Installing the PT100..........................65 8.7.3. Zero setup of temperature sensors ....................... 66 8.7.4. Absolute thermal output measurements (absolute measurement) with PT100 ........67 Measuring windows of deltawaveC-P ......................69 9.1. The main display „flow1“ ..........................69 9.2. Measuring window "Flow 2“ ........................71 9.3.
Page 3
12.9. Software Reset ............................104 Troubleshooting ............................106 13.1. Integrated sensor test function......................... 107 Troubleshooting ............................109 14.1. Diagnostic menu of deltawaveC-P ......................112 14.1.1. Oscilloscope / Auto-Window........................ 112 14.1.2. Diagnostic menu..........................127 14.2. Software update............................131 Media properties ............................134 Specifications..............................
Page 4
User manual Table of figures Picture 1 Measuring Principle ............................8 Picture 2 deltawaveC-P – With mounted ultrasonic transducers (bottom) and flow transmitters ........10 Picture 3 deltawaveC-P flow transmitter ........................11 Picture 4 signal cables ..............................13 Picture 6 Spacer bar for transducer types XUC-PW-10 und XUC-PW-20..............14 Picture 7 Transducer PW05 (500 kHZ) for large pipes –...
Professional: You already have professional knowledge of ultrasonic measuring systems? ->Set out with the deltawaveC-P Getting Started (separate attachment) ->You may also want to read the chapters that are marked with the green dot,...
Heat measurement is included as standard application. Optional clamp-on PT100 temperature sensors are available. • deltawaveC-P can be operated in cordless mode as well as on a power adapter for operation with 100% duty cycle. • The device supports measurements on piping with diameters from DN10 to DN6000 (depending on the sensor used) •...
Page 7
User manual Test requirements DIN EN 61000-6-1 (10/2007) DIN EN 61000-6-3 (09/2007) systec Controls Mess- und Regeltechnik GmbH 7/139 www.systec-controls.de...
Measurements cover the transit times of the upstream and downstream signals (t1, t2). The electronic circuit of deltawaveC-P measures the transit-time differential of the ultrasonic signals t1 and t2 that that travel upstream and downstream.
Page 9
User manual The flow transmitter uses a sophisticated cross-correlation to detect signals. This ensures a reliable detection of signals even in case of harsh circumstances like gas and/or particle load. systec Controls Mess- und Regeltechnik GmbH 9/139 www.systec-controls.de...
User manual deltawaveC-P and components Picture 2 deltawaveC-P – With mounted ultrasonic transducers (bottom) and flow transmitters Your deltawaveC-P essentially consists of the ultrasonic transducers and the flow transmitter that are mounted onto your piping. systec Controls Mess- und Regeltechnik GmbH 10/139 www.systec-controls.de...
User manual 4.1. deltawaveC-P flow transmitter Picture 3 deltawaveC-P flow transmitter The flow transmitter processes the signals and makes measurement results available to the user. 4.2. Ultrasonic transducers The ultrasonic transducers are mounted onto the piping and transmit and receive the ultrasonic signals that are used in the flow transmitter to calculate the volumetric flow rate.
Page 12
DN32 to DN400. Operating temperatures: -40 °C to 150°C Ultrasonic transducer XUC-PW F5 (0,5 MHz), GREEN housing. For pipe diameters from DN200 to DN6000. Operating temperatures: -40 °C to 80 °C (150 °C optional on request) systec Controls Mess- und Regeltechnik GmbH 12/139 www.systec-controls.de...
(Ultrasonic transducer XUC-PW F5 will be mounted on the pipe without space bar by using the textile band clamps). Space bar “long” is not compatible with ultrasonic transducer model XUC-PW F21 400mm Picture 5a space bar „long“ 40cm systec Controls Mess- und Regeltechnik GmbH 13/139 www.systec-controls.de...
Space bar „short“ is not compatible with ultrasonic transducer models XUC-PW- F20 and XUC-PW-F10 ! Picture 5b space bar „short“ 25cm 4.3.3. Mounting chains for transducer mounting Picture 5 Spacer bar for transducer types XUC-PW-10 und XUC-PW-20 systec Controls Mess- und Regeltechnik GmbH 14/139 www.systec-controls.de...
