Page 3
Hardware Installation Guide For Europe This drive is in conformity with the EMC directive. Federal Communications Commission (FCC) Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. Those limits are designed to provide reasonable protection against harmful interference in a residential installation.
Page 4
Hardware Installation Guide Welcome to Hardware Installation Guide. This guide is designed to be used as step-by-step instructions for installation of your subsystem, and covers everything you need to know in learning how to operation, troubleshooting and future upgrades. For the detail about how to configure your subsystem, please refer to the Software Operation manual.
/ Dual 10Gb iSCSI as Host interface per controller, each with 12, 16, or 24 device bays. Model Host Interface Device bays Controller Numbers Name AN-824STS 2 x miniSAS HD 24 bays 1 ( Upgradeable, Up to 2) AN-824FQS 4 x 16Gbps FC 24 bays...
Page 8
Hardware Installation Guide AN-812FHS 2 x 16Gbps FC 12 bays 1 ( Upgradeable, Up to 2) AN-812iGS 2 x 10Gb iSCSI 12 bays 1 ( Upgradeable, Up to 2) AN-825STS 2 x miniSAS HD 24 bays 1 ( Upgradeable, Up to 2) AH-825FQS 4 x 16Gbps FC 24 bays...
Chapter 1. Introduction Support spin down drivers when not in use to extend service life (MAID). Instant availability and background initialization. Automatic drive insertion / removal detection and rebuilding. Understanding the Alnico RAID subsystem Front Panel Overview LCD Module Function keys.
Page 10
Hardware Installation Guide (ENT ) Enter To confirm a selected item (ESC) ESC To exit a sub-menu and return to previous menu. There are three LED indicators on the front panel. Following table provides a summary of the meanings of these LED indicators: LED Indicator Normal Status Problem Indication Bright Blue...
Page 12
Hardware Installation Guide Lock LED Indicator Blue : HDD Power on Key Lock Flash : Accessing Unlock LED Indicator Handle Red : HDD Error Release Button Drive Bay for AH Series Lock Unlock Latch LED Indicator Blue: HDD Power on LED Indicator Flash: Accessing Red: HDD Error...
Page 14
16 17 18 12 14 2 15 19 20 21 7 10 1. Controller Box 1. 2. Controller Box 2 AN-824STS/D: SAS CH 1 & LED Indicator SAS CH 0 & LED Indicator Colors Indicate Green Link Blue + Blink...
Page 15
Chapter 1. Introduction Colors Indicate Green 16 Gbps Link Amber 8 Gbps Link Green+Amber+Blink 4 Gbps Link Blue + Blink Access AN-824FHS/D: FC_CH_1 & LED Indicator FC_CH_0 & LED Indicator Colors Indicate Green 16 Gbps Link Amber 8 Gbps Link Green+Amber+Blink 4 Gbps Link Blue + Blink...
Page 16
Hardware Installation Guide 11. Console 12. Terminal 13. LAN port 14. Battery back module (Option) 15. Power Switch 16. FAN failure indicator (Rear / Front) 17. FAN Module 1 18. FAN Module 1 latch 19. FAN failure indicator (Rear / Front) 20.
Page 18
Hardware Installation Guide 1. Controller Box 1. 2. Controller Box 2 AN-816STS/D: SAS CH 1 & LED Indicator SAS CH 0 & LED Indicator Colors Indicate Green Link Blue + Blink Access AN-816FQS/D: FC_CH_3 & LED Indicator FC_CH_2 & LED Indicator FC_CH_1 &...
Page 19
Chapter 1. Introduction AN-816iGS/D: iSCSI_CH_1 & LED Indicator iSCSI_CH_0 & LED Indicator Colors Indicate iSCSI Green 10 Gbps Link Amber 1 Gbps Link Blue + Blink Access 7. Raid Controller Status LED & Fault LED Indicator Colors Indicate Status Green + Blink Raid Controller OK Fault Raid Controller Fault...
Page 21
Chapter 1. Introduction 16 17 5 6 20 15 18 7 10 11 12 13 14 1 1. Controller Box 1. 2. Controller Box 2 AN-812STS/D: SAS CH 1 & LED Indicator AH-825STS/D: SAS CH 0 & LED Indicator Colors Indicate Green Link...
