Security recommendations

To prevent unauthorized access, note the following security recommendations.
General
● You should make regular checks to make sure that the device meets these
recommendations and/or other security guidelines.
● Evaluate your plant as a whole in terms of security. Use a cell protection concept with
suitable products.
● When confidential zones are used, the internal and external network are disconnected, an
attacker cannot access the data from the outside.
● Operate the device only within a protected network area.
● Use additional devices with VPN functionality (e.g. SCALANCE S) to encrypt and
authenticate communication from and to the devices.
● For data transfer via a non-secure network, use an encrypted VPN tunnel (IPsec) by
using additional devices with VPN functionality (e.g. SCALANCE S).
● For operation of the device in a non-secure infrastructure no product liability will be
accepted.
● Separate connections correctly (WBM. Telnet, SSH etc.).
Physical access
● Restrict physical access to the device to qualified personnel.
● The memory card or the PLUG (C-PLUG, KEY-PLUG, security PLUG) contains sensitive
data such as certificates, keys etc. that can be read out and modified.
Software (security functions)
● Keep the software up to date. Check regularly for security updates of the product.
You will find information on this on the Internet pages "Industrial Security
(http://www.siemens.com/industrialsecurity) "
● Inform yourself regularly about security advisories and bulletins published by Siemens
ProductCERT.
● Only activate protocols that you really require to use the device.
● Use the security functions such as address translation with NAT (Network Address
Translation) or NAPT (Network Address Port Translation) to protect receiving ports from
access by third parties.
● Restrict access to the device with a firewall or rules in an access control list (ACL -
Access Control List).