Picture 6 Transducer PW05 (500 kHZ) for large pipes – Mounting with textile belt 4.3.4. Coupling grease The ultrasonic coupling gel is applied between the ultrasonic transducer and the piping in order to optimize signal input. 4.3.5. PT100 Temperature sensors systec Controls Mess- und Regeltechnik GmbH 15/139 www.systec-controls.de...
4.3.6. 4-20mA analogue output cable The analog output cables can be used, for example, to connect an external data logger or recorder to your deltawaveC-P flow transmitter for the transmission of measured values such as flow rates, or thermal output.
User manual The power adapter is normally used to charge the battery. Your deltawaveC-P, of course, supports permanent operation on mains by using the power adapter. Interfaces of deltawaveC-P 4.4. Reset Down Relais/Impulse T1/T2 Analog Out Power 18,5 VDC...
Page 18
These outputs can be assigned variables such as the flow rate and return a current that is proportional to the value of the variables. The outputs operate in active (power provided by flow transmitter) 2-wire mode. systec Controls Mess- und Regeltechnik GmbH 18/139 www.systec-controls.de...
User manual deltawaveC-P provides a Hardware Reset function that resets the device to a defined initialized state. You trigger a Hardware Reset by actuating the pushbutton switch through the Reset opening on the deltawave, for example, using a paper clip.
Other ultrasonic transducers for smaller or larger pipe dimensions, as well as clamp-on temperature sensors, are available on separate order. You can reach your personal contact partner on the Internet at www.systec-controls.de, or at the phone number +49 (0)89 80 90 60. 4.6. Saftey instructions •...
3 seconds and then release it. switches the backlight On and Off Multifunctional buttons: Use this button to select the function that is displayed next to it on the screen systec Controls Mess- und Regeltechnik GmbH 21/139 www.systec-controls.de...
Confirms your entry Confirms your entries and opens the next window Returns you to the previous window Increases the value Reduces the value Triggers the XYZ function (variable, depending on the application No function systec Controls Mess- und Regeltechnik GmbH 22/139 www.systec-controls.de...
6.1. Basic settings, main menu, navigation 6.1.1. Setting language Switch on the device. During the start sequence, press the multifunctional button that is located next to the "SETUP" field. Confirm the "SETUP LANG." button systec Controls Mess- und Regeltechnik GmbH 23/139 www.systec-controls.de...
Navigation in main menu (flow 1) The "Flow rate 1" measuring window is automatically opened with a delay of a few seconds after power on of the deltawaveC-P and display of the start screen. The "Flow 1" measuring window provides an overview of all data that is necessary for flow and heat measurements.
Page 25
To return to the measuring window, proceed as follows: Select "ESC" -> "MEAS" in the next window You have now learned the fundamentals for operating your deltawaveC-P . You can accelerate access to the main menu after power on by way of a simple trick: select the start sequence "SETUP"...
Select the Time and Date menu command Enter the time in the following notation Hour (hh) : Minute (mm) : Second (ss). Enter the date in the following notation Day (dd) : Month (mm) : Year (YYYY). systec Controls Mess- und Regeltechnik GmbH 26/139 www.systec-controls.de...
Percentage display: Displays the charging state of the battery systec Controls Mess- und Regeltechnik GmbH 27/139 www.systec-controls.de...
Page 28
User manual The times specified apply to a new battery. The factual operating/load cycles may deviate from the specified time values systec Controls Mess- und Regeltechnik GmbH 28/139 www.systec-controls.de...
7.1. Required straight runs The selection of the mounting location has a significant impact on measurement quality. Particularly the charge and discharge area listed in the following table should be taken into account systec Controls Mess- und Regeltechnik GmbH 29/139 www.systec-controls.de...
+/-45% to the horizontal plane. This is based on the fact that there is a risk of the accumulation of bubbles in the upper section and sedimentation in the lower section of the pipe. systec Controls Mess- und Regeltechnik GmbH 31/139 www.systec-controls.de...
User manual Picture 11 Preferable mounting positions for ultrasonic transducers (2) deltawaveC-P uses the cross section of the pipe to calculate the flow. The cross section is calculated from the parameterized inner diameter (user setting). If you have sedimentation in your pipe which decreases the real inner diameter you might get a (usually very small) uncertainty.
