Specifications; Maintenance; Warranty; Upgrade - BQT Solutions Cobalt YD30 Installation And Operating Instructions Manual

Table of Contents

Advertisement

8. SPECIFICATIONS

MATERIALS
Bolt Pins
Strike Plate
Lock Face Plate
MECHANICAL
Cycle life
Strike Gap
Holding Force
Door Misalignment
ELECTRICAL
Voltage at Lock
Current Usage
Monitor Switches
CERTIFICATIONS
Patent
FCC
CE
*
Initial power up of the lock requires up to 1800mA@12VDC and up to 600mA@24VDC for up to 6 seconds but only occurs
when the power has been completely removed and re-applied.
Normal Operating Current after initial power up is <250mA@12VDC and <200mA@24VDC.

9. MAINTENANCE

The COBALT has been lubricated at assembly and applying any other type of lubricant may void the warranty.
Removing the lock cover may void the warranty. A dry cloth can be used to polish the stainless steel face plate and
strike plate as required.

10. WARRANTY

The COBALT is covered with a manufacturers 12month warranty against faulty or malfunctioning parts,
components or product. At the manufacturer's discretion, either a replacement lock or affected part will be supplied
to remedy the fault or the lock can be returned at the customer's expense to the manufacturer for repair.
Mistreatment or ill-use of the lock may void the warranty. YNOTLOC and COBALT are trademarks of Magna
Electronics Pte Limited. Magna Electronics Pte Limited will not be liable for any direct, indirect, incidental or
consequential loss or damage in any way related to this product.

11. UPGRADE

The COBALT is designed and manufactured by Magna Electronics Pte Limited. Magna Electronics Pte Limited
reserves the right to upgrade or change this product without prior notice.
For more information visit www.ynotloc.com
© Magna Electronics Pte Ltd.
SS17-4PH, 10mm Thick, 13mm stroke (2 Pieces)
SS304, 3mm Thick
SS304, 3mm Thick
> 100,000
< 8mm
> 10,000N (1000kg)
±8mm
12 – 24VDC ±15%
Standby Current
< 50mA@12V
*
Operating Current
< 1800mA@12V
Bolt position – 30VDC, 0.1A
Door position – 100VDC, 0.5A
Pending NZ599955
Part 15 Subparts A & B – Unintentional Radiators
EN 61000-6-1: 2007, EMC Directive 2001/108/EC Immunity
EN 61000-6-3: 2007, EMC Directive 2001/108/EC Emissions
< 30mA@24V
< 600mA@24V