TABLE OF CONTENTS Safety Power supply ....................................................Disposal ..........................................................Ventilation system ..................................................Quick guide Control panel ....................................................... Functions ......................................................Alarms ........................................................Fan speed ......................................................Humidity control ..................................................General information Unit type ........................................................... Product description .................................................. Operation and maintenance Maintenance ....................................................Water trap ......................................................
Always disconnect mains electricity to the unit before opening the doors, e.g. for installation, inspection, cleaning and filter change. Disposal Ventilation system Nilan units mainly consist of recyclable materials. They should therefore not be disposed of with household refuse. Take them to your local recycling centre.
3. Setting low humidity: Can be set between 15 and 45% 4. Red diode: Flashes in the event of an alarm Alarms If the unit is in alarm mode, the RED diode on the CTS150 control panel will flash. Alarm description Alarm...
Comfort 200 Top (English) BY NILAN Fan speed Recommended fan speed setting in relation what the installer set. The system may only be switched off, for example, in an emergency where residents are asked to go inside, close doors and windows and shut down the ventilation system.
General information Unit type Product description Comfort 200 Top is a ventilation unit with heat recovery. The unit is designed for air flows up to 308 /h at 100 Pa external duct pressure. The unit draws the humid, vitiated air out of the dwelling via the bathroom, WC, kitchen and utility room and introduces fresh outdoor air into habitable rooms such as living room, bedrooms and office.
Comfort 200 Top (English) BY NILAN Operation and maintenance Maintenance Nilan’s ventilation units last for many years, but to get the best out of them whilst avoiding unnecessary electricity consumption, correct maintenance is important. The following parts require regular maintenance: • Water trap •...
Illustration of filter change 1. The unit must be turned off at the control panel before 2. The suitcase fittings are loosened and the upper door is opening the door removed 3. Remove the two filters from the unit 4. It is a good idea to vacuum the filter chamber to remove any dirt which has collected there 5.
Comfort 200 Top (English) BY NILAN Heat exchanger The heat exchanger should be serviced every two years or so to remove dirt and dust, thereby ensuring unimpeded air flow. A blocked heat exchanger will cause the power consumption to go up.
Comfort 200 Top (English) BY NILAN Ecodesign data Comfort 200 Top SEC* average climate - 38.1 kWh/(m SEC* cold climate - 76.8 kWh/(m SEC* warm climate - 13.3 kWh/(m SEC-Class Type Residential ventilation unit Type of drive Variable speed drive...
Page 12
United Kingdom: S L Services 25 St Leonards Road, Horsham RH13 6EH West Sussex Tlf. +44 (0) 7919 444452 stuart315@aol.com www.nilanuk.com Ireland: Nilan Ireland Ballylahive, Abbeydorney Tlf. +353 (0) 87 9798361 maurice@nilan.ie www.nilanireland.ie Nilan A/S Nilanvej 2 DK-8722 Hedensted Tlf.