In the so-called V-mode, both ultrasonic transducers are mounted onto the same side of the pipe. This mode is the standard for small and medium pipe dimensions. The ultrasonic signals are reflected from the pipe wall. systec Controls Mess- und Regeltechnik GmbH 33/139 www.systec-controls.de...
The Z-mode is a special method for mounting the ultrasonic transducers. In comparison to the V- and W-mode, the signal is transmitted across a shorter distance with this installation method. It is normally used for systec Controls Mess- und Regeltechnik GmbH 34/139 www.systec-controls.de...
Look for a suitable location for mounting the ultrasonic • transducers Parameterize your deltawaveC-P • Mount the ultrasonic transducers onto the piping • Perform a zero calibration • Start the flow measurement • systec Controls Mess- und Regeltechnik GmbH 35/139 www.systec-controls.de...
"QUICK SETUP": The Quick Setup guide offers step-by-step • instructions on the essential tasks you have to complete for deltawaveC-P parameterization. This Quick Setup is quite sufficient for handling most applications and gets you started with fast and efficient parameterization in no time at all.
Page 37
The sonic speed for materials not listed in the tables has to be entered manually. Tables that list additional sonic speed parameters for different materials are available in the annex to these operating instruction systec Controls Mess- und Regeltechnik GmbH 37/139 www.systec-controls.de...
After power on: Select "Setup" -> "Quick Setup" within the start sequence. In the primary measuring window "Flow 1": Select "Setup" -> "Quick "Setup". Start Specify whether to enter the pipe circumference or outer diameter Enter the outer diameter Enter the diameter systec Controls Mess- und Regeltechnik GmbH 38/139 www.systec-controls.de...
Page 39
User manual Enter the pipe's wall thickness: It is advisable to use a wall thickness meter if you do not know this parameter. Choose pipe material: systec Controls Mess- und Regeltechnik GmbH 39/139 www.systec-controls.de...
Page 40
User manual Does the pipe have a lining YES/NO? Enter the thickness | of the lining Select the database, or user input if a material is not listed in the database systec Controls Mess- und Regeltechnik GmbH 40/139 www.systec-controls.de...
Page 41
User manual Choose lining material Enter speed of sound fom data base of user-defined coating Rohrauskleidung Select the medium: systec Controls Mess- und Regeltechnik GmbH 41/139 www.systec-controls.de...
Page 42
User manual Enter the kinematic viscosity of the medium: Enter the thermal capacity of the medium Enter the density of the medium: systec Controls Mess- und Regeltechnik GmbH 42/139 www.systec-controls.de...
Page 43
User manual Select a suitable ultrasonic transducer For information on suitable transducers for specific pipe dimensions, refer to chapter "deltawaveC-P and components “. Select a suitable mounting mode For information on suitable transducers for specific pipe dimensions, refer to chapter "deltawaveC-P and components .
Page 44
XUC-PW-F20 and XUC-PW-F10. The distance between transducers is specified in millimeters and always measured between the faces of transducers 1 and 2. These dimensions are independent of the selected mounting mode. systec Controls Mess- und Regeltechnik GmbH 44/139 www.systec-controls.de...
8.4.1. V-mode and W-mode Mounting distance Picture 15 Mounting of ultrasonic transducers V-mode Picture 16 Example of the V- or W-mode without spacer bar systec Controls Mess- und Regeltechnik GmbH 45/139 www.systec-controls.de...
User manual Picture 17 Example of the V- or W-mode with spacer bar Picture 18 Example of the V-mode mount with fabric-reinforced tensioning tapes for large pipe diameters systec Controls Mess- und Regeltechnik GmbH 46/139 www.systec-controls.de...
(blue arrow) with the help of the knurled screw (A). The ultrasonic transducer type F05 consists only of the sensor sheath and the actual ultrasonic transducer. Sheath Ultrasonic transducer systec Controls Mess- und Regeltechnik GmbH 48/139 www.systec-controls.de...
(“srew transducer into support) Picture 23 Proper application of the acoustic gel on the sensing face of the ultrasonic transducer systec Controls Mess- und Regeltechnik GmbH 49/139 www.systec-controls.de...
(B). Knurled screw (B) 3 4 5 Example: Grid number 5 If the wrong space bar (short or long) is applied, the measurement fails or the measurement will have wrong values. systec Controls Mess- und Regeltechnik GmbH 50/139 www.systec-controls.de...
