      Table of Contents  TRENDnet User’s Guide                        Redundant Backup Setting ................ 17 Contents    Configuration  ..................... 17 Product Overview  ................  1     System Function .................... 17   Package Contents ...................... 1 Technical Specifications .............. 18     Features ......................... 1 Appendix .................. 20     Product Hardware Features  ................... 2  ...
  • Page 3: Product Overview

      TFC‐1600MM  TRENDnet User’s Guide                     Features   Product Overview  The TFC1600MM module supports the management of media converters and power  supplies installed in the TFC‐1600 fiber chassis.  This module provides instant access to  cooling fan and power supply status, and allows the user to configure and monitor the  state of the chassis by means of a workstation with support for SNMP, or from a PC via  web browser.         Event Notifications  Be notified when an event notification is raised and correct error conditions in a timely  manner to maintain network uptime.  Supports cold/warm start, link up/down,  authentication failure, power supply on/off, connected/disconnected, module  connected/disconnected, and unknown failure     Configuration  Configure settings such as link loss carry forward / link loss return, module name, reset  module, download software via HTTP, IP address / subnet mask / default gateway, and  redundant backup      TFC‐1600MM  Real‐time Monitoring     Real‐time monitoring provides the latest statistics on link status, slot occupied, revision,   ...
  • Page 4: Product Hardware Features

      TFC‐1600MM  TRENDnet User’s Guide                     Real‐Time Monitoring Product Hardware Features     Real‐time monitoring of link, speed, and duplex status of media converters.    LED Indicators  LEDs convey power on/off, power fail, fan fail, MGM, console, and link/activity             10/100/1000 Mbps Gigabit Ethernet Port ‐ To configure the device through  Web Browser or TELNET program via LAN Ethernet.   RJ‐45 UTP console port ‐ To configure the device through RJ‐45 UTP console  port.   LED Indicators  There are two powers at the rear and will indicate on the front panel the status  of the power and fan:  Power On  Lights green when the power is inserted.  Power Fail  Lights Amber when the power is inserted and it is fail.  Fan Fail ...
  • Page 5: Module Installation

      TFC‐1600MM  TRENDnet User’s Guide                     Module Installation    Installing the Management Module     Install the Management Module into the Media Converter Chassis.   Connect the Management Module to the network.        The chassis’s first slot is for the Management Module as illustration.  Slide in the management module in the first slot of the chassis system.            © Copyright 2016 TRENDnet. All Rights Reserved.      1   ...
  • Page 6: Configure Your Module (Web Management)

      TFC‐1600MM  TRENDnet User’s Guide                     Configure your module (Web Management)  This chapter provides network managers and system administrators with information about how to configure the Media Converter Chassis via the Management Module.   The reader of this document should be knowledgeable about network devices, device configuration, network management, and Internet browsers. The user is assumed to be a network  administrator or manager with an understanding of network operations.     Access your SNMP module management page  Note: Your switch default management IP address http://192.168.1.1 is accessed through the use of your Internet web browser (e.g. Internet Explorer®, Firefox®, Chrome™, Safari®, and  Opera™) and will be referenced frequently in this User’s Guide.     1. Open your web browser and go to the IP address http://192.168.1.1 . Your switch will prompt you for a user name and password.       2. Enter the user name and password. By default:  User Name: root    Password: root  Note: User Name and Password are case sensitive.              © Copyright 2016 TRENDnet. All Rights Reserved.      2 ...
  • Page 7: Main Menu

      TFC‐1600MM  TRENDnet User’s Guide                     Main Menu  The Main Menu will show out the Hardware Revision, BIOS Revision and Firmware Revision, to set the management system, click on the left side menu, System Function and  Configuration, in the center screen is the status screen that appears where you clicked on the left side menu.              © Copyright 2016 TRENDnet. All Rights Reserved.      3   ...
  • Page 8   TFC‐1600MM  TRENDnet User’s Guide                     Click on the Media Converter slot and it will appear a screen for you to monitor or control, depend on what media converter you are using.        © Copyright 2016 TRENDnet. All Rights Reserved.      4   ...
  • Page 9: System Function

