1. Product Summarize U1000E, U1000F, U2000E, U2000F is a new generation of RFID UHF series products for our company's independent research and development of the long distance RFID Standalone Terminal in the parking lot and access control system. The product uses the industry's most cost-effective UHF card reader chip, and the part of swing card adopts the module integrated design, making the product to meet the technical requirements of the parking lot and access control system.
6PIN Green 6PIN Black 4PIN Green 4PIN Black 3. Parameters Specifications Model U1000E,U1000F U2000E,U2000F Logo&Color ZKTeco logo, black (standard)/White logo, white(optional) Card Capacity 5000 cards Log Capacity 30,000 Transactions Reading Distance 0-6m(Stable is 0-5meters) 0-12m(Stable is 0-10meters) Communication TCP/IP ,USB,Wiegand26/34...
4. Safety Precautions 1) The Standalone Terminal working voltage ranges from DC9V to DC16V, it is recommended to use DC12V /3A power supply. 2) Please wire according to the cable definition. 5. Modifying Setting via Demo 1) USB Connection Standalone Terminal 2) Software Introduction Our company provides Demo, used to set the working parameters of the Standalone Terminal.
Page 6
The default configuration of the Standalone Terminal is as follows: Work Mode Always Read Read Tag Interval Time 0s (Default) Wiegand Out Setting wiegand 26; Forward Output; 9th Start Byte(Default); Wiegand Interval Time 2s (Default) Output Power 18dBm~26dBm 902MHz ~928MHz (American Standard); Working Frequency 865MHz ~ 868MHz (European standard) Demo Using Instructions:...
18~26dBm. Wiegand Setting: Set the machine's wiegand output format. Setting Wiegand Out Bytes: Sets the forward or reverse output of the machine's Wiegand Data, and start output from the first few bytes. Read Tag Interval Time: Set the machine to read the card interval. Read card interval is the time when from the card is read within the scope of the card to the card is left out of the scope of the card to read the second time card.
Page 8
Add Device After searching, select the Standalone Terminal and click [Add Device], and a dialog box will open. Enter self-defined device name, device type set to Standalone Device and click [OK] to complete device adding. Note: The default IP address of the Standalone Terminal may conflict with the IP of a device on the Internet.
Page 9
Set Access Control Parameters The Access Control Parameters include time zones, holidays, door settings, access levels, anti-passback, personnel group, multi-card opening and so on. For more details about how to set the access control parameters, please see the software user manual. Sync All Data to Device Select device, click [Synchronize All Data] and click [OK] to complete synchronization.
6.2. Access to ZKBioSecurity The procedure to access to ZKBioSecurity is basically the same as 6.1. Access to ZKAccess; for more details, please see the software user manual. 7. Solution Long Distance Access Control Management Compared with the traditional access control close proximity recognition mode, long distance access control gets rid of the passive recognition of the shackles, really realize the “Hand Free”...
Page 11
This solution provide user with a non-stop, no card, quick access to parking lots experience. The system consists of U2000 series Standalone Terminal, UHF tag3 (installed on the upper or lower edges of the license plate) or tag4 (pasted on the interior windshield of car), and parking barrier. When the car pulls up the range of the U2000 Standalone Terminal, the authorized tag mounted on car will be identified, then reading information is transmitted to the Standalone Terminal, after identification correctly, Standalone Terminal outputs an “open”...
U2000 Standalone Terminal connect with parking barrier 8. Note The Standalone Terminal cannot be installed in a high-voltage environment, for example, high tension wires and high-voltage transformers. The Standalone Terminal cannot be installed near strong magnetic field. If the Standalone Terminal is installed at a T-junction or a 90°...