Scott AIR-PAK 75i 2.2 Operating & Maintenance Instructions page 43

Industrial pressure-demand self contained breathing apparatus (scba)
Table of Contents

Advertisement

S—SPECIAL OR CRITICAL USER'S INSTRUCTIONS
ALL MODELS ARE APPROVED ONLY WHEN COMPRESSED AIR CYLINDER IS FULLY CHARGED WITH AIR MEETING THE REQUIRE-
MENTS OF THE COMPRESSED GAS ASSOCIATION SPECIFICATION G-7.1, GRADE D AIR OR EQUIVALENT SPECIFICATIONS, OR
MEETING CE EUROPEAN STANDARD EN 132. THE CONTAINER SHALL MEET APPLICABLE DOT SPECIFICATIONS.
EXCEPT AS NOTED HEREIN, ALL MODELS OF THE SCOTT 2.2 OR 4.5 ARE APPROVED FOR RESPIRATORY PROTECTION DUR-
ING ENTRY INTO OR ESCAPE FROM OXYGEN DEFICIENT ATMOSPHERES, GASES AND VAPORS, AT TEMPERATURES ABOVE
-25° F / -32° C.
MASK SEAL KIT P/N 805655-01 IS REQUIRED IF A USER SEAL CHECK IS UNSATISFACTORY EITHER PER THE USER INSTRUC-
TIONS OR THE OSHA FIT TESTING PROCESS. THE MASK SEAL KIT IS PROVIDED WITH THE FULL FACEPIECE. THIS IS A NIOSH
APPROVED COMPONENT TO ENHANCE THE FIT OF THE FACEPIECE.
WHEN USING FACEPIECE P/N 803921-01, 803921-02, OR 803921-03 AT TEMPERATURES BELOW 32° F / 0° C, USE THE OPTIONAL
NOSE CUP ASSEMBLY P/N 802819-01.
THE SCOTT COMMUNICATIONS DEVICES CAN ONLY BE USED WITH SCOTT FACEPIECES FITTED WITH DUAL VOICEMITTERS
SUCH AS THE AV-2000 OR AV-3000.
Page 43 of 44
P/N 595236-01 Rev. B 10/11