Download Print this page

Samsung MG7980W Owner's Instructions Manual page 8

Hide thumbs Also See for MG7980W:

Advertisement

FUSE
250V20A
BLK
BLK
POWER CORD
AC 120V/60Hz
WHT
MGT
TCO
NOTE: CIRCUIT SHOWN WITH DOOR IS OPENED POSITION.
NOTE: FOR SERVICE REPLACEMENT USE 16 GA 105 C
THERMOPLASTIC COVERED WIRE EXCEPT
FOR HIGH VOLTAGE LEADS OR AS NOTED ON SPECIAL LEADS.
MG7980W Schematic Diagrams
CAVITY
PRIMARY S/W
TCO
BLK
BLK
BLK
BLK
130V
L
40W
BLK
YEL
WHT
WHT
WHT
BLK
BLU
ORG
120V
COM
FM
DM
21V
NC
0V
YEL
ORG
WHT
WHT
POWER RELAY
(SECONDARY INTERLOCK)
1. INPUT : 120V 60HZ
2. DOOR : OPEN
3. LAMP : ON
4.
: P.C.B PATTERN
5.
: P.C.B IN/OUT POINT
WARNING
POWER MUST BE DISCONNECTED
BEFORE SERVICING THIS APPLIANCE
H. V. TRANSFORMER
120V
BLK
H. V. CAPACITOR
NO
F
FA
0V
MAGNETRON

Advertisement