissipation factor D and quality factor Q. TH2821B can fulfill the measurement needs of various component manufacturers and maintenance technicians. 1.2 Main Functions Test Parameter ....
  • Page 8: Specifications

    TH2821B OPERATION MANUAL be obtained. Data Hold . . . . This function can be used to freeze the current display value. 1.3 Specifications Parameter L-Q, C-D, R-Q and Z-Q Frequency 100 Hz, 120 Hz and 1 kHz Basic Accuracy: 0.3%...
  • Page 9 TH2821B OPERATION MANUAL (Continued) Correction Open and Short Zeroing Rate Approx. 3 meas/sec Terminals 5 terminals Power Supply 1604 9V battery or DC12V(100 mA) adapter Low Battery Approx. 6V Indication Power Normal: Approx. 30 mA Consumption Auto power-off: Approx. 500 nA Auto Power Approx.
  • Page 10: Environment Requirements

    <1 ± µ × 1.4 Environment Requirements Please do not operate TH2821B under the following . environment conditions, as any of them will directly affect measuring precision or damage the meter: Please do not operate the instrument in places where is dusty, vibrant, under direct sunlight, or where there is corrosive air.
  • Page 11: Chapter 2 Panel Illustration

    TH2821B OPERATION MANUAL Chapter 2 Panel Illustration 2.1 LCD Display Illustration Figure 2-1 LCD Display...
  • Page 12 TH2821B OPERATION MANUAL Description Description Battery Power Unit Indicator Indicator Remote Ranging Mode Indicator Indicator Beeper Primary Parameter Indicator Display Series/Parallel Frequency Indicator Indicator Comparator Primary Parameter Indicator Indicator Secondary Parameter Function Indicator Indicator Secondary DC Adaptor Power Supply Parameter...
  • Page 13: Keyboard Illustration

    TH2821B OPERATION MANUAL 2.2 Keyboard Illustration Figure 2-2 Keyboard Function POWER Power On/Off ○ PARA Parameter Selection ○ FREQ Frequency Selection ○ CLEAR CLEAR Selection ○ RANGE Range Selection ○ AUTO Range Auto Selection ○ Data Hold ○ Series/Parallel Indicator ○...
  • Page 14: Chapter 3 Operation

    TH2821B OPERATION MANUAL Chapter 3 Operation 3.1 Power on 1. Press POWER key to turn on TH2821B. 2. The operation system version will be displayed. 3. At last the instrument enters the measurement state. Figure 4-1 Measurement Display Measurement display description: 1.
  • Page 15: How To Operate

    TH2821B OPERATION MANUAL 3.2 How to operate 3.2.1 Key Functions 1. Parameter Setup : Press PARA key to select the following measurement parameter combinations L -Q, C-D, R-Q and Z-Q. : Units Description: µH µF R/|Z| kΩ MΩ Ω Table 4-1 Units |Z| is the absolute value of impedance.
  • Page 16 TH2821B OPERATION MANUAL 3. Range Setup: RANGE and AUTO keys are used to set the measurement range. AUTO key toggles ranging mode between “Auto” and “Hold”. RANGE keys are used to increase or decrease the measurement range, if the current ranging mode is “Auto”, then the ranging mode is changed to “Hold”...
  • Page 17 TH2821B OPERATION MANUAL Note : How to calculate the measurement range Example: Assume capacitance C=210pF, dissipation D=0.0010 and test frequency f=1 kHz. Solution: π ≈ ≈ Ω − π × 1416 × 1000 × × From the Table 4-2, we can get the correct measurement range is No.
  • Page 18 TH2821B OPERATION MANUAL (Quit) will be displayed in the secondary parameter display area. Note : OpeN (OPEN), Short (Short) and Quit (Quit) are selected and displayed automatically by the meter according to the impedance value of the device under test.
  • Page 19 TH2821B OPERATION MANUAL reliably and perform the short correction again. Th2821B measures the correction data at all frequency points and . all measurement ranges. The correction data is stored in the non-volatile memory. So you don’t have to perform the correction again, if the test conditions are not changed.
  • Page 20 TH2821B OPERATION MANUAL Series : Capacitance Cs f rom series to parallel : Circuit Mode : Dissipation: π Parallel: Inductance Lp f rom parallel to series : Circuit Mode : π Dissipation: Series: Inductance Ls f rom series to parallel :...
  • Page 21: Battery Replacement

    TH2821B OPERATION MANUAL Parallel: Here parameter with subscript s means the series mode, parameter with subscript p means the parallel mode. From the above equations, we can conclude that the conversion between series and parallel is determined by D or Q Q =1/D (...
  • Page 22: Clearing Instruction

    TH2821B OPERATION MANUAL Loosen the three screws with suitable driver and remove the bottom cover. Replace the degraded battery with a new DC 9V battery. Model 1604, 006P or other equivalent battery must be used. Alkaline battery is recommended. If the instrument is not in use for more than three months, if the external DC adapter is always be used, please take out the battery.
  • Page 23: Appendix

    TH2821B OPERATION MANUAL Appendix Message Code Table : Clear: Correction clear Open: Open correction OpeN Short: Short correction short — — — — : High limit of P1 Bin P1_: Low limit of P1 Bin No-Good Low limit of quality factor...
  • Page 24 TH2821B OPERATION MANUAL First Edition2006-2...

Table of Contents