Vermont Castings LSTF36 Installation Instructions page 2

Thermostatic blower

Advertisement

Installation Instructions - (LF,FL)
NOTE: The blower can be installed through the end access panel
at time of fireplace installation before framing.
1. Disconnect gas line and remove burner and logs.
2. Remove brick wall(s) and hearth floor. Figure 3
3. Remove blower access/mounting plate. Figure 3
4. Mount the blower to the mounting plate by using the four (4) rub-
ber grommets between the blower and plate. Attach with four (4)
#14 x 3/4 screws. Figure 5. NOTE: The blower may be mounted
on either side of unit according to which side the air is to be
discharged.
Install Thermal Sensor
NOTE: There are two (2) thermal sensors packed with this kit. Be
sure to install the correct sensor. Figure 6
1. Remove the thermal sensor plate located inside at top of fire-
place on the air channel. Figure 4
2. Route the two (2) thermal sensor wires down through the air
channel to the bottom blower compartment of the unit. Align
the thermal sensor and attach to the sensor mounting plate
with screws provided. After the sensor is mounted reinstall the
mounting plate with the screws previously removed. Figure 4
Attach Speed Control
1. Slide the speed control knob through slot from under the blower
compartment. Align mounting holes in side panel to mounting
bracket. Use two (2) #8 x 1/2 screws to attach. Figure 5
2. Connect wiring according to the wiring diagram. Figure 2
WARNING: It is important to wire tie the loose wires and arrange
the wiring harness neatly so the wires cannot come in contact
with blower fan blades.
3. Plug power cord into junction box.
4. Reinstall blower access panel/mounting plate with blowers in-
stalled.
5. Reinstall brick, burner and logs in reverse order of removal.
6. To operate blower, turn fireplace ON. Turn the knob on the
speed control clockwise. The blower should be operating
at the highest speed within 10 min-
utes. Continue to turn the knob until
it reaches the desired speed. If the
low speed is set too low, it can be
adjusted. Figure 6
2
Figure 2 -
Brick Removal
Speed
Blower
Control
Blower Access /
Mounting Plate
Figure 3 -
Speed Control Installation
KT1354
speed control
KT1353
brick removal
KT1353
KT1354
79D0009