NR-AH144 / NR-AH184
4. PERFORMANCE DATA
4.1 NR-AH144 (AT 32 ± 1°C)
Thermostat Dial Setting
Freezer Temperature
Fresh Food Compartment Temperature
Running Ratio
Power Consumption
4.2 NR-AH184 (AT 32 ± 1°C)
Thermostat Dial Setting
Freezer Temperature
Fresh Food Compartment Temperature
Running Ratio
Power Consumption
" 5 "
(°C)
-12.5 ± 2.5
(°C)
-6.0 ± 2.5
(%)
55 ± 15
(kWh/Day)
" 5 "
(°C)
-14.0 ± 2.5
(°C)
-5.0 ± 2.5
(%)
60 ± 15
(kWh/Day)
- 7 -
" 3 "
" 1 "
-6.5 ± 2.5
-0.5 ± 2.5
-1.0 ± 2.5
4.0 ± 2.5
35 ± 15
20 ± 15
0.9 or under
" 3 "
" 1 "
-6.5 ± 2.5
-0.5 ± 2.5
1.0 ± 2.5
6.5 ± 2.5
40 ± 15
25 ± 15
0.9 or under