Attach the chains to the hooks on the transducers while keeping them under (only slightly!) tension. Approach the ultrasonic transducers to the pipe by adjusting the knurled screw (A) until the transducer is pressed slightly onto the pipe. systec Controls Mess- und Regeltechnik GmbH 51/139 www.systec-controls.de...
Using a felt tip pen, draw a line on the pipe along the template • (corresponds with the pipe circumference) Picture 26 Attaching plastic template Draw line Picture 27 Attaching plastic template 2 systec Controls Mess- und Regeltechnik GmbH 52/139 www.systec-controls.de...
(transducer distance). Measure the transducer distance based on the value displayed on your deltawaveC-P , starting from the first line drawn to the position at which the second line is to be drawn (mounting position for face of the second transducer).
Picture 30 Set up the template to mark the mounting position of the second transducer Draw two crosshairs on the same axis, centered on the lines drawn • with the help of the template.. Picture 31 Auxiliary marks systec Controls Mess- und Regeltechnik GmbH 54/139 www.systec-controls.de...
Mount the second transducer. Its face is positioned on the axis of • the second line drawn. The transducer face is centered onto the third crosshair. The transducers are now mounted precisely opposite to each other and are prepared for measuring in Z-mode. systec Controls Mess- und Regeltechnik GmbH 55/139 www.systec-controls.de...
Quick Setup tool. We therefore do not elaborate in closer detail on this topic. Navigate to the main menu: In the primary measuring window "Flow 1": Select "Setup" -> "CMPL. SETUP" systec Controls Mess- und Regeltechnik GmbH 56/139 www.systec-controls.de...
Page 57
User manual Select the parameters to edit, e.g. "Pipe parameters", "Medium parameters", or "Transducer parameters": systec Controls Mess- und Regeltechnik GmbH 57/139 www.systec-controls.de...
Page 58
Does pipe have internal coating? Enter thickness of coating Material of coating Choose from Enter data base customized coating Select: Enter speed of 1 Rubber sound of your 2 … coating E N D systec Controls Mess- und Regeltechnik GmbH 58/139 www.systec-controls.de...
Page 59
2 … Enter kinematic viscosity Enter heat capacity Enter density E N D Direct access to selection of ultrasonic transducer and mounting mode: Transducer Setup Choose transducer Choose mounting mode E N D systec Controls Mess- und Regeltechnik GmbH 59/139 www.systec-controls.de...
- After power on: Select "Setup" within the start sequence - In the primary measuring window "Flow 1": Select "Setup" and “Zero Setup” - Select "Set Zero" The following window opens on completion of zero calibration: systec Controls Mess- und Regeltechnik GmbH 60/139 www.systec-controls.de...
User manual Your deltawaveC-P displays the calculated correction value for the signal transit time on completion of zero calibration: 8.6.2. Zero calibration using the main menu: In the main menu, select "damping/cutOff/Zero" -> "Zero calibration“ Stop flow of media (closing a valve) •...
In the course of zero calibration with closed pipe valves, your deltawaveC-P calculates the transit-time differential that may develop between the transducers and any residual flow. This calculated time (including zero) is automatically included for subsequent calculations during flow measurement.
However, you are well advised to install the transducers in the cooler section, as it is unlikely that they will be operated beyond their permissible temperature limit in these sections. deltawaveC-P displays the thermal output and the accumulated heat quantity systec Controls Mess- und Regeltechnik GmbH 63/139 www.systec-controls.de...
User manual Picture 34 Block diagram of heat measurement deltawaveC-P shows heat (kWh) and thermal output (kW) Calculating thermal output The cross-sectional area of the pipe's inner diameter [A] is multiplied by the flow velocity [v] and specific thermal capacity of the medium [c], as well as the differential temperature of both PT100, [T_hot- T_cold].
The PT100 temperature sensors can be mounted on your piping using a metal strap (photo), mounting chains, or a fabric-reinforced tape strap (which is standard when buying deltawaveC-P package). Install the PT100 on the pipe as follows, for example: Picture 35 Mounted temperature sensor (PT100) The measuring method deployed for the PT100 is a relative measurement.
"Heat quantity" measuring window that is described in the following chapte. Select “READ OFFSET". Now, deltawaveC-P automatically calculates the T2 to T1 offset. On completion of this calculation, the differential temperature T1 to T2 should amount to approximately zero degrees. Use the "Reset Offset"...
