Air King LE600A Instructions And Operating Manual page 3

Table of Contents

Advertisement

Available languages

Available languages

2
When there is access to the top of the unit, connect the ducting to the duct collar and
secure in place using tape to seal all joints (Figure 4).
3.
When there is no access to the top of the hood, carefully pull down the metal duct through
the custom hood base hole. Slide this duct over the duct collar. Make sure the adapter/
damper assembly enters the ducting. Seal the connection with duct tape.
NOTE: To achieve proper air flow, 10" round ducting is required. The duct connector is 9.8"
in diameter (for 10" round ducting). To ensure the best air and sound performance, it is
recommended that the length of ducting and the number of elbows be kept to a minimum,
the radius of each elbow be as large as possible for the installation, and that hard ducting be
used. Larger duct sizes will reduce noise and airflow restrictions.
CAUTION:
ALWAYS DUCT THE FAN TO THE OUTSIDE THROUGH A
WALL OR ROOF CAP.
SECTION 6
Wiring
CAUTION:
IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR NATIONAL
ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL
WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN.
3
Examine the wire compartment cover and select the most convenient wire entrance
and remove the knock out. Feed the supply wire through the opening and install an
appropriate strain relief. Connect the two loose White wires from the range hood to the
White wire from the supply, and the loose Black wire from the range hood to the Black
wire of the supply. Connect the ground wire (green or bare) from the supply to the green
ground screw of the hood. Use approved methods for all connections (Figure 6).
Black
Neutral (White)
Neutral (White)
Green
Figure 6
2.
Attach the wire compartment to the power unit with two of the provided #6 blunt tipped
screws (Figure 7).
Figure 7
SECTION 7
Setting the speed control
(Models LE600A only)
1.
Your range hood is equipped with a
speed control that allows the hood to
run continuously at the preset CFM
level. To set the CFM level, move the
rotary dial located inside the wire
compartment to the desired CFM.
2.
Locate the rocker switch labeled "ASHRAE 62.2" on the speed control cover and make
sure it is in the ON position. To turn the continuous speed function off, set the switch to
the OFF position.
WARNING:
SWITCH TO THE OFF POSITION DOES NOT TURN THE MAIN POWER TO
THE HOOD OFF.
6727921 Rev. C 11-17
ALL ELECTRICAL CONNECTIONS MUST BE MADE
Black
Neutral (White)
Ground (Green or Bare)
Wire Compartment
30
ON
OFF
SWITCHING THE CONTINUOUS SPEED ROCKER
SECTION 8
Motorized Damper
An optional motorized damper can be connected to the
unit. The damper is connected via a 24V transformer
that plugs into the receptacle in the unit (Figure 8).
Power Supply Requirements: 120V/60Hz/Max 15W
NOTE: Receptacle to be used ONLY for Air King
motorized damper.
NOTE: Make sure to reference the instructions
included with the motorized damper before
installing or operating.
Operation
1.
When installed the outlet will be energized
anytime the unit is set to high, medium or low
speed. When the speed control is set to off
the damper will close.
SECTION 9
Finishing the Installation
1.
Remove any protective plastic adhered to the power unit.
2.
Install lamps by inserting lamp into socket and turning clockwise slightly until firmly
seated. DO NOT over tighten.
LE600A, LE600: Two GU10 Base 7W maximum LED lamps
L600: Two GU10 Base 50W maximum Halogen lamps
3.
Turn switches to the OFF ( • ) position and restore power. Test that the light and the fan
are operating properly.
4.
If there is any vibration noise, check for the source and try to tighten fasteners, adjust
the tape to make a tighter connection or seal, or check that the hood collar damper, wall
damper or ceiling damper are opening properly.
SECTION 10
Operation
Controls
Your Range Hood is equipped with two rotary switches with one controlling the lighting and
the other controlling the exhaust fan blower. The light switch is a dimmer switch. The fan
switch has four positions, Off, High, Medium, and Low (Figure 9).
Figure 9
SECTION 11
Maintenance
CAUTION:
SERVICE PANEL BEFORE SERVICING THE UNIT.
Filters
1.
Included with your unit are aluminum grease filters that should be washed at least once
a month. The filters are should be washed in a mild soap or detergent.
2.
To remove the filters, pull down on the handle tab until the filter releases from the unit. To
50
reinstall, slide tab at rear of filter into slot in the unit. While holding in handle of filter, lift
filter into place and release handle. The filter should snap securely into place (Figure 10).
70
90
Figure 10
3.
If the grease filters become damaged, replace with the Air King Model SVGF-03 Grease Filters.
www.airkinglimited.com
Receptacle
Figure 8
MAKE SURE POWER IS SWITCHED OFF AT
Tab
3 of 12