Page 1
TAUD-40 POWER AMPLIFIER ADVENTURES BROADCASTING...
Page 2
No? Okay, good. Please take a few minutes to read the manual and familiarize yourself with your new Technalogix power amplifier. We believe that this manual, and of course our equipment, should be everything you need to get on the air with superb broadcast quality video.
Section I - Safeguards General Safeguards This section is written as a general guide to keep all 5 fingers on your hand and is intended for those having previous knowledge and experience with these kinds of equipment. It is not intended to contain a complete statement of all safety precautions, which should be observed by personnel using this or other electronic equipment.
Safety and First Aid Personnel engaged in the installation, operation, maintenance, or servicing of electronic equipment are exposed to the hazard of high voltage. It is imperative that all safety regulations and precautions are consistently observed. Knowledge of first aid procedures is recommended. The following information is presented as a reference only.
Operating Safeguards It is a known fact that our broadcast transmitters and translators enjoy 50-ohm load impedances. So much so, that it is imperative you maintain 50-ohm impedances throughout your system. In return, your equipment will provide you with maximum power transfer to the antenna and decreased reflected power heading back towards the amplifier pallets, reducing the amount of magic smoke that gets let out of the power amplifier.
Technalogix Ltd. will not be liable for damages of whatever nature arising out of or in connection with the equipment or its use thereof. Technalogix does not assume responsibility for injury or damage resulting from the practices of untrained or unqualified personnel in the handling of this equipment.
Page 9
If a solution cannot be found at this time, it may be determined that the unit will have to be returned to Technalogix for repair, once a Return Materials Authorization (RMA) number is provided. Please look under our web site (www.technalogix.ca) for the RMA form (Service) and fill it out.
Section III - Overview Standard Features • No sync compression to ensure power amplifier is digital compatible • Narrow output bandpass filter allows adjacent channel operation • Front panel Liquid Crystal Display (LCD) to monitor forward and reflected RF power, and DC voltage •...
The TAUD-40 power amplifier is a modular solid-state 100-watt broadcast amplifier utilizing readily available RF components wherever possible, thus enhancing the serviceability of the equipment.
Block Diagram The RF signal enters through the RF Input connector on the power amplifier enclosure from the modulator or processor. It then passes through an RF attenuator to limit the output power level of the power amplifier and to help buffer any transients that may come into the power amplifier. After attenuation, the signal is amplified through the UHFTV-10 driver and UHFTV-150 final pallet before the signal passes through an isolator (circulator with load) and a bandpass filter.
Page 13
UHFTV-150 DIRECTIONAL CIRCULATOR COUPLER Attenuator RF INPUT RF OUT TO WATTMETER AND ANTENNA A=-0.05dB typ. A=-0.4dB typ. Adjustable A=+38dB min to +49 dB max A=-0.4dB to -0.6dB 50-OHM TERMINATION TAUD-40 Block Diagram Date: June 27, 2005 Page: 1 of 1...
Page 14
3.6Aac at 115Vac, 1.8Aac at 230Vac at 25W ps TAUD-20 4Aac at 115Vac, 2Aac at 230Vac at 50W ps TAUD-40 7Aac at 115Vac, 3.5Aac at 230Vac (TAUD-40) at 100W ps TAUD-80 6Aac at 230Vac at 250W ps TAUD Series Issue 1.02...
Page 15
Operating temperature 0 to +45°C Humidity 90% non-condensing Built in components UHF bandpass filter and RF isolator included Due to continuous product improvements, Technalogix reserves the right to change specifications without notice. Internal View Typical Block Diagram BANDPASS RF OUTPUT FINAL...
Section IV – RF Components Amplifier Pallets The UHFTV-10 pallet is a two stage ultra linear class-A linear pallet. It has an adjustable gain of 26dB to 37dBand draws no more than 5.o Adc total drain current (the exact bias and drain currents of your system are found in the spec sheet supplied with each manual).
Directional Coupler The Technalogix dual directional couplers provide DC voltages proportional to forward and reflected RF power monitoring. These analog voltages are converted for processing using analog-to-digital converters and provide the control system with valuable data for monitoring purposes. The directional...
Section V – Power Supply Switching AC-DC power supplies are used to power the amplifier pallets, the control circuits, and all of the fans. There is (1) power supply used to generate the necessary current for the amplifier pallets, set to 31.0 Vdc nominally.
Page 21
SWS300/600 Series Single Output General Purpose Power Supplies Low Cost Active Power Factor Correction Universal Input (85 - 265VAC) Input Transient Protected IEC61000-4 SEMI F47 Certified (208VAC Input) K e y M a r k e t S e g m e n t s & A p p l i c a t i o n s Factory Automation Process Control, NC-Machining, Automotive, Packaging Equipment,...
Page 22
SWS300/600 Series M o d e l S e l e c t o r S W S 3 0 0 O u t l i n e D r a w i n g Load Line Ripple Adjust Curr. Noise Eff.(3) VR FOR Vadj.
Section VI – Monitor and Control System Control System Overview (Insight) The Insight control system is used for a variety of functions, the most important of which is ensuring that the transmitter continues to operate in a safe manner. The control system also allows the user to monitor and control the transmitter from both the front panel and the remote access port.
monitored by U101 to U105, buffered by U106 to U108, and sent to the analog to digital converter integrated into the microcontroller. There are five circuits for which the current is monitored by this system. As the DC supply passes through the user interface module, it undergoes filtering to ensure that the supply to the pallets is as clean as possible.
