Dvp4000Mki; Service Hints (Dvd4000Mki & Mkii) - Philips DVP4000MKI/69 Service Manual

Hide thumbs Also See for DVP4000MKI/69:
Table of Contents

Advertisement

EN 2
3139 785 3172x
Service Hints (DVP4000MKI & DVP4000MKII)
CAUTION
CHARGED CAPACITORS ON THE SERVO BOARD MAY DAMAGE THE DRIVE
ELECTRONICS WHEN CONNECTING A NEW DRIVE.THAT'S WHY, BESIDES THE SAFETY
MEASURES LIKE
SWITCH OFF POWER SUPPLY
ESD PROTECTION
ADDITIONAL ACTIONS MUST BE TAKEN BY THE REPAIR TECHNICIAN.
The following steps have to be done when replacing the defective loader :
1. Dismantling of the loader to access the ESD protection point if necessary.
2. Solder the ESD protection point*.
3. Disconnect flexfoil cable from the defective loader.
4. Put a paper clip on the flexfoil to short-circuit the contacts (fig.1)
5. Replace the defective loader with a new loader.
6. Remove paperclip from the flexfoil and connect it to the new loader.
7. Remove solder joint on the ESD protection point.
ATTENTION: The laser diode of this loader is protected against ESD by a solder joint which shortcircuits the laserdiode to ground.
For proper functionality of the loader this solder joint must be remove after connection loader to the set.
(ESD protection point is accessible from top of loader)
*Only applicable for defective loader needed to be sent back to supplier for failure analysis and to support backcharging
evidence.
This is also applicable for all partnership workshops.

DVP4000MKI

Type 1
Type 2
(ESD protection point is accessible from bottom of the loader)

Advertisement

Table of Contents