Example: The resistance thermometer installed in the pipe displays 80 °C. However, the resistive contact thermocouple PT100 T1 of your deltawaveC-P displays only 78.5 °C. deltawaveC-P also supports manual adjustment of the offset. In this case, specify a setpoint of 80 °C. The setpoint is an absolute value and not an offset.
Page 68
User manual Same procedure is applicable for second temperature sensor. In this case please choose PT100 T2 in calibration menu. systec Controls Mess- und Regeltechnik GmbH 68/139 www.systec-controls.de...
How to open the central measuring window "Flow 1“ After power on: Wait approx. five seconds for the display of the start screen. The deltawaveC-P automatically opens the central measuring window "Flow 1“. Starting in the main menu: Select "ESC" > "MEAS.“...
Change to the diagnostics windows. Only necessary for information or if you do not receive any measurement results Change to measuring window "Flow 2“ providing further information Change to oscilloscope menu where you can watch signals systec Controls Mess- und Regeltechnik GmbH 70/139 www.systec-controls.de...
Table 2 Additional content of menu flow2 Change to the primary measuring window“ "Flow 1". Change to measuring window "Heat“ 9.3. Measuring window "Heat“ How to open the primary measuring window "Heat” systec Controls Mess- und Regeltechnik GmbH 71/139 www.systec-controls.de...
In the primary measuring window "Flow 1": Select "SETUP" -> "CMPL SETUP" -> Navigate to "Units Setup" in the main menu. Select the variable at which you want to change the physical unit: systec Controls Mess- und Regeltechnik GmbH 72/139 www.systec-controls.de...
In the primary measuring window "Flow 1": Select "SETUP" -> "CMPL SETUP" -> Navigate to "Units Setup" in the main menu and then select "Flow" Select the parameter you want to change the unit: systec Controls Mess- und Regeltechnik GmbH 73/139 www.systec-controls.de...
How to access the physical unit submenu "Totalizer" In the primary measuring window "Flow 1": Select "SETUP" -> "CMPL SETUP" -> Navigate to "Units Setup" in the main menu and then select "Total Flow" Select the physical unit: systec Controls Mess- und Regeltechnik GmbH 74/139 www.systec-controls.de...
How to access the physical unit submenu "Heat quantity" In the primary measuring window "Flow 1": Select "SETUP" -> "CMPL SETUP" — In the main menu, select "Units Setup" -> "Heat" Select the physical unit: systec Controls Mess- und Regeltechnik GmbH 75/139 www.systec-controls.de...
(*.txt) which allows easy and quick export into office software like Microsoft Excel or similar. 9.6.2. Time controlled data logging Your deltawaveC-P supports time controlled data logging to the internal SD memory card. systec Controls Mess- und Regeltechnik GmbH 76/139...
Page 77
"NEXT". Assign a file name (min. 4 characters). Use the arrow keys to select the letters, or delete a letter by means of "DEL". Accept the letter with "ENTER". Select "DONE" and press "ENTER" to conclude data input. systec Controls Mess- und Regeltechnik GmbH 77/139 www.systec-controls.de...
Page 78
The data logger does not make average over the cycling period. Always the current values are stored. If you choose interval of 10 seconds the current values each 10 seconds are stored (not the average over last 10 sec). . systec Controls Mess- und Regeltechnik GmbH 78/139 www.systec-controls.de...
Page 79
User manual To delete or to rename existing log files please connect your deltawaveC-P to your PC using the USB cable. Then you can access the log files directly at the SD card. Message „LOG ACTIVE“ is being shown at the display while data logging is going on.
Page 80
User manual The following window appears If you want to cancel data logging please press YES If you cancel data logging the already stored data will be still available on the SD card. systec Controls Mess- und Regeltechnik GmbH 80/139 www.systec-controls.de...
Save/load/edit parameters The primary measuring window "Flow 1": Select "SETUP" -> "CMPL SETUP" -> "Save/load parameters" Your deltawaveC-P provides functions for saving and loading the parameter data. This will save time if you are taking measurements at different locations. To save the parameters, use the arrow keys to select the memory space and confirm your entry with "NEXT“:...
Page 82
The parameter files are stored into an internal data logger an not in the SD card. The SD card is reserved for data log files only. If you perform software reset also stored parameter files will be deleted! systec Controls Mess- und Regeltechnik GmbH 82/139 www.systec-controls.de...