RF Conditioning Module The RF conditioning board is located at the RF input of the amplifier. Its main function is to act as a variable attenuator, so that the control system can add attenuation to the input of the amplifier in order to limit the output power of the transmitter.
Remote Port The remote port allows external control of the transmission system via the DB25. The functions of each pin on the remote port are indicated in the following table: Pin Number Description Ground Forward power sample Reflected power sample Carrier off Carrier on Increase carrier level (level must have been decreased)
Fault Shutdowns On the LCD (Liquid Crystal Display) the following messages may appear: If you see this message, the system has been driven to a power level higher than it is rated for. This message will likely only appear momentarily, before the amplifier will add attenuation at its input to bring the output power to a safe level.
Page 43
Coupler Conditioning Module +3.3 Vdc Remote Access Port U205 MOCD211M +5 Vdc CAR OFF U206 MOCD211M CAR ON OVERDRV VSWR R203 R204 R205 R206 J203 J204 U207 MOCD211M CAR DOWN CAR UP U208 MOCD211M TEMP R207 R208 R209 R210 U209 MOCD211M RFL-OUT FWD-OUT...
Page 47
Temperature Sensor DRV DIS LM70 TMP SO TMP SCK TMP GND TMP VCC TMP CS TMP VCC N. Hendrickson, A. Sivacoe Temperature Sensor Board 1.02 Insight Control System Date: May 8, 2005 Page: 1 of 1...
Page 48
J601 PSUflag F601 RFL samp TEMPflag F602 J602 FWD samp VSWRflag ODRVflag ground J603 CAR on CAR off CAR up F603 +5 Vdc CAR down F604 +3.3 Vdc Soft RES RESET J604 J605 IN 1 OUT 1 IN 2 OUT 2 IN 3 OUT 3 IN 4...
Section VII – Mechanical Section The heat sink allows the amplifiers to operate at a cooler temperature and prevents overheating, which helps the longevity of the entire system. The heat sink has hollow fins, which help dissipate the heat from the amplifiers faster than a conventional serrated or corrugated fin. In addition to the cooling effects of the heat sink, there is a fan that provides 110 cubic feet per minute (CFM) of air flow (into zero static pressure).
A sloping roof will tend to develop leaks less rapidly. The building should be well roofed with good material. The cooling load will be lowered with reflective or light colored roofing material. Technalogix Ltd VIII-1...
The environment’s temperature will contribute greatly to the length of the power amplifier’s life. Technalogix recommends that the building’s filtered air intake must have capacity for all air-flow in the building plus an additional 20%. Keep the intake below the roofline to avoid intake of solar heated air.
• You are apt to get better overall support if you give what business you can to local suppliers Technalogix recommends that proper AC line conditioning and surge suppression be provided on the primary AC input to the power amplifier. All electrical service should be installed with your national electrical code in your area, any applicable provincial or state codes, and good engineering practice.
Technalogix provides complete turnkey antenna systems if needed. If your site is serving as a translator, your receiving antenna should be in line of sight to the originating station all year round.
Check the soil runoff conditions that may slow or hasten wind or water erosion and other concerns that may be unique to your location. Technalogix Ltd VIII-5...
Claims for loss or damage may not be withheld from any payment to Technalogix, nor may any payment due be withheld pending the outcome thereof. Technalogix cannot guarantee the carrier’s performance.
Location and Function of Controls and Connectors (TAUD-40 Power Amplifier) The following illustration depicts the location of the connectors when installing the power amplifier (TAUD-40). Technalogix Ltd VIII-7...
Page 57
AC ON/OFF - AC rocker switch (SPST) to supply AC to the AC-DC switching power supply REMOTE PORT - The transmitter can be controlled and monitored by the remote port. See “Monitor and Control System” section for details. Technalogix Ltd VIII-8...
8. Ensure that the video modulation level is set to 87.5% with the video signal supplied, as described in the appropriate modulator/processor manual (will be factory set). 9. Connect the transmitting antenna cable to the RF OUT N -type connector on the power amplifier enclosure RF output. Technalogix Ltd VIII-9...
TAUD-40 power amplifier is ready to receive a properly modulated video and audio signal, proceed with the following steps to place the system in operation. The TAUD-40 power amplifier has been factory aligned for channel frequency (per system specification), signal levels and optimum performance.
Page 60
10. The TAUD-40 LCD shows the user the present status of the amplifiers. Adjust RF output power to desired level (see Important RF Power Notice in previous section). Verify that the FWD Power reads 100% or less - depending on signal content. The output power level can be adjusted using the modulator or processor’s RF output level adjust.
Section X – Maintenance and Troubleshooting Periodic Maintenance If your unit employs a filter on the air inlet for the fans, the filter should be cleaned every 30 days. If the equipment is operated in a severe dust environment, the filters on the inlet fan may need to be cleaned more regularly.
Troubleshooting The first and most important aspect of troubleshooting anything is to be systematic. Note where you have looked and what you found. Look first for the obvious. • Make a physical inspection of the entire facility. Are all necessary connections properly made? Do you see any signs of obvious damage within the equipment? •...
Page 63
Symptom Possible Fault Correction Weak output or picture Low level input signal Verify presence and level of input signal Low output power Verify power amplifier output with wattmeter and dummy load Incorrect modulation depth Adjust to meet specification High reflected power Incorrect load Ensure amplifier connected to transmission line...
Need help?
Do you have a question about the TAUD-40 and is the answer not in the manual?
Questions and answers