Self-Diagnosis Function - Panasonic SA-HT330GCT Service Manual

Dvd home theater sound system
Hide thumbs Also See for SA-HT330GCT:
Table of Contents

Advertisement

SA-HT330GCT / SA-HT330GCP

15 Self-Diagnosis Function

15.1. Automatic Displayed Error
Codes
15.1.1. Automatic Display Function
For a power unit error, the code is automatically displayed.
F61:
Automatically displayed on the LCD of
the player.
15.1.2. Re-Display
· For F61 Display
− − − − When the code, F61 is displayed, the power is
automatically turned off.
− − − − The code, F61 is displayed for three seconds, and then
the current time appears.
− − − − To retrieve the code, turn on the power button so that
the code F61 appears, however, is switched to time
display
after three seconds, and the power is
automatically turned off.
15.1.3. Description of Error Code
15.1.3.1. F61
· State, Condition
When the power is turned on, the unit is automatically
turned off. The power does not turn on.
· Cause, Troubleshooting
Power circuit system failure and/or direct current flown to
speaker terminal
Identify the cause and replace with new parts.
Error Code
H15
The disc tray cannot be opened: it closes spontaneously.
H16
The disc tray cannot be closed: it opens spontaneously.
State, Condition
15.2. Memorized Error Codes
15.2.1. Activating Self-Diagnosis Function
and Displaying Method
1. Turn on the power.
2. Select DVD/CD function. With no DVD/CD inserted in the
player, press and hold down the
for at least two seconds, and press the F_SKIP
button for at least two seconds in order to display " T ".
3. Press the
button. If a memorized error is detected, the
result of self diagnosis is displayed.
(Ex.: T H 0 12) (See table below)
If several errors are detected, press the
display each.
15.2.2. Re-Display
· Press the power button to turn off the power, and then turn
on the power.
· The details of self diagnosis are stored in the unit memory.
To retrieve them, follow the procedure described the above,
"Activating
Self-Diagnosis
Method".
15.2.3. Deleting Details of Self Diagnosis
· After repair, press and hold down the
five seconds, "_ CLEAR __" appears for a second and then
" T " appears. (Deleting the details of self diagnosis)
· After repairing errors, be sure to delete the details of self
diagnosis.
Cause, Troubleshooting
Disc tray open/close detection switch (S901/S902) failure.
(Check and replace)
42
button simultaneously
button to
Function
and
Displaying
button for at least

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sa-ht330gcp

Table of Contents