Before operating your Air
Purifier, please read this
user manual carefully and
retain the manual for
future reference.
USER'S GUIDE
AIR PURIFIER
Contents
Safety Information
Safety Instructions
0
HexaDuo
Page
1
2
3
3
4
6
8
10
11
12

Advertisement

loading

Summary of Contents for Nectar HexaDuo

  • Page 1: Table Of Contents

    USER’S GUIDE AIR PURIFIER HexaDuo Contents Page Safety Information Features Packing List Components Operations Instructions Clean and Maintenance Before operating your Air Purifier, please read this Trouble Shooting user manual carefully and retain the manual for Safety Instructions future reference.
  • Page 2 Thank you for purchasing HexaDuo. The HexaDuo is easy to use, and helps to produce a clean and safe environment. It is an energy-efficient high performance air purifier with patent HIRD technology to help build a green life style. Safety Instructions: WARNING: ...
  • Page 3: Features

    Features  Simple to use.  Energy Star compliance – highly efficient air cleaning with low operating cost.  5 fan speed and mute selections for quiet but high performance operation.  Remove dust and pollutants in the air.  Sophisticated measures to ensure safe operations;...
  • Page 4: Packing List

    Packing List Components...
  • Page 5: Operations

    Operations Buttons / Indicators Descriptions Button Silent Fan Speed Indicators Button Silent Operation Modes Warning Description Indication When the accumulated operation ①Cleaning mode time reach two weeks, the Cleaning Indicator will be lights up to remind user clean collection array. Press the flashing Cleaning button...
  • Page 6 collection array to clean. Clean and dry the collection array before re-install back to the device. ②Protection mode When the device is operating, and the collection array is removed suddenly, then the device will be stop working, and all Indicators will flash at the same time as an alert to user.
  • Page 7: Instructions

    Instructions 1. Connect the adaptor and manage the power cord. Note: Leave about 1ft (0.3m) behind and a free path way in the front to allow unobstructed air flow for best performance. 2. Turn on the unit.
  • Page 8 NOTE: You may hear static noise when the unit is first started. This is normal due to setting up of the hyper ionic field for capturing the airborne particles. 3. Adjust the required speed. 4. Stretch the bipod of the unit and put the unit on a flat table or floor.
  • Page 9: Clean And Maintenance

    Clean and Maintenance 1. Power off the unit and pull down the lock button to unlock and then remove the collection array from the unit. 2. For strong or sticky oil type pollutant, using spray soft cleaner and use cleaning tool to clean the individual dust plate and mesh cover.
  • Page 10 3. Immerse the whole collection array into water or rinse it thoroughly under running water. 4. Dry the collection array before re-install that to the unit. Re-install the collection array in vertical direction down and it will locked by lock button, HexaDuo will be resume to normal operation.
  • Page 11: Trouble Shooting

    Note: Continue using the unit for 2 weeks, lights up to alert you to clean the collection array. Press the flashing button for 3sec to acknowledge the cleaning alert. Both Cleaning indicator & cleaning mode indicators will be turn off. Power Off the unit and take out collection array to clean.
  • Page 12 Safety Information   Do not use outdoors. Do not use as a toy.   Do not use damaged Do not repair the unit by adaptor or plug. yourself.   Do not handle the adaptor Do not use in wet places. or device with wet hands.
  • Page 13: Specification

    Specifications Input: 100-240V, 50/60Hz Power Adaptor Output: DC 15V, 1.5A CADR 180+ Suggested Room Area 450-550sq.ft 9.4” (W) x 5.9” (D) x 15.7” (H) Dimensions Weight 9.36 LBS Operating Temperature 0 to 40 deg.C Storage Temperature -10 to 60 deg.C Operating Humidity Less than 90% The above specifications are only for reference.
  • Page 14 directrice (2010) de Santé Canada recommande un niveau maximal d'exposition, basé sur un moyen de 8 heures, soit 0,020 ppmv ou moins dans une chambre de teste étanchée et contrôlée de 30 m³.  Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.