User Guide A Mobile Worker Safety Device Complementing Loner Mobile SureSafe™ Alert. Locate. Respond. Safety Monitoring confirmation light...
Page 3
RF Exposure Statement / Déclaration d’exposition RF For body worn operation, Loner Duo has been assessed for RF exposure and meets the requirments of FCC KDB447498 and IC RSS-102. / Pour utilisation sur le crops, Loner Duo a été évalué pour l’exposition aux RF et répond aux exigences de la FCC KDB447498 et IC RSS-102.
Safety Precautions Blackline takes your safety and the safety of those around you very seriously. It is important for you to be aware of the following precautions. DANGER Do not place a Blackline Product in or near an open flame or in the presence of flammable gases or fumes.
Page 7
Do Not operate Blackline products outside their specified operating temperature. § Consult the specifications section. Do Not store Blackline products outside their specified storage temperature. § Consult the specifications section. Do Not operate Blackline products outside their specified humidity rating. Consult §...
Bluetooth® to a smartphone operating the Loner Mobile safety monitoring app. This guide provides information that you will find helpful to comfortably operate your Loner Duo. The unit contains the following internal components: Bluetooth Smart v4.0 Radio...
Requirements Loner Duo promotes a safe work environment for you when: Bluetooth communication has been established with the smartphone § running Loner Mobile. Loner Duo and the smartphone both have sufficient battery capacity § to operate. You are wearing the device and keep the associated smartphone within §...
Using the Loner Duo Loner Duo Hardware Details Loner Duo is rugged and purpose-built for monitoring you as a mobile worker. Physical details are outlined below. Physical Feature SureSafe™ Power Button Powers Loner Duo and indicates the network and/or & Indicator Light Bluetooth connection status.
Page 11
Indicator Light Array Power Button & Indicator Light Acknowledge Button (push) Emergency Latch Charging Light (pull) (on bottom) Belt Clip Product Label Charging Port...
USB symbol on the cable faces the flat side of the charging clip. Slide the charging clip onto Loner Duo using the guides to align the clip with the Charging Port on the device. Completely charge Loner Duo for two hours.
Select the "Scan for Loner Duo Devices Now" button. Once the app has finished searching for devices, select the Loner Duo from the list that corresponds to the Unit ID on the Product Label on the back of the device.
Monitoring Infrastructure. It will flash green when the app is not monitoring, or when Loner Duo is not connected to the app. Wear Loner Duo on your belt at your hip at all times that you require safety monitoring. Perform your work duties as you normally would. Loner Duo automates remote monitoring of your safety.
Loner Duo Light Behaviour Loner Duo features a SureSafe Indicator Light and a Red Charging Light. Please see below for the light behaviour. Light Behaviour SureSafe Indicator Light Red Charging Light Light Flashing Indicates Loner Duo is Indicates Loner Duo powered and not connected is charging.
Alerts Alert messages are configured for Loner Mobile and Loner Duo through the Loner Portal web application. Alerts are displayed in Loner Portal and can be sent via email and SMS to safety monitoring personnel. Alerts An alert is a message that communicates a device or system level event such as an Emergency Alert or a Low Battery Alert.
If you are in an emergency situation, perform the following: Open the Emergency Latch. Loner Duo will annunciate the high alarm pattern to notify others nearby of the event. Loner Duo will instantly send an Emergency Message to Loner Mobile.
Push and hold the Acknowledge Button for 10 seconds. Loner Duo will vibrate for 5 seconds, pause and then vibrate for 5 more seconds. A Silent Emergency Message will be sent to Loner Mobile. Loner Duo will NOT annunciate the alarm pattern (it will remain silent).
About Activity/Motion Monitoring Loner Duo is constantly monitoring your motion. If Loner Duo has not detected motion as per your configuration, it will enter the alarm mode and annunciate the low alarm pattern to indicate a pending No-motion alert. If you do not require assistance, you have 30 seconds to cancel the alert.
About Low Battery Detection Loner Duo monitors its battery level of the device. If the battery level drops below 20% of battery capacity, a Low Battery Alert will be sent to monitoring personnel and Loner Duo will annunciate the low battery alarm pattern. This feature is configurable in Loner Portal.
Specifications Specifications for Loner Duo Software Compatibility Power & Battery Loner Mobile Version 1.2 or higher for iOS, Android and Rechargeable Li-ion battery: 350 mAh capacity Battery life: 20 hours continuous operation Blackberry Charging connector: 4-pin sealed connection Size & Weight Environmental Size: 51 mm W x 32 mm H x 62 mm L (2.01”...
Loner Duo Care Considerations Regarding Use and Storage of Loner Duo Loner Duo meets IP65 ingress protection ensuring that under normal operation no dirt or water can enter the device. Storage temperature range of: -30 to 75°C (-22 to 167°F).