      TFC‐1600MM  TRENDnet User’s Guide                     System Function  There are five items in System Function menu, “Software Reboot, Factory Reset, Image Update, Save Configuration and Configuration Update.       Software Reboot  Reboot the management module in order to run the new setting properly.        © Copyright 2016 TRENDnet. All Rights Reserved.      5   ...
  • Page 10: Factory Reset

      TFC‐1600MM  TRENDnet User’s Guide                     Factory Reset  This function is to set the device back to the default setting in case of the messy setting. There are two functions in Factory Reset page:   Chassis Factory Reset: for all modules factory reset.  CPU Reset: only this control module factory reset.  Image Update  The section is to set the TFTP Server IP Address first and the Image File name as you store in the TFTP Server. The Image File can be updated by uploading the image file from the TFTP  server.  Note: The content of the image file will write the whole firmware of the management module, please be sure that the image file is correct.    Save Configuration  The section is to save the change on the flash to make sure all configuration settings is permanent.      © Copyright 2016 TRENDnet. All Rights Reserved.      6   ...
  • Page 11: Configuration Update

      TFC‐1600MM  TRENDnet User’s Guide                     Configuration Update  The section is explaining how to upload and download the configure setting of the module.  The Configuration Upload is to restore a setting file to the management module.  The Configuration Download is to backup the setting from the management module.    © Copyright 2016 TRENDnet. All Rights Reserved.      7   ...
  • Page 12: Configuration

      TFC‐1600MM  TRENDnet User’s Guide                     Configuration  There are five items in Configuration menu, General Configuration, System Configuration, SNMP Configuration, Location Setting and Redundant Backup Setting.  General Configuration  Hardware revision: noted the version of the Media Converter Chassis.  BIOS revision: noted the version of the BIOS.  Firmware revision: noted the version of the firmware.  Old Password: the Old of the admit password.  Change Password: the changing of the admit password.  Confirm Password: to confirm the setting of admit password.  System Name: to authorize the device system name.  Location: to show the Media Converter Chassis where it is located.  Refresh time: to set the refreshing time of the device through the web.  Note: After configuring the system device, need to press the save button to save the setting.      © Copyright 2016 TRENDnet. All Rights Reserved.      8   ...
  • Page 13: System Configuration

      TFC‐1600MM  TRENDnet User’s Guide                     System Configuration  MAC Address: will show out the MAC address of the Management Module.  IP Address: to allocate an IP address for the Management Module, the default IP is “192.168.1.1”.  Subnet Mask: to set the Subnet Mask, the default is 255.255.255.0”.  Default Gateway: to set the gateway address, the default is “0.0.0.0”. (0.0.0.0 Means no default gateway address)  Note: After configuring the system device, need to press the save button to save the setting.            © Copyright 2016 TRENDnet. All Rights Reserved.      9   ...
  • Page 14: Snmp Configuration

      TFC‐1600MM  TRENDnet User’s Guide                     SNMP Configuration      Get Community Name: to get the device community name (default = public).  Set Community Name: to set the device community name (default = private).  Trap Community Name: to authorize the device trap community name (default = public).  Trap Host IP Address: to set the trap host IP address (same as monitoring station IP address).  Cold Start trap: to set the trap for rebooting the device (default = disable).  Warm Start trap: to set the trap when the device had been reset (default = disable).  Authentication Fail Trap: to set the warning trap when the community name of the device and workstation are different (default = disable).  Power Fail Trap: to set the Power Fail Trap (default = enable).  Fan Fail Trap: to set the Fan fail trap (default = enable).  MC Plugin Trap: to set the trap when a Media Converter Module has been plugged in (default = enable).  MC Pullout Trap: to set the trap when the Media Converter Module has been pulled out (default = enable).  MC Broken trap: to set the trap when the Media Converter Module was broken (default = enable).  MC Link up trap: to set the trap when a linking is connected (default = enable).  MC Link down trap: to set the trap when a linking is disconnected (default = enable).  MC Active Slot Xchg trap: to set the trap when there is a redundant function activated (default = enable).  MC Active Slot Lose trap: to set the trap when the redundant function is fail (default = enable).    © Copyright 2016 TRENDnet. All Rights Reserved.      10   ...
  • Page 15: Converter Location Setting