Page 22
Hardware Installation Guide Green 16 Gbps Link Amber 8 Gbps Link Green+Amber+Blink 4 Gbps Link Blue + Blink Access AN-812iGS/D : iSCSI_CH_1 & LED Indicator AH-825iGS/D : iSCSI_CH_0 & LED Indicator Colors Indicate Green 10 Gbps Link Amber 1 Gbps Link Blue + Blink Access 7.
Page 23
Chapter 1. Introduction 18. FAN failure indicator (Rear / Front) 19. FAN Module 2 20. AC inlet 1 & Latch 21. Power Module 1 22. AC inlet 2 & Latch 23. Power Module 2...
Hardware Installation Guide This chapter presents: & I g & & c I I I & g & & c Before unpacking the Alnico Gen 2 RAID subsystem, prepare a clean, stable surface to put on the contents of Alnico Gen 2 RAID shipping container.
Hardware Installation Guide The Alnico Gen 2 RAID series includes 12/16/24 hot swappable drive bays. The following sections describe how to install disks into Alnico RAID subsystems. Loading 2.5” Hard Disk to the drive bay. (for AN Series) 1. Put 2.5 HDD into the bay. 2.
Page 27
Chapter 2. Installation The hard drives in a RAID array should match in size and speed. All drives in any array should be identical models with the same firmware versions. RAID arrays can use any size drive, however the smallest drive will determine the size of the array.
Page 28
Hardware Installation Guide You are shipped one rackmounting kit for each Alnico subsystem that you intend to rackmount. Alnico subsystem is designed for installation into a industry-standard 19-inch rackmount cabinet. Following the use of this section for installing the Alnico subsystem into a Rack Install the Slide Rails 1.
Page 29
Chapter 2. Installation Place the Alnico Subsystem into the rack 1. Lift the subsystem enclosure and slide it slowly and gently along the slide rail into the rack as Figure 2. Figure 2. 2. Fasten two M5 screws through the chassis ears in the front side of the chassis to secure the Alnico subsystem in the rack as Figure 3.
Hardware Installation Guide The Alnico subsystem is heavy, two person are required to move the system in the procedure. Connect all cables and power cord as shown below: Cable Alnico RAID Device Purpose Serial Cable Terminal Port Configuration Utility ANSI Terminal or PC with Terminal emulator.
Chapter 2. Installation There are many topologies of SAS JBOD with Alnico Gen 2 RAID subsystems. Ways to implement are as below: One SAS Raid subsystem with one SAS JBOD 16Gb Fibre RAID 12Gb SAS JBOD One SAS Raid subsystem with more SAS JBODs 16Gb Fibre RAID ...
Page 32
Hardware Installation Guide It supports up to four tiers and 256 drives. One RAID Set supports up to 32 HDDs One SAS Raid subsystem supports up to 128 Volumes One SAS Raid subsystem supports up to 256 SAS devices There are four tiers within JBOD topology as above: ...
Page 33
Chapter 2. Installation When cabling is completed, RAID SYSTEM can be turned on. This should be done in the following order: 1. First turn on the power switch of JBODs. 2. Then turn on the power switch of RAID SYSTEM. 3.
Hardware Installation Guide This chapter contains trouble shooting procedures and suggestions to minimize their impact on the Alnico RAID operation : I If the fault LED on the front panel and LCD of Alnico RAID lights red and LCD displays a error message, or if Alnico RAID’s Internet manager indicates a fault, determine the reason for this alert immediately.
Chapter 3. Trouble Shooting Removing the controller from Alnico 2U 12bays & 2U24Bay RAID : In order to access controller box, 1. Turn anti-clock wise to release the thumb Screws. 2. Push down the use eject bar to remove Controller box. Installing the controller into Alnico RAID: Reverse the procedure of “removing the...
Hardware Installation Guide Installing DIMM To install a DIMM, ensure the system power is off and disconnected. Then: 1. Turn anti- lock wise to release two thumb screws, then use the eject bar to remove controller box, then open the cover. 2.