When connected via USB port to a computer (please use USB cable supplied by systec) running one of the operating systems XP, WIN2000, Vista, Windows 7, or MAC OS X.x, your deltawaveC-P is automatically detected as mass storage medium (like a USB stick). Your deltawaveC-P is equipped with a USB 2.0 interface...
The log file will look like this: Each line represents the data from one measuring point. The different values are separated by semicolon. Picture 38 Log file opened by text editor systec Controls Mess- und Regeltechnik GmbH 84/139 www.systec-controls.de...
11.1. Parameterizing the 4 mA to 20 mA current outputs Your deltawaveC-P provides two 4 mA to 20 mA current outputs. These outputs can be assigned different measured values. The outputs are set actively by default. This means that your deltawaveC-P always provides a voltage at these outputs.
Page 87
User manual The outputs of your deltawaveC-P are work in active mode in factory state. That means that the flow transmitter provides the required voltage to run the outputs The inputs of the external device are connected directly to your deltawaveC-P .
Page 88
In the primary measuring window "Flow 1": Select "SETUP" -> "CMPL SETUP". In the main menu, select -> "I/O Setup" -> Analog outputs". Select the analog output to be used: Specify the variable to be output at the analog output: systec Controls Mess- und Regeltechnik GmbH 88/139 www.systec-controls.de...
Page 89
Select the value to be assigned to the 20mA output. The analog outputs at your deltawaveC-P only support unidirectional flow. deltawaveC-P can only provide positive flows to the outputs. The flow display must return positive values. What happens if the value exceeds the parameterized high or low limits?
Page 90
User manual Select the time that expires before deltawaveC-P switches to the fault mode: When do you have an error situation? When do you have an error situation? When do you have an error situation? When do you have an error situation?
User manual 11.2. Parameterize the Relay Your deltawaveC-P is equipped with a relay output. This output can be assigned a function or a range. Example of an external circuitry: Alarm Voltage supply You link an alarm beacon with the output to signal that the flow rate has undershot the lower threshold limit.
Page 92
In addition to parameterized variables such as flow, your deltawaveC-P applies the corresponding unit that is selected in the "Units Setup" setting and appended to the respective variable that is displayed in a measuring...
Page 93
150 m /h. The objective is for deltawaveC-P to shut down the pump as soon as the value drops below a point at which damage to the pump can be expected. So in that case lower limit has to be set to 150m3/h, upper limit to 6000m3/h.
User manual 11.3. Parameterize the Impulse Output deltawaveC-P which have been shipped from January 2013 are equipped with one impulse output. The impulse output is an open collector output. It is possible to allocate different volume values to impulse output (heat/volume).
Page 95
For example if power unit was setup in [kWh] same unit is used automatically as impulse counter unit. systec Controls Mess- und Regeltechnik GmbH 95/139 www.systec-controls.de...
User manual Calibration Your deltawaveC-P provides a calibrating function that can be used to calibrate the flow. It may also be used to calibrate the analog outputs and PT100 temperature sensors. How to access the "Calibration" menu: In the primary measuring window "Flow 1": Select "SETUP" -> "CMPL SETUP"...
User manual Enter an offset percentage that is relative to your calibration reference. To calibrate your deltawaveC-P , it is recommended to take measurements at different flow velocities and then calculate the mean value of the results. systec Controls calculates the mean value based on five different flow velocities.
How to access the "Time and date" menu: In the primary measuring window "Flow 1": Select "SETUP" -> "CMPL SETUP". In the main menu, select "System Setup " -> "Time and date systec Controls Mess- und Regeltechnik GmbH 98/139 www.systec-controls.de...
In the primary measuring window "Flow 1": Select "SETUP" -> "CMPL SETUP" — In the main menu, select "System Setup" -> "Backlight“ Adjust the display brightness by setting value (0% = no backlight, 100% maximum brightness). systec Controls Mess- und Regeltechnik GmbH 99/139 www.systec-controls.de...
"SETUP" field. Confirm the "SETUP LANG." button • Use the arrows in the next window to select the dialog language. • Confirm your entry with "Enter" and exit the menu with "SETUP“. systec Controls Mess- und Regeltechnik GmbH 100/139 www.systec-controls.de...
