Controlling the Monitor with a computer (RS-232C)
Others
Function
SCREEN SIZE
VOLUME
MUTE AUDIO
INFORMATION
MODEL
SERIAL NO
TEMPERATURE SENSOR
TEMPERATURE ACQUISITION
CAUSE OF LAST STANDBY MODE
LAN SETUP
DHCP CLIENT
IP ADDRESS
SUBNET MASK
DEFAULT GATEWAY
FTP connection
Monitor name
FTP Username
FTP Password
User name
Password
Auto logout time
Data port
Reflecting LAN setting
42
E
Command
Direction
Parameter
WIDE
WR
1-5
VOLM
WR
0-31
MUTE
WR
0-1
INF1
R
SRNO
R
DSTA
R
ERRT
R
STCA
W
0
R
DHCP
WR
0-1
IPAD
WR
XXXXXXXXXXXX XXXXXXXXXXXX X: Only number is ok. If the number is less than 3 digits, to 3 digits to fill 0.
SBMK
WR
XXXXXXXXXXXX XXXXXXXXXXXX X: Only number is ok. If the number is less than 3 digits, to 3 digits to fill 0.
DFGW
WR
XXXXXXXXXXXX XXXXXXXXXXXX X: Only number is ok. If the number is less than 3 digits, to 3 digits to fill 0.
FCHE
WR
0-1
MNTR
WR
XXXXXXXX
XXXXXXXX
FUSR
WR
XXXXXXXX
FPAS
WR
XXXXXXXX
USER
WR
XXXXXXXX
PASS
WR
XXXXXXXX
LOTM
WR
00000-65535
TCPP
WR
01025-65535
NTUP
W
1
Reply
1-5 1: WIDE, 2: NORMAL, 3: Dot by Dot, 4: ZOOM1, 5: ZOOM2
0-31
0-1 0: OFF, 1: ON
Value
Value
0 Internal temperature normal
1 Internal temperature abnormal has occurred and the monitor is in standby mode
2 Internal temperature abnormal occurred (To delete the information of temperature
abnormal, turn off the main power.)
3 Internal temperature abnormal has occurred and backlight brightness is dimmed
4 Temperature sensor abnormal
Value Returns the temperature at the temperature sensors.
Indicates a temperature sensor abnormality when "126" is returned.
Initialization
0 No detectable error has occurred
1 Standby mode by POWER button or MONITOR OFF button
2 Main power off by the main power switch
3 Standby mode by RS-232C or LAN
4 Input signal waiting mode by No Signal
6 Standby mode by abnormal temperature
8 Standby mode by SCHEDULE setting
20 Standby mode by OFF IF NO OPERATION setting
0-1 0: OFF, 1: ON
* Apply the settings to this monitor by NTUP.
Example: 192168150001
* Apply the settings to this monitor by NTUP.
Example: 255255255000
* Apply the settings to this monitor by NTUP.
Example: 000000000000
* Apply the settings to this monitor by NTUP.
0-1 0: OFF, 1:ON
XXXXXXXX
16 characters or less; half-width alphanumeric characters, "-", and "_".
XXXXXXXX
(The field can be left blank, but spaces cannot be entered.)
XXXXXXXX 8 characters or less; half-width alphanumeric characters, "-", and "_".
(The field cannot be left blank, and spaces cannot be entered.)
XXXXXXXX 8 characters or less; half-width alphanumeric characters, "-", and "_".
(The field cannot be left blank, and spaces cannot be entered.)
XXXXXXXX 8 characters or less; half-width alphanumeric characters, "-", and "_".
(The field can be left blank, but spaces cannot be entered.)
XXXXXXXX 8 characters or less; half-width alphanumeric characters, "-", and "_".
(The field can be left blank, but spaces cannot be entered.)
00000-65535 Set the time that display terminate a network connection automatically by minutes.
01025-65535 Set the TCP port number for data communication.
* Apply the settings to this monitor by NTUP.
1 Applies the DHCP CLIENT, IP ADDRESS, SUBNET MASK, DEFAULT GATEWAY,
and Data port settings to this monitor.
Control/Response contents
*
-