Pipe installation

Heat pump must always be connected with a fixed PVC pipe Ø50 or a bypass kit (recommended by Pahlén ).
The pipes may need to be relieved, so that the connections do not have too much burden (breakout force can damage the
heat exchanger).
Any tightening of the coupled connections to the heat pump should be made by hand (tools can damage connections).
To protect the heat pump from dirt and snow it is optimal to place it on a base or stand above the ground level.
NOTE! The pipe length between the pump and the pool should not be more than 10 meters.
Install the supplied drain connection down through the holes in the heat pump's base. Connect it to the following drainage hose
and make sure that wastewater and condensate are drained from the heat pump.
1. Skimmer
2. Main drain
3. Inlet
4. JetSwim
5. Light
6. Circulation pump
7. Filter
8. Heat pump
9. Check valve
10. Drain
11. Drain

Electric installation

Electric installations must be performed by a qualified electrician in accordance with applicable regulations.
Installation must be preceded by installation of a residual current device and maintenance switch.
Never start the pump until all wiring and re-checking are performed.
Maintenance switch
RCD
Маx.ström
Fuse
Power cable
NOTE! The above data applies to the electric cable ≤ 10 m. If the cable is longer than 10 meters the cable section must be
prolonged.

Before connecting power supply

Check that installation and pipe connections are like on the diagram.
Check that electrical wires are connected according to the diagram.
Check earth connection carefully.
Check that the pump air inlet and outlet are not blocked.

Wiring diagram

220-240V
1-phase/50Hz
Distribution box
Fuse
Earth fault
L
relay
N
Earth
1
9
Rated current
Leakage current
Connection in the heat pump
L
N
P1
P2
Mainte-
nance
switch
Power cord
Installation Heatpump PHP 2016
5
2
7
9
9
6
10
PVP10
PVP11
11A
12A
30mA
30mA
9A
10A
13A
13A
3x2,5 mm²
3x2,5 mm²
400V
3-phase/50Hz
Distribution box
R
Earth fault
S
relay
T
N
Earth
6
ENGLISH
4
5
9
OUT
9
9
R
IN
11
PVP13
PVP17
13A
16A
30mA
30mA
11A
13.5A
13A
16A
3x2,5 mm²
3x2,5 mm²
Connection in the heat pump
Mainte-
nance
switch
Fuse
3
8
Drawing no: M12399-1
2016-03-02 ASA
PVP28
9A
30mA
7A
10A
5x2,5 mm²
R
S
T N
Power cord