12.4. Miscellaneous How to access the "Miscellaneous" menu: In the primary measuring window "Flow 1": Select "SETUP" -> "CMPL SETUP" — In the main menu, navigate to "Damping/CutOff/Zero" menu systec Controls Mess- und Regeltechnik GmbH 101/139 www.systec-controls.de...
SETUP". In the main menu, navigate to "System Setup" -> "Damping/Cut off/ Zero" -> "Cut off Flow". Only the flow velocities that are greater than the parameterized "Cut off" will be displayed. Lower velocities will be considered (and displayed) as 0. systec Controls Mess- und Regeltechnik GmbH 102/139 www.systec-controls.de...
SETUP" — In the main menu, navigate to "System Setup" -> "Info Flow Module“. Here you can check e.g. version of your software to check whether update might be available or not. systec Controls Mess- und Regeltechnik GmbH 103/139 www.systec-controls.de...
Hardware reset is only necessary when deltawaveC-P hangs up and can not be operated any longer by using the buttons. Data stored internally or on the SD card will not be deleted.
Page 105
From the main menu (flow1) please choose SETUP -> COMPL SETUP -> SYSTEM -> RESET SYS. After software reset you need to set date&time again! gesetzt (Parametrierung, Datenlogger etc.). Parameter files will be deleted! systec Controls Mess- und Regeltechnik GmbH 105/139 www.systec-controls.de...
Use the following check lists for troubleshooting and check all items listed. If the error that prevents you from taking proper measurements persists after you completed the check, contact your systec delater or the systec Controls Hotline at: +49 (0)89 809 06 0...
At the beginning of the y- line there are two signal packages (3). That packages are the both send signals. Picture 41 Osci window send signal 4. Proceeding with the test procedure there must be a little acoustic coupling grease on one of the two transducers. systec Controls Mess- und Regeltechnik GmbH 107/139 www.systec-controls.de...
(1). The post pulse oscillation (2) depends on the type of ultrasonic transducer and could differ from the example photography below. Post pulse oscillations are not in relation of good working ultrasonic transducers. Picture 43 Osci window send and receive signal systec Controls Mess- und Regeltechnik GmbH 108/139 www.systec-controls.de...
Use a wall thickness meter. You can lease or purchase a wall thickness meter from systec Controls. check the wall thickness entry on the device.
Page 110
You might also try to test your equipment on a different piping section that is close by in order to find out whether or not you can perform a measurement. Check all measuring leads for damage. systec Controls Mess- und Regeltechnik GmbH 110/139 www.systec-controls.de...
Page 111
(flow velocity) and contamination load. Contact us for support if it is necessary to install a siphon for your application. sypho systec Controls Mess- und Regeltechnik GmbH 111/139 www.systec-controls.de...
Oscilloscope / Auto-Window 14.1.1.1. Signal propagation deltawaveC-P offers sophisticated diagnostic menus allowoing experienced users to optimize challenging measurements at harsh conditions. To use the diagnostic menu as a powerful tool for troubleshooting a background in signal propagation is provided by this chapter.
(metals) and small pipes, the pipe wall signal has high amplitude which is similar to amplitude of V-mode signal. When having sound-absorbing materials (plastic, concret) and/or coating the pipe wall systec Controls Mess- und Regeltechnik GmbH 113/139 www.systec-controls.de...
Beside the send signal only the desired signal (Z-signal) is visible. The Z- signal reaches the receiving transducer after T=t1z 14.1.1.2. Oscilloscope menu of deltawaveC-P With the oscilloscope menu you can analyse signals and even manipulate them in order to handle very challenging applications. systec Controls Mess- und Regeltechnik GmbH 114/139 www.systec-controls.de...
Zoom + Zoom + Picture 47 Measuring window Normally deltawaveC-P tries to set the measuring window that way that only the desired signal (e.g. V-mode signal when using V-mode as installation). Other signals (Interfering signals) are out of window. systec Controls Mess- und Regeltechnik GmbH 115/139 www.systec-controls.de...
Using arrow buttons you can move window to left or to right (opens earlier / later). Please note that deltawaveC-P only uses signals within the window. If you move window that way that signal will disappear you might get wrong / no measurement.
