Before You Start
This instruction sheet is ONLY for models listed below. Carefully inspect the contents for shipping damage. If any parts
are missing or damaged, immediately inform the dealer from whom you purchased the part.
Models: LSTF36, LPF36, LRF36, LLF36, 36STFL, 36PFL, 36RFL, 36LFL, (ST, CL, CR, PF)LDV
Kit Contents:
(1) Blower Assembly
(1) Speed Control
(1) Gasket
(1) Thermostatic Sensor (Large screw-in style)
Tools Required:
Phillips screwdriver, Small jeweler's style screwdriver
Before installing the blower, turn off the fireplace
and allow to cool. Only a qualified service person
should service and repair the fireplace. A qualified
service person should connect and disconnect the
fireplace to gas supply. Follow all local codes.
Electrical Grounding Instructions:
This appliance is equipped with a three-prong
(grounding) plug for your protection against shock
hazard and should be plugged directly into a prop-
erly grounded three prong receptacle.
Installation Instructions
Wiring
1. Before installing the blower, wire the receptacle into an electrical circuit. This should be done
before framing the fireplace. Wire with minimum 60° C wire in accordance with prevailing
codes.
2. Remove the external junction box cover by removing the screw
from the left side of the outside firebox wall. Junction box was
installed at the factory.
3. The junction box cover has a factory installed "romex" style strain
relief connector. After connecting the wires, route the wire leads
through this connector. Refer to the wiring diagram in Figure 1.
Thermostatic Blower
Installation Instructions
Model: BLOTDL
(4) Screws #14 x 3/4
(1) Speed Control Mounting Bracket (2) Wire Ties
(2) High Temperature Wire
(2) Screws #8 x 1/2
(4) Rubber Grommets
(1) Thermostatic Sensor (Small snap-in style)
Electrical connections should only be performed
by a qualified licensed electrician. Main power
supply must be turned off before connecting fans
to the main electrical power supply or performing
service.
IMPORTANT: Always check local building codes. This
installation must comply with local regulations as well
as the National Electric Code.
Junction Box
(1) Power Cord
Figure 1
Junction Box Wiring Diagram
120V AC
60Hz
Factory Supplied
Not Supplied
79D0009 1/13 Rev. 3

Advertisement

loading

Summary of Contents for Vermont Castings LSTF36

  • Page 1 This instruction sheet is ONLY for models listed below. Carefully inspect the contents for shipping damage. If any parts are missing or damaged, immediately inform the dealer from whom you purchased the part. Models: LSTF36, LPF36, LRF36, LLF36, 36STFL, 36PFL, 36RFL, 36LFL, (ST, CL, CR, PF)LDV Kit Contents:...
  • Page 2 Installation Instructions - (LF,FL) NOTE: The blower can be installed through the end access panel at time of fireplace installation before framing. 1. Disconnect gas line and remove burner and logs. 2. Remove brick wall(s) and hearth floor. Figure 3 3.
  • Page 3 Thermal Sensor Thermal Sensor Plate Figure 4 - Thermal Sensor Installation KT1355 KT1355 thermal sensor 120VAC Receptacle  Junction  WHITE GREEN FP2675 BLACK BLACK WHITE BLACK BLACK Speed Control  Figure 5 -     Blower Wiring Diagram         FP2675 BLOT blower wiring Adjustment Screw...
  • Page 4 If the low setting is set too low, it can moved. be adjusted. Figure 6 9. Attach the Speed Control: Bend one of the mount- ing tabs up 90° on the floor of the fireplace access Vermont Castings Group 149 Cleveland Drive • Paris, Kentucky 40361 www.vermontcastingsgroup.com 79D0009...

This manual is also suitable for:

Lpf36Lrf36Llf3636stfl36rfl36pfl ... Show all