USER GUIDE
Wet Bulb Thermo-Hygrometer Datalogger
Plus Dew Point Temperature
Model WB200
ShopExtech
1.888.610.7664
Shop for Extech products at:
.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WB200 and is the answer not in the manual?

Questions and answers

Summary of Contents for Extech Instruments WB200

  • Page 1 USER GUIDE Wet Bulb Thermo-Hygrometer Datalogger Plus Dew Point Temperature Model WB200 ShopExtech 1.888.610.7664 Shop for Extech products at: .com...
  • Page 2: Powering The Meter

    Low battery indicator Powering the Meter The WB200 can be powered using the four (4) supplied 1.5V batteries (AAA) or the supplied 5V power adaptor; the adaptor is recommended for extended measurement sessions. When the low battery icon appears replace the batteries promptly. Operating in a low battery condition will affect vane rotation and measurement functions adversely.
  • Page 3: Meter Description

     Displays the Maximum (MAX) and Minimum (MIN) readings for a measurement session  Press and hold for at least 2 seconds to start datalogging to the meter’s internal memory  Used as an ENTER key in set-up mode for stepping and editing WB200-EU-EN V1.4 8/13 ShopExtech 1.888.610.7664 Shop for Extech products at: .com...
  • Page 4: Operation

    Refer to Figure 2 below. Figure 2 – Maximum (Mx) and Minimum (Mn) Display Modes                              o                            o C        C           Mx  Mn  WB200-EU-EN V1.4 8/13 ShopExtech 1.888.610.7664 Shop for Extech products at: .com...
  • Page 5 OFF. 3. To stop a datalogging session manually, while recording is taking place, the user must switch the WB200 OFF. Readings up to the point of power down will be retained for the user to view as described next.
  • Page 6: Setup Mode

    (in the same fashion as the HI Alarm). Note that the LO limit cannot be set higher than C or 1.8 F below the HI Limit. g. When finished, press ENTER ( ) to access the next parameter: WB200-EU-EN V1.4 8/13 ShopExtech 1.888.610.7664 Shop for Extech products at:...
  • Page 7 With ECO or CON displayed, use the key to select the desired mode b. When finished, press ENTER ( ) to return to the normal operation mode c. Setup is now complete WB200-EU-EN V1.4 8/13 ShopExtech 1.888.610.7664 Shop for Extech products at:...
  • Page 8: Troubleshooting

    / accumulators are sold. Disposal in household trash or refuse is prohibited! Disposal: Follow the valid legal stipulations in respect of the disposal of the device at the end of its lifecycle WB200-EU-EN V1.4 8/13 ShopExtech 1.888.610.7664 Shop for Extech products at:...
  • Page 9  To avoid spillage, do not tilt the meter during operation.  Refill the tank every 2 to 3 weeks for best results.  For best results, it is important that the wick be thoroughly saturated before use. WB200-EU-EN V1.4 8/13 ShopExtech 1.888.610.7664 Shop for Extech products at: .com...
  • Page 10: Specifications

    250g (8.0 oz.) with batteries installed Copyright © 2013 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form ISO-9001 Certified www.extech.com WB200-EU-EN V1.4 8/13 ShopExtech 1.888.610.7664 Shop for Extech products at: .com...