Turning on/off the Power
Press and hold the Power to turn on or off.
Low-Vo tage/High-Voltage Alert
This unit can operate on 12V DC (13.8V) or 24V DC (27.6V) power
supply , with the range between 10.2V DC to 28.8V DC.
If the power supply voltage exceeds 28.8V DC, an alert tone sounds
and HI DC flashes for 5 seconds. The power source must not exceed
!
32V DC otherwise permanent damage may occur to your radio, which
may not be covered by the manufacturer's warranty.
NOTE
If the input voltage falls below 10.2V DC, LO DC flashes for 5 seconds.
The power turns off automatically if voltage falls below 9.0V DC.
Turning your unit OFF and disconnect it from the power source, before
locating the cause of the power supply problem.
Operation
CTCSS DCS
/
PO FI
/
SCAN
l
DUAL
MEM
SQ
M.SEL
-8-