Page 3
Hardware Installation Guide For Europe This drive is in conformity with the EMC directive. Federal Communications Commission (FCC) Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. Those limits are designed to provide reasonable protection against harmful interference in a residential installation.
Hardware Installation Guide Welcome to Hardware Installation Guide. This guide is designed to be used as step-by-step instructions for installation of your subsystem, and covers everything you need to know in learning how to operation, troubleshooting and future upgrades. For the detail about how to configure your subsystem, please refer to the Software Operation manual.
PCI-E 8X 24 bays AN-716E8N PCI-E 8X 16 bays AN-712E8N PCI-E 8X 12 bays The Alnico Series RAID Subsystem is designed to meet today’s high volume, performance storage requirements from rapidly changing business environment. It provides a maximum data protection and exceptional performance in a storage subsystem.
Page 8
Hardware Installation Guide PCI-E Gen3 x 8 as Host 6Gbps SAS / 6Gbps SATA backplane supported. RAID Levels : 0, 1,1E, 3, 5, 6, 50, 60 & JBOD. Multiple RAID selection. Online RAID level/stripe size migration. Online Array roaming. Globe and dedicated Hot Spare Disk / Pass through Disk support. Disk Scurbbing/Array verify scheduling.
Chapter 1. Introduction Understanding the Alnico RAID subsystem Front Panel Overview LCD Module Function keys. ( ENT, ESC, Scroll up, Scroll Down ) Keys Descriptions Up Arrow To scroll upward through the menu items Down Arrow To scroll downward through the menu items To confirm a selected item (ENT ) Enter (ESC) ESC...
Page 10
Hardware Installation Guide LED Indicator Normal Status Problem Indication Bright Blue This LED does not light up after Power On indicator power switched on Fail Indicator LED never light up LED light up as Red. Data Access Blink blue during host computer LED never flickers accessing the RAID subsystem.
Page 11
Chapter 1. Introduction Drive Bay Lock LED Indicator Blue : HDD Power on Key Lock Flash : Accessing Unlock LED Indicator Handle Red : HDD Error Release Button...
Hardware Installation Guide Rear Panel Overview AN-724E8N PCIe-SAS/SATA RAID SUBSYSTEM 6 11 10 12 PCIe 8X Connector Colors Indicate Green Link Blue + Blink Access SAS Expand Port SAS Expand Port LED Indicator ( Link / Access ) Colors Indicate Green Link Blue + Blink...
Page 13
Chapter 1. Introduction Battery back up module Power Switch FAN Module /FAN Module 1 FAN failure indicator (Rear / Front) 10. FAN Module /FAN Module 1 latch FAN Module 2 12. FAN failure indicator (Rear / Front) 13. FAN Module 2 latch 14.
Page 14
Hardware Installation Guide SAS Expand Port SAS Expand Port LED Indicator ( Link / Access ) Colors Indicate Green Link Blue + Blink Access Raid Controller Status LED & Fault LED Indicator Colors Indicate Status Green + Blink Raid Controller OK Fault Raid Controller Fault LAN port...
Page 15
Chapter 1. Introduction AN-712E8N PCIe-SAS/SATA RAID SUBSYSTEM 6 10 2. PCIe 8X Connector Colors Indicate Green Link Blue + Blink Access SAS Expand Port SAS Expand Port LED Indicator ( Link / Access ) Colors Indicate Green Link Blue + Blink Access Raid Controller Status LED &...
Page 16
Hardware Installation Guide FAN Module 2 10. FAN failure indicator (Rear / Front) Power Module 1 12. AC inlet 1 & Ltch 13. Power Module 2 14. AC inlet 2 & Latch...
Chapter 2. Installation This chapter presents: & & & & & & Before unpacking the Alnico RAID subsystem, prepare a clean, stable surface to put on the contents of RAID shipping container. Altogether, you should find following items in the package: PCIe to SAS/SATA RAID Subsystem : RAID subsystem x1 CD-ROM x 1 ( Includes Hardware Installation Guide, Software operation...
Hardware Installation Guide Dedicated terminal or PC with third party communication software that supports ANSI terminal emulation (required for viewing Monitor Utility) Use a suitable anti-static wrist or ankle strap and observe all conventional ESD precaution when handle Alnico RAID’s modules and components. Avoid contact with backplane components and module connectors.
Chapter 2. Installation Place drive bays back into the system 1. Slide in drive bay, make sure the handle is open fully. 2. Close the handle to engage the drive bay into the slot. The hard drives in a RAID array should match in size and speed. All drives in any array should be identical models with the same firmware versions.
Hardware Installation Guide To install the PCIe repeater card, remove the mounting screw and existing bracket from the rear panel behind the selected PCIe slot. Align the gold-fingered edge on the card with the selected PCIe expansion slot. Press down gently but firmly to ensure that the card is properly seated in the slot. Then, screw the bracket onto the computer chassis.