The higher the SN the better the signal processing shows good signals with very good SN. Picture 49 Picture 49 Oscilloscope menu showing good signals There is almost no noise at all and a clear and distinguished signal. systec Controls Mess- und Regeltechnik GmbH 117/139 www.systec-controls.de...
20-40% of signal Picture 50 Oscilloscope menu showing noisy signal deltawaveC-P is capable to handle noisy signals thanks to its sophisticated signal processing. But of course a high SN should be approached by user to have some leeway in case of additional interferences.
Page 119
Alignment of transducers: Make sure that transducers are mounted • as suggested by deltawaveC-P. Please also make sure that center of transducers touches the pipe sufficiently (might be problem at very small pipes). You can check the oscilloscope while mounting the transducers.
14.1.1.4. Sharpness of Signals deltawaveC-P uses coded signals to ensure to detect signals also in case of noise. Coded means that deltawaveC-P makes phase shifts within a signal package. Picture 51 shows a sharp signal. You can see ca. 5 waves followed by a phase shift and another waves.
There is basically no phase shift. This Picture 52 might result in misdetection of signals. Thanks to it’s sophisticated signal processing deltawaveC-P is able to handle diffuse signals until a certain limit. Nevertheless sharp signals should be aspired.
Page 122
Alignment of transducers: Make sure that transducers are mounted • as suggested by deltawaveC-P. Please also make sure that center of transducers touches the pipe sufficiently (might be problem at very small pipes). You can check the oscilloscope while mounting the transducers.
Zoom + Picture 53 Interfering signals Here, there are not only the desired signal within the measuring window but also the interfering pipe wall signal and also a part of the W-mode signal. systec Controls Mess- und Regeltechnik GmbH 123/139 www.systec-controls.de...
Page 124
User manual deltawaveC-P uses sophisticated algorithms to separate desired signals from interfering signals. These algorithms are mainly applied when having the auto window function activated. But especially when measuring at very small pipes interference might occur anyway. In that case the user can separate signals (in order to filter out the desired signal) manually in the oscilloscope mode.
20°C speed of sound should be within 1400….1500 m/s). If vs exceeds the expected values you most likely have separated the wrong signal (e.g. pipe wall signal, then vs is showing speed of sound of pipe material) systec Controls Mess- und Regeltechnik GmbH 125/139 www.systec-controls.de...
Page 126
(once you choose YES auto window is activated also when you leave oscilloscope mode. To de-activate auto window you have to enter oscilloscope mode again and answer with systec Controls Mess- und Regeltechnik GmbH 126/139 www.systec-controls.de...
Basically there are three different transducer using different frequencies (500kHz, 1000kHz, 2000kHz) Signal: Shows the type of signal code. deltawaveC-P uses coded signals to allow reliable detection of signals. Signal run time signal 1 (Upstream signal or downstream signal depending on connection of cables).
Measured speed of sound of media. Depends e.g. on temperature. SigQ: Number of valid signals (in percentage). deltawaveC-P makes a lot of measurements per second and automatically filters out unreliable signals. The number of measurements in relation to valid measurements is SigQ.
Quality The quality parameter represents the “thoughness” of the internal filter. Filter means that deltawaveC-P checks each signal if plausible or not using the quality parameter. When choosing quality 0 there will be no filtering. That means that each signal is used for measurement even the bad (and maybe wrong) ones.
Lambda Corr.: Delay can be manually edited (not recommended, only for maintenance) by multiples of wave length of signal. Delay Corr: Shows Lambda Corr in useconds Table 6 Data in diagnostic menu 3 systec Controls Mess- und Regeltechnik GmbH 130/139 www.systec-controls.de...
14.2.1. Check current software version Before making an software update please check version of your software. Switch off deltawaveC-P and restart it. During start you can find version at the bottom of start screen (e.g. 1.0.6c or similar). Please note this value.
Page 132
User manual 14.2.2. Unpack update file Systec provides update files which are usually zipped. The file name represents the version of software. E.g. V1.0.6c Please unpack the file. You will get two files, readme.txt and sysctrol.hex. The file readme contains information of how to update your deltawaveC- P and also information about the new functions / changes to be made by this update.
Page 133
If you should face any problems while copying update files from PC to your deltawaveC-P (hang up) an update might fail since a part of the required file is missing. Please contact your systec dealer in that case.
Need help?
Do you have a question about the deltawaveC-P and is the answer not in the manual?
Questions and answers