    1. Safety Instructions 1.1 Transport Please read the FOLLOWING user manual and the safety instructions before installing the unit and starting it up! ★ Please transport the UPS system only in the original packaging (to protect against shock and impact). 1.2 Set-up ★...
  • Page 3: Operation

    1.4 Operation ★ Do not disconnect the mains cable on the UPS system or the building wiring socket outlet (shockproof socket outlet) during operations since this would cancel the protective earthing of the UPS system and of all connected loads. The UPS system features its own, internal current source (batteries).
  • Page 4 Do not open or destroy batteries. Escaping electrolyte can cause injury to the skin ★ and eyes. It may be toxic. Please replace the fuse only by a fuse of the same type and of the same ★ amperage in order to avoid fire hazards. Do not dismantle the UPS system.
  • Page 5 Model No. on the rear panel of the UPS. Model No. Type Model No. Type 1K RM 1KL RM 2K RM 2K RM Standard Long backup time 3K RM...
  • Page 6 4. System Description TOWER Display Panel Data display Working mode Graphic Normal mode Alarm mode LED Fault mode LED Enter- button UP – button DOWN ENTER button DOWN – Figure 1: TOWER Display Panel Buttons Function desription .Page up 5...
  • Page 7 DOWN Page down ENTER Confirm the selection When UPS is under battery, you can put this button for Mute. UP+DOWN=ON Turn on UPS system: UP+DOWN=ON By pressing the “UP”+”DOWN” together,UPS system is turned on. DOWN+ENTER=OFF When mains power is normal, the UPS system switches to Standby mode by pressing “DOWN”+”ENTER”...
  • Page 8 Mainly display UPS working condition , line mode, battery Working Display Area mode, bypass mode, fault mode Show the UPS working condition directly with graphic Graphic Display LCD display details as following:  Line Mode  Battery Mode  Bypass Mode 7...
  • Page 9  You can press “up” or “down” button change Page1~4, as following. Page 1 Left Right Page Battery number voltage Battery Battery quantity discharging current PBUS NBUS voltage voltage Page 2 Left Right Page Output number current the value of output active power(watt) The value of output total power (VA)
  • Page 10: Fault Code

    Fault code Page 4 Left Right Page Output number rated voltage Rated capacity Rated Soft wave frequenc version 4.2 R/T LCD display Working mode NOR. BAT. WAR. FAULT UP – Switch Data Zone DOWN Switch DOWN – ENTER /MUTE Alarm Indicator Enter- Switch Figure 2: RT Display Panel...
  • Page 11 BUTTONS Function .Page up DOWN Page down ENTER Confirm the selection When UPS is under battery, you can put this button for Mute. Turn on UPS system: DOWN+ENTER By pressing the Switches the UPS system is turned on. When mains power is normal, the UPS system switches to Standby mode by pressing the Switches.
  • Page 12 LCD display details as following:  Line Mode  Battery Mode 11...
  • Page 13 You can press “up” or “down” button change Page1~9, as following. NO.1 Input voltage and Input No.2 Batteraay voltage and frequency Battery quantity. NO.3 Battery current and Battery No.4 Output current and Load capacity. percent. No.5 Load Watt. Value and Load No.6 Temperature1 and VA Value temperature2...
  • Page 14: Connection And Operation

    Fault Code Table FAULT CODE FAULT CODE INV SHORT INV VOLTAGE LOW PBUS VOLTAGE OVER INV SOFT FAIL NBUS VOLTAGE OVER BUS DISCHARGE FAIL BUS SOFT FAIL INV OVER TEMPERATURE INV VOLTAGE HIGH DC OVER TEMPERATURE OVER LOAD NO FAULT Caution Code Table Caution CODE...
  • Page 15 Inspection: Inspect the packaging carton and its contents for damage. Please inform the transport agency immediately should you find signs of damage. Please keep the packaging in a safe place for future use. Note: Please ensure that the incoming feeder is isolated and secured to prevent it from being switched back on again.
  • Page 16 more than 1 second to turn on the UPS. Then the UPS will get into self-test status first. After having finishing the self-test, the UPS will get into the inverter mode, at this time, the LINE mode LED will light up. 4.2) Without utility power connecting: Even though utility power is not connected to the UPS, the UPS still can be turned on by just simply pressing “ON”...
  • Page 17: Electrical Specifications

    7.1 Electrical specifications INPUT Model No. 1K(S/L RM) 2K(S/L RM) 3K(S/L RM) 5K(S/L RM) 6K(S/L RM) Phase Single Frequency 50/60Hz OUTPUT Model No. 1K (S/L RM) 2K(S/L RM) 3K(S/L RM) 5K(S/L RM) 6K(S/L RM) Power 1kVA/0.9kW 2kVA/1.8kW 3kVA/2.7kW 5KVA/4KW 6KVA/4.8KW rating 108/110/120×(1 士...
  • Page 18: Operating Environment

    BATTERIES Model No. 5/6K 8×12V 7Ah Number and 3×12V 7Ah 8×12V 7Ah 8×12V 9Ah OR 6×12V 7Ah type OR 2×12V 7Ah OR 6×12V 7Ah OR16×12V 7Ah OR 4×12V 7Ah 7.2 Operating Environment Ambient Temperature C to 40 Operating humidity < 95% Altitude <...
  • Page 19: Communication Port

    Rack mode-3U 440*510*133 the following standards: EN62040-1-1 (safety) Conducted Emission: EN50091-2……………………………………Class B Radiated Emission: EN50091-2……………………………………...Class B Harmonic Current: EN61000-3-2 Voltage Fluctuations and Flicker: EN61000-3-3 EMS: EN61000-4-2(ESD)……………………………………………..Level 4 EN61000-4-3(RS) ……………………………………………………..Level 3 EN61000-4-4(EFT)…………………………………………………… Level 4 EN61000-4-5(lighting surge)………………………………………….Level 4 EN61000-2-2 (Immunity to low frequency signals) 9.
  • Page 20 contact your local distributor for details. The following is the pin assignment and description of DB-9 connector in AS400 card. Description Pin # UPS Fail Output Output Summary Alarm Input Remote Shutdown Input Common Input Bypass Output Output Battery Low Figure 16.2: DB-9 Interface of AS400 UPS ON Output...