Technical Details - Ecom Instruments Ex-PT 720 Operating Instructions Manual

Hide thumbs Also See for Ex-PT 720:
Table of Contents

Advertisement

safe for Class I Zone 0 Group IIC hazardous (classfied) locations temperature
class T4 at a 50°C ambient.

6. Technical Details

Ambient temperature Ta:
Storage temperature:
Batteries:
Table with type-tested batteries:
Type
6 LR 61 Alkaline No.4822
6 LR 61 Alkaline Universal No. 4022
6 LR 61 Alkaline Elektric Power No. 8022
6 LR 61 Alkaline
6 LR 61 Alkaline Ultra
6 LR 61 Alkaline Batterie Procell
6 LR 61 Alkaline Power Line Industrial Battery
6 LR 61 Alkaline Energizer
6 LR 61 Alkaline
Operating life:
Dimensions:
Weight:
Case material:
IP-protective rating:
EC-designation:
Display:
Measuring device:
Measuring range:
The measuring range of the sensors within explosive zones depends on
the temperature class of the Ex-area and it is distinguished as follows:
T1: -10 ... 360°C
T2: -10 ... 210°C
T3: -10 ... 110°C
T4: -10 ... 50°C
-10 ... +50°C
-20 ... +70°C
9V-Block, 6LR61 as per IEC
(only type tested batteries)
approx. 100h
190 x 57 x 42 mm
approx. 200g (with batteries)
ABS
IP 54
0
0102
LCD, digit height 14mm
Pt 100-Sensor, 4-wire-technique
Manufacturer
Varta
Varta
Varta
Duracell
Duracell
Duracell
Panasonic
Ralston Energy
Daimon
19

Advertisement

Table of Contents
loading

Table of Contents