      TFC‐1600MM  TRENDnet User’s Guide                     Converter Location Setting  Allocating each slot’s location in order to remember in where each slot was connected.    Redundant Backup Setting  The redundant function is to change the master line to the slave line in case of the linking fails happen.  The Redundant functions were set fixed, the master slot is slot 1(odd number slot) and the slave slot is slot 2(even number slot), and there are eight redundant groups in all. The “Act”  will indicate what slot is active.  When Master slot link fail, slave slot will be enabled. When the slave slot is activated, we need to transfer again to the master slot, and we need to check the “Restart” box on the group  then click “Save” button.  The redundant function depends only on some Smart Media Converters.        © Copyright 2016 TRENDnet. All Rights Reserved.      11   ...
  • Page 16: Configure Your Module (Command Line Interface)

      TFC‐1600MM  TRENDnet User’s Guide                     Configure your Module (Command Line Interface) Console and Terminal Emulator program settings  The Media Converter Chassis Management Module can be accessible using a terminal or terminal emulator attached to the RJ‐45 UTP console port.   Serial port configuration cable:  One end of the cable is a DB9 serial port, which connects to serial port on computer. Other end is an RJ‐45 UTP port, which connects to the SNMP Media Converter Chassis.  To configure the Hyper Terminal of the management PC via serial port configuration cable to manage the Media Converter Chassis.  By default, the Media Converter Management Module uses the following serial port parameter values:   Bits per second    115200   Stop bits      1   Data bits    8   Parity      NONE   Flow Control ...
  • Page 17   TFC‐1600MM  TRENDnet User’s Guide                     Reboot  COMMANDS  reboot    Factory Reset  reset  COMMANDS  cpureset  reset: for all modules factory reset.  cpureset: only this control module factory reset.    Image Update  COMMANDS  update <ipaddr> <path_filename (64)>  The <ipaddr> is to set the TFTP Server IP Address first and <path_filename (64)> is the Image File name as you store in the TFTP Server.     General Configuration  config system passwd  config system name <string 31>  COMMANDS  config system location <string 31>  config system refreshtime {never | 10secs | 30secs | 1min | 5mins}  show system  The “refreshtime” is to set the refreshing time of the device through the web.  IP interface configuration  config ipif system ipaddress <ip_addr> <ip_mask> [<ip_addr>]  COMMANDS ...
  • Page 18   TFC‐1600MM  TRENDnet User’s Guide                     SNMP Configuration  config snmp get_communityname [<community_string (31)>]  config snmp set_communityname <community_string (31)>  config snmp trap_communityname <community_string (31)>  config snmp trap_hostip <ipaddr>  config snmp coldstart_trap {enable | disable}  config snmp warmstart_trap {enable | disable}  config snmp authfail_trap {enable | disable}  config snmp powerfail_trap {enable | disable}  COMMANDS  config snmp fanfail_trap {enable | disable}  config snmp mcplugin_trap {enable | disable}  config snmp mcpullout_trap {enable | disable}  config snmp mclinkup_trap {enable | disable}  config snmp mclinkdown_trap {enable | disable}  config snmp mcbroken_trap {enable | disable}  config snmp mcactiveslotXCHG_trap {enable | disable}  config snmp mcactiveslotLOSE_trap {enable | disable}  show snmp    © Copyright 2016 TRENDnet. All Rights Reserved.      14   ...
