Technical Parameters; Safety; Transporting - Pahlen 14983311 User Manual

Heat pump pvp series inverter
Table of Contents

Advertisement

Heat pump PVP Inverter

Technical parameters

Heat power
in "Smart" operation mode
Heat power
in "Silence" operation mode
C.O.P.
in "Smart" operation mode
C.O.P.
in "Silence" operation mode
Rated power
Rated operation current
Electric connections
Recommended water flow
Pipeline water in and out
Weight
Refrigerant
Refrigerant quantity
Recommended pool volume
A (Ambient conditions А) = Air +26°С, Water +26°С, Humidity 80%.
B (Ambient conditions В) = Air +15°С, Water +26°С, Humidity 70%.
* Data is provided for optimal conditions.
Note!
We reserve the right to change the specifications without prior notice.
Please note that the heat pump funkctions and parameters vary depending on the circumstances. See the rating plate on the
pump for details.

Safety

Make sure that the main power switch is located out of reach of children.
Never remove the protection in front of the fan.
Never put your hands in the air outlet.
Turn off the heat pump during lightning storms in order to prevent damage.
Do not place near the heat pump any objects that can block airflow.
Never use/store flammable gaseous or liquid substances (e.g. paint thinner, paint, fuel ) near the heat pump.
Never attempt to repair the heat pump. In case of an unusual noise, smell, smoke or electric faults - immediately switch off the
machine power and contact your installer.
If the pump has not been used for a long time: switch the power off and drain the heat pump from water. Cover it.

Transporting

Transport the heat pump standing safely in its original packaging.
The heat pump should NOT be lifted with pipe connections since the titanium heat exchanger inside the heat pump can be dam-
aged.
Pahlén is not responsible for any damage caused by improper handling.
PVP10
PVP11
Item no. 14983311
Item no. 14983314
A 2.4–9.8kW*
2.8–11.3kW*
B 1.7–6.5kW*
1.9–7.3kW*
A 2.4–7.8kW*
2.8–9.0kW*
B 1.7–5.1kW*
1.9–5.8kW*
A 6.4–15.0*
6.5–15.1*
B 4.4–7.6*
4.5–7.7*
A 7.4–15.0*
7.5–15.1*
В 5.1–7.6*
5.2–7.7*
0.2–1.4kW
0.22–1.6kW
0.86–6.4A
0.95–7.4A
3–4m³/h
4–6m³/h
49 kg
50 kg
0.85 kg
1.0 kg
20–40m³
25–50m³
PVP13
Item no. 14983315
3.4–13.3kW*
2.3–9.4kW*
3.4–10.4kW*
2.3–7.4kW*
6.4–15.0*
4.4–7.6*
7.4–15.0*
5.1–7.6*
0.25–2.1kW
1.1–9.1A
230V/1-phase/50Hz
5–7m³/h
Ø50mm
52 kg
R410A
1.1 kg
30–60m³
4
ENGLISH
PVP17
PVP28
Item no. 14983316
Item no. 14983318
4.4–17.3kW*
7.0–27.5kW*
2.8–11.4kW*
4.5–18.0kW*
4.4–13.8kW*
7.0–21.7kW*
2.8–8.8kW*
4.5–14.5kW*
6.3–15.2*
6.2–15.2*
4.3–7.8*
4.3–7.8*
7.3–15.2*
7.2–15.2*
5.2–7.8*
5.0–7.8*
0.33–2.6kW
0.58–4.0kW
1.4–10.9A
0.8–5.8A
400V/3-phase 50Hz
6.5–8.5m³/h
10–12m³/h
63 kg
90 kg
1.25 kg
2.6 kg
40–75m³
60–120m³

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents