Linkage Setup; Alarm Output - OOSSXX 6-in-1 DVR & DVR Security System Owner's Manual

Video security system
Table of Contents

Advertisement

11.1.5 Time interval
In the interval of time setup (default 1 second), for example, multiple motion detect only trigger an
alarm signal.

11.2 Linkage setup

Linkage setup is to deal with motion setup after alarm.

11.2.1 Alarm output

When motion detect occurs, set up corresponding linkage alarm output port of the external equipment
(such as alarm), external alarm to produce the corresponding reaction equipment, after alarm output port
should choose, some equipment is one output port, some are two, please note which one you want to
choose. When the color turn black it is selected, otherwise it is not selected.
The【Delay】which behind of 【Alarm output】is the continuous time of the alarm output after alarm
triggered. the default time is 10s. Users can accord their own demands to set.
11.2.2
Recording channel
The recording channel function is when motion detect in this channel, it will record motion detective in
the channel which be selected, and then record as a file type for the M recording file. The choosing of
recording channel could be one to one, also can be one to-many Channel corresponding box be black is be
selected, otherwise it is not selected, below picture is the channel setup, channel 1(one to one), channel
1(one to-many). Generally suggest user choose one to one type.
One to one: when generate an alarm in this channel, only linkage this channel to recording. For
example, picture (1), when channel 1 generates an alarm, corresponding channel will generate linkage
recording, and packaged a M recording profile.
One to-many: when generate an alarm in this channel linkage the channel you choose to recording,
see below picture, when channel 1 generates an alarm, linkage the channel (2,4, 6, 8, 10, 12, 14, 16) to
record, packaged a M type recording profile.