Angle Accuracy *1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±2° for 90° rotation @ 30°/sec
Unit Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .degree
Button. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Bright LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6LED/ 1Red+5Green
Pre-setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 set
Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AAA x 2
Battery Life *2 (Continuous Operation) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 hrs.
Battery Life *2
(Standby) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 year
Operating Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-10˚~60˚
Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-20˚~70˚
Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Up to 90%
non-condensing
Drop Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 m
Vibration Test *3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10G
Environmental Test *4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pass
Electromagnetic Compatibility Test *5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pass
DAMM
SPECIFICATIONS
1
WARNING
AlwAys reAd
instructions
before using
tools
AlwAys weAr
sAfety
goggles
not
wAterproof
Rev. 02/17/12

Advertisement

Table of Contents
loading

Summary of Contents for Carlyle DAMM

  • Page 1 DAMM DAMM Digital Angle Meter with Magnet SPECIFICATIONS WARNING Angle Accuracy *1 ....... ±2° for 90° rotation @ 30°/sec Unit Selection .
  • Page 2 DIGITAL TORQUE WRENCH - LIMITED 12-MONTH WARRANTY Carlyle Professional Hand Tools warrants to the original purchaser that the company’s digital torque wrenches are free from defects in material or workmanship during the one year warranty period.  We will repair any digital torque wrench which fails to give satisfactory service due to defective workmanship or materials (excluding calibration) for 12 months from the date of original purchase. (Calibration is only covered by this warranty for each new unused torque...
  • Page 3: Features And Functions

    1. LED Indicator RSDAMMBC Battery Cap 2. Buzzer RSDAMMCS Blow Mold Case 3. LCD Readout for DAMM 4. Pre-Set Target Angle Selection Button No other internal parts are available due to the 5. Up Button sensitivity of this professional model. 6. Down Button Please utilize the repair facility listed under the 7.
  • Page 4: Hardware Reset

    Please reset the meter if this occurs. Refer to shut off. The meter will display a battery symbol the section labled "HARDWARE RESET" under the M- Memory indicator Er-- If the meter rotates too fast, will be shown. Press to zero reset the meter. If the meter does not reset successfully for a period of time, will be shown. Press to do zero-reset again. Ensure the meter is in place on the tool at rest and not in motion DAMM Rev. 02/17/12...
  • Page 5 • (M1~M9). Press to select Press to adjust the current angle. Note: • target angle when a target number is set, it will be saved on Press that memory number. Example. M1 set @ 20; if modify target changed to M1 set @ 21, it will be saved as 21 on angle the M1 setting until altered. Press DAMM Rev. 02/17/12...
  • Page 6 80% 2. There is also a buzzer to indicate reaching level of target value. The interval sound means the ((((((((..)))))))) over 100% meter has reached 80% of the target angle. The extended sound means you have surpassed 100% of the set target angle. DAMM Rev. 02/17/12...
  • Page 7: Setup Menu Introduction

    2. Recorded value menu N001 = 30.0 3.) Clear recorded values menu. 3. The last menu is the communication menu that is only used by a certified service center. Direction menu Record menu Record clear-all menu Communication menu DAMM Rev. 02/17/12...
  • Page 8 CLEAR A SINGLE RECORD To access the record menu. • Press to select data Press to select the data number you • want to delete. Press twice to delete the current data. • ( will be shown) If press once, will be shown. If you • want to abandon, just press to skip this menu. Continuously pressing will skip the setup menu • Abandon and go back to the current target angle screen. DAMM Rev. 02/17/12...
  • Page 9: Clear All Records

    STORAGE 1. When the wrench is not used for an extended period of time, remove the battery. 2. Keep a spare battery on hand when going on a long trip or to cold areas. 3. Do not mix battery types or combine used batteries with new ones. 4. Sweat, oil and water can prevent a battery’s terminal from making electrical contact. To avoid this, wipe both terminals before loading a battery. 5. Dispose of batteries in a designated disposal area. Do not throw batteries into a fire. DAMM Rev. 02/17/12...
  • Page 10: Troubleshooting