  • Page 19   TFC‐1600MM  TRENDnet User’s Guide                     SNMP Configuration commands:  config snmp get_communityname: to configure the “get” community name (default = public).  config snmp set_communityname: to configure the “set” community name (default = private).  config snmp trap_communityname: to configure the “trap” community name (default = public) for authorize the device trap.  config snmp trap_hostip: to set the trap host IP address (same as monitoring station IP address).  config snmp coldstart_trap: to set the trap for rebooting the device (default = disable).  config snmp warmstart_trap: to set the trap when the device had been reset (default = disable).  config snmp authfail_trap: to set the warning trap when the community name of the device and workstation are different (default = disable).  config snmp powerfail_trap: to set the Power Fail Trap (default = enable).  config snmp fanfail_trap {enable | disable}: to set the fan fail trap (default = enable).  config snmp mcplugin_trap {enable | disable}: to set the trap when a Media Converter module has been plugged in (default = enable).  config snmp mcpullout_trap {enable | disable}: to set the trap when the Media Converter module has been pulled out (default = enable).  config snmp mclinkup_trap {enable | disable}: to set the trap when a linking is connected (default = enable).  config snmp mclinkdown_trap {enable | disable}: to set the trap when a linking is disconnected (default = enable).  config snmp mcbroken_trap {enable | disable}: to set the trap when the Media Converter module was broken (default = enable).  config snmp mcactiveslotXCHG_trap {enable | disable}: to set the trap when there is a redundant function activated (default = enable).  config snmp mcactiveslotLOSE_trap {enable | disable}: to set the trap when the redundant function is fail (default = enable).            © Copyright 2016 TRENDnet. All Rights Reserved.      15   ...
  • Page 20   TFC‐1600MM  TRENDnet User’s Guide                     CPU module information  show mediaconverter chassis COMMANDS Media Converter Configuration  show mediaconverter status  COMMANDS  config mediaconverter slot <integer (1‐16)> ([name <string (7)>] [Device_LLCF {v|x}] [Device_Enable {v|x}] [M1_LLR {v|x}] [M1_Auto {A|F}] [M1_Speed  {10M|100M|1G}] [M1_Dup {F|H}] [M1_FC {v|x}] [M1_Enable {v|x}] [M2_LLR {v|x}] [M2_Auto {A|F}] [M2_Dup {F|H}] [M2_Enable {v|x}])  Media Converter Configuration command (Some of the function can be control only depends on the Smart Media Converter Modules):      {v|x}, V stands for “yes” and X stands for “No”. {A|F}, “A” for Auto‐Negotiation or “F” for “forced Mode”.  {10M|100M|1G}, to select the speed of the copper port, “10M”, “100M” or “1G”  {F|H}, “F” for Full Duplex or “H” for Half Duplex        © Copyright 2016 TRENDnet. All Rights Reserved.      16   ...
  • Page 21   TFC‐1600MM  TRENDnet User’s Guide                     Redundant Backup Setting  show mediaconverter redundant  COMMANDS  config mediaconverter redundantgrp <integer (1‐8)> ([{enable|disable}] [restart])  The redundant function is to change the master line to the slave line in case of the linking fails happen.   The Redundant functions were set fixed, the master slot is slot 1(odd number slot) and the slave slot is slot 2(even number slot), and there are eight redundant groups in all. The “Act”  will indicate what slot is active.  The redundant function depends only on some Smart Media Converters.  Redundant Backup Setting commands:  show mediaconverter redundant:  show master slot or slave slot is active.  config mediaconverter redundantgrp <integer (1‐8)>  [restart]: When Master slot linking fails happen, slave slot will be enabling; user can process this command change the active slot  (slave slot) back to the master slot.   config mediaconverter redundantgrp <integer (1‐8)>  [enable|diable]: There are eight redundant groups can be enable or disable when those Smart Media Converters support the  redundant function.  Configuration  save config COMMANDS System Function  clear show command_history COMMANDS logout      ...
  • Page 22: Technical Specifications

