Condition
• Excessive burning.
(More than light brown)
Troubleshooting
Does the center thermostat operate
properly?
(Check with the evaporation test).
Yes
Are the parts on the P.C.B. mistake?
No
Improper operation
• Rice is not washed sufficiently
(Bran remains still)
• The pan bottom is conditioned to
generate burning easily.
• The voltage is lower than specified.
• Water is excessive.
- 6 -
Remedy
No
• Replace the center thermostat.
Yes
• Seeing at Table 2.
Yes
• Explain the proper operation.