Page 21
Chapter 2. Installation Figure 1. Place the Alnico Subsystem into the rack 1. Lift the subsystem enclosure and slide it slowly and gently along the slide rail into the rack as Figure 2. Figure 2. 2. Fasten two M5 screws through the chassis ears in the front side of the...
Hardware Installation Guide chassis to secure the Alnico subsystem in the rack as Figure 3. Figure 3. The Alnico subsystem is heavy, two person are required to move the system in the procedure. Connect all cables and power cord as shown below : Cable Alnico RAID Device...
Chapter 2. Installation RJ 45 Cable Ethernet Port Switch or HUB Connect to Internet. Mini SAS Cable SAS Expander Port Raid System Connect to SAS Expander There are many topologies of SAS JBOD with Alnico Gen 2 RAID subsystems. Ways to implement are as below: One SAS Raid subsystem with one SAS JBOD 16Bays Fibre RAID 16bays JBOD...
Page 24
Hardware Installation Guide 16Bays Fibre RAID 16bays JBOD 16bays JBOD 16bays JBOD 16bays JBOD It supports up to four tiers and 256 drives. One RAID Set supports up to 32 HDDs One SAS Raid subsystem supports up to 128 Volumes One SAS Raid subsystem supports up to 256 HDDs There are four tiers within JBOD topology as above: First tier is a RAID System.
Chapter 2. Installation 1. It is often recommended to install the hard drive with same brand, model no., interface and capacity in this RAID subsystem. 2.Please do not install SAS and SATA hard drives at the same time, as these hard drives spin at different speed and may lead to compatible issues or performance decline.
Hardware Installation Guide This chapter contains trouble shooting procedures and suggestions to minimize their impact on the Alnico RAID operation : If the fault LED on the front panel and LCD of Alnico RAID lights red and LCD displays a error message , or if Alnico RAID’s Internet manager indicates a fault, determine the reason for this alert immediately.
Chapter 3. Trouble Shooting Removing the controller from Alnico AN-712 RAID : In order to access controller box, 1. Turn anti-clock wise to release the thumb Screws. 2. Push down the use eject bar to remove controller box. Installing the controller into Alnico RAID: Reverse the procedure of “removing the controller”...
Hardware Installation Guide Installing DIMM To install a DIMM, ensure the system power is off and disconnected. Then: 1. Turn anti- lock wise to release two thumb screws, then use the eject bar to remove controller box, then open the cover. 2.
Page 29
Chapter 3. Trouble Shooting Removing the Fan Module from AN-716 and AN-724 : Remove the Fan modules by slide the release button left and pull the module out of system. push Pull out Replace the Fan in Fan module 1. There are two failure LEDs on the rear of Fan module.
Hardware Installation Guide 5. There are two failure LEDs on the rear of Fan module. Check which LED lights to yellow. 6. Remove modules anti-clock wise to release the thumb screw then slide it back and lifting off. 7. Release the screw to remove the defect fan.
Hardware Installation Guide The external RAID controller operates using cache memory .The battery Backup Module is an add-on module that provides power to the external RAID controller cache memory in the event of a power failure. The Battery Backup Module monitors the write back cache on the external RAID controller, and provides power to the cache memory if it contains data not yet written to the hard drives when power failure occurs.
Page 35
Appendix B. Battery Back up Module Install Battery board ( ARC-8006-2) into controller’s J7 connector, location is shown as bellowing : Insert the 3pin Connector into Battery Board’s ( ARC8006-2) JA2 connector. Install the BBM and fasten 4 screws.on BBM carrier. Plug in the BBM’s connector into socket on carrier...
Hardware Installation Guide Plug the BBM carrier into the controller and fasten the thumb screws. Battery Backup Capacity Battery backup capacity is defined as the maximum duration of a power failure for which data in the cache memory can be maintained by the battery. The BBM’s backup capacity varied with the memory chips that installed on the external RAID controlle Capacity...
Appendix B. Battery Back up Module Operation Battery conditioning is automatic. There are no manual procedures for battery conditioning or preconditioning to be performed by the user. Battery bad a tendency to “remember” its capacity. In order to make sure of all the capacity of your battery cells, allow the battery cell to be fully charged when installed for the first time.
Page 38
Hardware Installation Guide Alnico AN-7 RAID Series AN-724E8N AN-716E8N AN-712E8N Model Controller Number Single Single Single 800Mhz Dual Core RAID-On-Chip Storage Processor. Advanced PCI-Express 3.0 x8 bus Up to 8GB DDR3-1333 SDRAM on one DIMM socket with architecture RAID ECC protection.
Appendix C. Specification AN-724E8N AN-716E8N AN-712E8N Model Firmware-embedded Web browser-based RAID manager via built-in 10/100 Ethernet. Firmware-embedded manager through front LCD control panel. RAID Management Firmware-embedded manager via RS-232 port. Field-upgradeable firmware in flash ROM. All system status can be monitored by firmware-embedded Web browser-based RAID manager.