      TFC‐1600MM  TRENDnet User’s Guide                      Chassis Reset  Technical Specifications  Standards  Converter Module Monitoring    IEEE 802.3  Link Status    IEEE 802.3u  Slot Occupied    IEEE 802.3x  Revision    IEEE 802.3ab  Converter Type   Part Number  Device Interface   Line card interface for TRENDnet TFC‐1600 slot only  SNMP Controls ...
  • Page 23   TFC‐1600MM  TRENDnet User’s Guide                     MTBF   2,709,617 hours  Operating Temperature   0 – 40°C (32 ‐ 104°F)  Operating Humidity   Max. 90% non‐condensing  Dimensions   128 x 35 x 88 mm (5.04 x 1.38 x 3.46 in.)   2U height (for TRENDnet TFC‐1600 chassis slot only)  Weight   108 g (3.8 oz)  Certifications   CE   FCC        © Copyright 2016 TRENDnet. All Rights Reserved.   ...
  • Page 24: Appendix

      TFC‐1600MM  TRENDnet User’s Guide                     Note: If you are experiencing difficulties, please contact your computer or operating  Appendix  system manufacturer for assistance.  How to find your IP address?     Note: Please note that although the following procedures provided to follow for your  How to configure your network settings to use a static IP address?  operating system on configuring your network settings can be used as general  Note: Please note that although the following procedures provided to follow for your  guidelines, however, it is strongly recommended that you consult your computer or  operating system on configuring your network settings can be used as general  operating system manufacturer directly for assistance on the proper procedure for  guidelines, however, it is strongly recommended that you consult your computer or  configuring network settings.  operating system manufacturer directly for assistance on the proper procedure for    configuring network settings.  Command Prompt Method    Windows 2000/XP/Vista/7/8.1/10  Windows 7/8.1/10  1. On your keyboard, press Windows Logo+R keys simultaneously to bring up the Run  a. Go into the Control Panel, click Network and Sharing Center.  dialog box.  b. Click Change Adapter Settings, right‐click the Local Area Connection icon.  2. In the dialog box, type cmd to bring up the command prompt.  c. Then click Properties and click Internet Protocol Version 4 (TCP/IPv4). ...
  • Page 25   TFC‐1600MM  TRENDnet User’s Guide                     In MAC OS 10.4, from the Show drop‐down list, select Built‐in  How do I use the ping tool to check for network device connectivity?  Ethernet and select the TCP/IP tab.  Windows 2000/XP/Vista/7/8.1/10  In MAC OS 10.5/10.6, in the left column, select Ethernet.   1. On your keyboard, press Windows Logo+R keys simultaneously to bring up the Run  e. Configure TCP/IP to use a static IP.  dialog box.  In MAC 10.4, from the Configure IPv4, drop‐down list, select Manually  2. In the dialog box, type cmd to bring up the command prompt.  and assign your network adapter a static IP address. Then click the  Apply Now button.  3. In the command prompt, type ping <ip_address> with the <ip_address> being the IP  In MAC 10.5/10.6, from the Configure drop‐down list, select Manually  address you want ping and check for connectivity.  and assign your network adapter a static IP address . Then click the  Example: Usage of ping command and successful replies from device.  Apply button.   C:\Users>ping 192.168.10.100  f. Restart your computer.  Pinging 192.168.10.100 with 32 bytes of data:    Reply from 192.168.10.100: bytes=32 time<1ms TTL=64  Note: If you are experiencing difficulties, please contact your computer or operating  Reply from 192.168.10.100: bytes=32 time<1ms TTL=64  system manufacturer for assistance.  Reply from 192.168.10.100: bytes=32 time<1ms TTL=64 ...
  • Page 26   TFC‐1600MM  TRENDnet User’s Guide                     Federal Communication Commission Interference Statement  RoHS  This equipment has been tested and found to comply with the limits for a Class B digital device,  This product is RoHS compliant.   pursuant  to  Part  15  of  the  FCC  Rules.  These  limits  are  designed  to  provide  reasonable    protection against harmful interference in a residential installation. This equipment generates,    uses and can radiate radio frequency energy and, if not installed and used in accordance with  the instructions, may cause harmful interference to radio communications. However, there is    no guarantee that interference will not occur in a particular installation. If this equipment does   ...