Chapter 3. Trouble Shooting This section provides instructions for the removal and installation of the Fan Module indicated in the figure below. Removing the Fan Module from Alnico 16bays and 24bays subsystems : Remove the Fan modules by slide the release button left and pull the module out push Pull out...
Hardware Installation Guide Removing the Fan Module from Alnico 2U 12bays & 24Bay RAID subsystems : Remove the Fan modules by slide the release button left and pull the module out of system, push Pull This section provides instructions for the removal and installation of the Power Module indicated in the figure below.
Appendix B. Battery Back up Module Ethernet RJ-45 Connector Pin# Signal Name Fibre SFP Pin# Signal Name FAULT MOD_DEF(2) MOD_DEF(1) MOD_DEF(0) Rate Select...
Page 40
Hardware Installation Guide RJ-11 Pin# Signal Pin# Signal miniSAS HD (SFF-8644)
Hardware Installation Guide The external RAID controller operates using cache memory .The battery Backup Module is an add-on module that provides power to the external RAID controller cache memory in the event of a power failure. The Battery Backup Module monitors the write back cache on the external RAID controller, and provides power to the cache memory if it contains data not yet written to the hard drives when power failure occurs.
Page 43
Appendix B. Battery Back up Module Install Battery board ( ARC-8006-2) into controller’s J7 ( AN-6)/J8 (AN-7) connector, location is shown as bellowing : Insert the 3pin Connector into Battery Board’s ( ARC8006-2) JA2 connector. Install the BBM and fasten 4 screws.on BBM carrier. ...
Page 44
Hardware Installation Guide Plug the BBM carrier into the controller and fasten the thumb screws. Battery Backup Capacity Battery backup capacity is defined as the maximum duration of a power failure for which data in the cache memory can be maintained by the battery. The BBM’s backup capacity varied with the memory chips that installed on the external RAID controller Capacity...
Page 45
Appendix B. Battery Back up Module Operation Battery conditioning is automatic. There are no manual procedures for battery conditioning or preconditioning to be performed by the user. Battery bad a tendency to “remember” its capacity. In order to make sure of all the capacity of your battery cells, allow the battery cell to be fully charged when installed for the first time.
Page 46
Hardware Installation Guide Specifications Alnico AN-8 RAID Series AN-824 AN-816 AN-812 Model 824STS/D 824FQS/D 824FHS/D 816STS/D 816FQS/D 816FHS/D 812STS/D 812FQS/D 812FHS/D Controller Up to 2 Up to 2 Up to 2 Number 1.2Ghz RAID-On-Chip Dual-Core Storage Processor. Advanced PCI-Express 3.0 bus architecture. Up to 8GB DDR3-1866 ECC RDIMM (Registered Default cache memory size: 2GB RAID...
Page 47
Appendix C. Specification AN-824 AN-816 AN-812 Model 824STS/D 824FQS/D 824FHS/D 816STS/D 816FQS/D 816FHS/D 812STS/D 812FQS/D 812FHS/D Firmware-embedded Web browser-based RAID manager via built-in 10/100 Ethernet. Firmware-embedded manager through front LCD control panel. RAID Management Firmware-embedded manager via RS-232 port. Field-upgradeable firmware in flash ROM. All system status can be monitored by firmware-embedded Web browser-based RAID manager.
Page 48
Hardware Installation Guide Alnico AH-8 RAID Series AH-825 Model 825STS/D 825FQS/D 825FHS/D Controller Up to 2 Up to 2 Up to 2 Number 1.2Ghz RAID-On-Chip Dual-Core Storage Processor. Advanced PCI-Express 3.0 bus architecture. Up to 8GB DDR3-1866 ECC RDIMM (Registered Default cache memory size: 2GB RAID DIMM) on one socket.
Page 49
Appendix C. Specification AH-825 Model 825STS/D 825FQS/D 825FHS/D Firmware-embedded Web browser-based RAID manager via built-in 10/100 Ethernet. Firmware-embedded manager through front LCD control panel. RAID Management Firmware-embedded manager via RS-232 port. Field-upgradeable firmware in flash ROM. All system status can be monitored by firmware-embedded Web browser-based RAID manager. Firmware-embedded SNMP agent allows the remote to monitor events with no SNMP agent required.