    Rotational speed of wrench was exceeded. the torque wrench - If this does not the torque wrench work, then should not exceed 30º per second. 2. Remove battery cap - then reinstall. Press the button to restart the torque wrench. Note 1. If the torque wrench is shut down while in angle mode, then restarted while not horizontal, four flashing zeros may appear in the display . Follow the same steps listed above for ER4 error code. See also "Angle Mode Warning" on page 4 of the manual to review correct procedures for changing the angle values. DAMM Rev. 02/17/12...
  • Page 11 DAMM DAMM Medidor Digital de Ángulo con Imán ESPECIFICACIONES WARNING Precisión de ángulo *1 ... . . ±2° para una rotación de 90° @ 30°/sec Selección de unidad......... . Grado AlwAys reAd Boton .
  • Page 12: Especificaciones

    Esta garantía le brinda derechos específicos. Usted puede contar con derechos adicionales los cuales varían de estado a estado. La obligación anterior es la única responsabilidad por parte de Carlyle Professional Hand Tools bajo ésta o cualquier otra garantía implicada y bajo ninguna circunstancia será responsable Carlyle Professional Hand Tools por ningún daño incidental ni consecuencial. Nota: Algunos estados no permiten la exclusión ni limitación de daños incidentales ni consecuenciales por lo que la limitación o exclusión anterior puede no ser aplicable para usted.
  • Page 13: Características Y Funciones

    Tapa de batería 2. Alarma/timbre RSDAMMCS Estuche moldeadp por soplado 3. Lectura de salida DCL para DAMM 4. Botón de selección de ángulo meta pre- Ninguna otra parte está disponible debido a la ajustado sensibilidad de este modelo profesional. Utilice 5.
  • Page 14: Apagado Automático

    Si el calibrador gira demasiado rápido, aparecerá. Presione a cero para reiniciar el calibrador. Si el calibrador no se reinicia exitosamente por un periodo de tiempo, aparecerá Presione para reiniciar a cero de nuevo. Asegúrese que el calibrador esté en lugar en la herramienta en repose sin ningún movimiento. DAMM Rev. 02/17/12...
  • Page 15 ÁNGULO” NOTA: Cada una de estas secciones deben ser enumeradas Torsión meta actual Presione PASO 3: AJUSTE EL ÁNGULO META • Presione para desplazarse entre los ángulos meta pre-ajustados (M1~M9). Presione para seleccionar el • Presione o para ajustar el ángulo actual. Nota: ángulo meta cuando se fija un número meta, éste se guardará Presione sobre ese número de memoria. Ejemplo. M1 ajustado @ para modificar el 20 si es cambiado al ajuste M1 @ 21 éste será ángulo meta guardado como 21 en el ajuste M1 hasta que sea cambiado. Press DAMM Rev. 02/17/12...
  • Page 16 ((...((..))...)) sobre el 80% 2. Hay también un timbre para indicar el nivel de alcance del valor meta. El sonido intervalo indica ((((((((..)))))))) sobre el 100% que el calibrador ha alcanzado un 80% del ángulo meta. El sonido extendido quiere decir que se ha sobrepasado el 100% del ángulo meta establecido. DAMM Rev. 02/17/12...
  • Page 17 2. Menú de valor grabado N001 = 30.0 3.) Menú de blanco actual borrado de valores grabados, y el último es el menú de comunicación el que es sólo usado por parte de un centro de servicio certificado. menú del archivo menú del archivo menú de borrado de todos los archivos Menú de la comunicación DAMM Rev. 02/17/12...
  • Page 18 • Presione dos veces para borrar el dato actual. aparecerá) • Si presione una vez, aparecerá. Si usted desea abandonar, sólo presione para saltar de este menú. Abandonar • Al presionar continuamente, se saltará del menú de inicio y se volverá a la pantalla de ángulo meta actual. DAMM Rev. 02/17/12...
  • Page 19 4. El sudor, aceite, y el agua pueden prevenir que el borne de la batería haga contacto eléctrico. Para evitar esto, limpie ambos bornes de la batería antes de cargar la batería. 5. Deseche las baterías en un área designada. No tire baterías en el fuego. DAMM Rev. 02/17/12...
  • Page 20: Diagnóstico De Averías

    Nota 1. Si se apaga el torquímetro mientras que éste esté en el modo de ángulo, y luego se encendió de nuevo cuando no estuvo en posición horizontal, pueden aparecerse cuatro ceros parpadeantes en el despliegue. Siga los mismos pasos alistados para el código de error ER4'. Vea también "Advertencia de modo de ángulo " en la página 4 del manual para repasar los procedimientos correctos para cambiar los valores de ángulo. DAMM Rev. 02/17/12...