  • Page 27   TFC‐1600MM  TRENDnet User’s Guide                     TRENDnet tímto prohlašuje, že tento TFC‐1600MM je ve shodě se  Šiuo TRENDnet deklaruoja, kad šis TFC‐1600MM atitinka esminius   Česky [Czech]  Lietuvių  základními požadavky a dalšími příslušnými ustanoveními směrnice  [Lithuanian]   reikalavimus ir kitas 2011/65/EU, 2014/35/EU, 2014/30/EU,  2011/65/EU, 2014/35/EU, 2014/30/EU, 2004/108/ES a 2006/95/ES.  2004/108/EB ir 2006/95/EB Direktyvos nuostatas.  Undertegnede TRENDnet erklærer herved, at følgende udstyr TFC‐ Dansk [Danish]  Hierbij verklaart TRENDnet dat het toestel TFC‐1600MM in  Nederlands  1600MM overholder de væsentlige krav og øvrige relevante krav i  overeenstemming is met de essentiële eisen en de andere relevante  [Dutch]  direktiv 2011/65/EU, 2014/35/EU, 2014/30/EU, 2004/108/EF og  bepalingen van richtlijn 2011/65/EU, 2014/35/EU, 2014/30/EU,  2006/95/EF.  2004/108/EG en 2006/95/EG.  Hiermit erklärt TRENDnet, dass sich das Gerät TFC‐1600MM in  Deutsch  Hawnhekk, TRENDnet, jiddikjara li dan TFC‐1600MM jikkonforma mal‐ Malti [Maltese]  Übereinstimmung mit den grundlegenden Anforderungen und den  [German]  ħtiġijiet essenzjali u ma provvedimenti oħrajn relevanti li hemm fid‐...
  • Page 28   Limited Warranty  TRENDnet User’s Guide                     In the event that, after evaluation, TRENDnet cannot replace the defective product or  Limited Warranty  there is no comparable model available, we will refund the depreciated value of the  TRENDnet warrants only to the original purchaser of this product from a TRENDnet  product.  authorized reseller or distributor that this product will be free from defects in material    and workmanship under normal use and service. This limited warranty is non‐ If a product does not operate as warranted during the applicable warranty period,  transferable and does not apply to any purchaser who bought the product from a  TRENDnet shall reserve the right, at its expense, to repair or replace the defective  reseller or distributor not authorized by TRENDnet, including but not limited to  product or part and deliver an equivalent product or part to the customer. The  purchases from Internet auction sites.  repair/replacement unit's warranty continues from the original date of purchase. All    products that are replaced become the property of TRENDnet. Replacement products  Limited Warranty  may be new or reconditioned. TRENDnet does not issue refunds or credit. Please  contact the point‐of‐purchase for their return policies.  TRENDnet warrants its products against defects in material and workmanship, under  normal use and service. Specific warranty periods are listed on each of the respective    product pages on the TRENDnet website.   TRENDnet shall not be responsible for any software, firmware, information, or memory  data of customer contained in, stored on, or integrated with any products returned to  ...
  • Page 29   Limited Warranty  TRENDnet User’s Guide                     shipping from outside of the USA and Canada are responsible for any return shipping  CONTRACT OR TORT (INCLUDING NEGLIGENCE), FOR INCIDENTAL, CONSEQUENTIAL,  and/or customs charges, including but not limited to, duty, tax, and other fees.  INDIRECT, SPECIAL, OR PUNITIVE DAMAGES OF ANY KIND, OR FOR LOSS OF REVENUE OR  PROFITS, LOSS OF BUSINESS, LOSS OF INFORMATION OR DATE, OR OTHER FINANCIAL    LOSS ARISING OUT OF OR IN CONNECTION WITH THE SALE, INSTALLATION,  Refurbished product: Refurbished products carry a 90‐day warranty after date of  MAINTENANCE, USE, PERFORMANCE, FAILURE, OR INTERRUPTION OF THE POSSIBILITY  purchase. Please retain the dated sales receipt with purchase price clearly visible as  OF SUCH DAMAGES, AND LIMITS ITS LIABILITY TO REPAIR, REPLACEMENT, OR REFUND  evidence of the original purchaser's date of purchase. Replacement products may be  OF THE PURCHASE PRICE PAID, AT TRENDNET'S OPTION. THIS DISCLAIMER OF LIABILITY  refurbished or contain refurbished materials. If TRENDnet, by its sole determination, is  FOR DAMAGES WILL NOT BE AFFECTED IF ANY REMEDY PROVIDED HEREIN SHALL FAIL  unable to replace the defective product, we will offer a refund for the depreciated value  OF ITS ESSENTIAL PURPOSE.  of the product.      Governing Law: This Limited Warranty shall be governed by the laws of the state of  WARRANTIES EXCLUSIVE: IF THE TRENDNET PRODUCT DOES NOT OPERATE AS  California.  WARRANTED ABOVE, THE CUSTOMER'S SOLE REMEDY SHALL BE, AT TRENDNET'S    OPTION, REPAIR OR REPLACE. THE FOREGOING WARRANTIES AND REMEDIES ARE  EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, ...
  • Page 30        ...

Table of Contents