General Bell Box Wiring
As with the detector wiring we would suggest that you adopt a standard for your Bell Box wiring,
the colour scheme below is provided as a suggestion only.
Hold Off Supply +................. Red
Hold Off Supply - .............. .. Black
Trigger................................... Blue
Tamper Return...................... Yellow
Strobe +................................ Green
Strobe -................................. White
Bell Tamper Ring
It should be noted that many bell boxes that are fitted with rechargable batteries will sound when
the battery is connected. This connection may take the form of manually connecting the battery
wires to terminals or placing a link into the On position. Dependant on the bell box being used
the sounder may sound when the battery is connected unless power from the control panel is
connected or the bell box tamper is closed or in some cases both. Most bell boxes produce
high volume noise adequate ear protection MUST be used.
Sample Bell Box Connections
Below is shown general and sample bell box connections for some of the popular bell boxes that
are available.
Fig.6A
eurosec control
panel terminals
SAB TMP
Bell Hold -
Bell -
Bell +
Strobe -
Strobe +
Fig.6C
eurosec control
panel terminals
SAB TMP
Bell Hold -
Bell -
Bell +
Strobe -
13:14
Page 6
a a
n n
u u
a a
l l
a a
n n
u u
a a
l l
General bellbox
connections
Tamper Feed
Tamper Return
Supply -
Bell Trigger
Supply +
Strobe -
Strobe +
Check bellbox
terminal positions
Delta E, Novagard 1E & 6
bellbox connections
TMP-F
R-TMP
0V
S-
12V+
ST-
Check bellbox
terminal positions
Fig.6B
eurosec control
panel terminals
SAB TMP
Bell Hold -
Bell -
Bell +
Strobe -
Fig.6D
eurosec control
panel terminals
SAB TMP
Bell Hold -
Bell -
Bell +
Strobe -
Strobe +
P P
a a
g g
e e
6 6
P P
a a
g g
e e
6 6
e e
u u
r r
o o
s s
e e
c c
e e
u u
r r
o o
s s
e e
c c
Novagard Delta
bellbox connections
TMPR
0V
Bell SW-
12v
STR SW-
Check bellbox
terminal positions
Novagard 2&4
bellbox connections
F Tamper Feed
R Tamper Return
-12v Supply
Bell SW-
+12v Supply
Strobe -
Strobe +
Check bellbox
terminal positions