Ut-66xxm-i series serial server

Advertisement

Quick Links

Instruction Manual the UT-66XXM-I Series Serial Server
Chapter 1 General data on UT-66XXM-I series serial server ............................................ 2
Product introduction ............................................................................................ 2
Main features ...................................................................................................... 2
c) Application mode .................................................................................................... 4
Instruction on software installation ...................................................................... 5
Description of LED indicators .............................................................................. 5
c) Definition of pins .................................................................................................. 5
a) Technical parameters ............................................................................................. 7
b)Product Configuration Table ................................................................................... 8
a)
Server Menu ....................................................................................................... 8
b)
Serial Port Communication Settings .................................................................... 9
Working mode ................................................................................................... 10
Authority Management ...................................................................................... 16
System Stats ..................................................................................................... 16
Miscellaneous ................................................................................................... 16
Chapter 5 Troubleshooting of UT-66XXM-I series serial server ....................................... 16
Unable to open a serial port .............................................................................. 17
Can't receive/send data .................................................................................... 17
Forget the password previously set ................................................................... 17
Lousy code received/sent ................................................................................. 17
f) The serial communication server is used as the dialing server and the connection is established
normally. But it can't be open by a PC using IE, while inputting the IP in the address bar will do
17
g) The serial communication server is used as a dialing server and the connection is established
normally. But it can't be open fully or at all when using IE for complicated pages or downloading
of large files ........................................................................................................ 17
Unsuccessful PPP connection .......................................................................... 17
Can't be connected as a TCP server ................................................................ 18
Chapter 6 Accessories .................................................................................................... 18
Modification of IP address ................................................................................. 18
Creation of virtual serial port ............................................................................. 18
UTEK TECHNOLOGY (ASIA) CO., Ltd.

Table of Contents

http://www.szutek.com
Page 1/21
0755-27886063

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UT-6602M-I and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for UTEK UT-6602M-I

  • Page 1: Table Of Contents

    ......................17 Unsuccessful PPP connection ................17 Can’t be connected as a TCP server ..............18 Chapter 6 Accessories ....................18 Modification of IP address ................. 18 Creation of virtual serial port ................18 UTEK TECHNOLOGY (ASIA) CO., Ltd. http://www.szutek.com 0755-27886063...
  • Page 2: Chapter 1 General Data On Ut-66Xxm-I Series Serial Server

    IP, TCP, HTTP, ICMP, SOCKET, UDP; Full English interface for all programs, wizards are easy to use even for new computer users. UT-66XXM-I series serial server includes the following models UT-6602M-I dual port serial UT-6604M-I quad port serial server server...
  • Page 3 The UT-66XXM-I series serial server adopts the following security schemes to ensure the safe use of the product by the user. ☆ Allows setting a server administrator password, where only the system administrator is allowed to manage the terminal UTEK TECHNOLOGY (ASIA) CO., Ltd. http://www.szutek.com 0755-27886063...
  • Page 4: C) Application Mode

    The ex-factory IP address of the UT-66XXM-I series serial server is 192.168.1.125, and the subnet mask is 255.255.255.0 c) Application mode 1. Virtual serial mode 2. Point-to-point mode 3. Point-to-multipoint mode 4. Multi-host mode (up to 6 hosts) UTEK TECHNOLOGY (ASIA) CO., Ltd. http://www.szutek.com 0755-27886063...
  • Page 5: Chapter 2 Instruction On Installation Of Ut-66Xxm-I Series Serial Server

    Power connection UT-6608M-I 10/100M Network Power connection UT-6616M-I Power Network 10/100M Network full/half duplex indicator connection c) Definition of pins Definition of serial pins for UT-6602M-I RJ45 RS-232 RS-485 RS-485 RS-422 HALF FULL RJ45 DATA+ TxD+ TxD+ DATA- TxD- TxD-...
  • Page 6 RxD+ RxD- RxD- 3. Definition of the UT-6616M-I serial pins RJ45 RS-232 RS-485 RS-485 FULL RS-422 HALF RxD+ 1 RxD+ 1 TxD+ 2 TxD+ 2 RxD- 3 RxD- 3 TxD- 4 TxD- 4 UTEK TECHNOLOGY (ASIA) CO., Ltd. http://www.szutek.com 0755-27886063...
  • Page 7: Chapter 3 Echnical Parameters Of Ut-66Xxm-I Series Serial Server

    Windows NT/2000/XP Operating -10℃————60℃ Temperature Working 5%————95% humidity Storage -20℃————85℃ temperature Storage 5%————95% humidity Certification FCC、CE DC 5V、2A Power supply AC 220V Material Metal housing Dimensio 113×77×0.91in 160×90×1.18in Standard 19 inch, 1U of height UTEK TECHNOLOGY (ASIA) CO., Ltd. http://www.szutek.com 0755-27886063...
  • Page 8: B)Product Configuration Table

    Console time out (access the serial server via the console port) Boot Host Extension option (starting the host) Boot File Extension option (import files) Submit Submit (the above options of the serial ports must be submitted to complete the settings) UTEK TECHNOLOGY (ASIA) CO., Ltd. http://www.szutek.com 0755-27886063...
  • Page 9: Serial Port Communication Settings

    “Reset ports”, select “port1” and click on the “Submit” button to submit) Apply to all ports Apply to all ports (this option can be checked if all ports are of the same settings) UTEK TECHNOLOGY (ASIA) CO., Ltd. http://www.szutek.com 0755-27886063...
  • Page 10: C) Working Mode

    Submit (the above options of the serial ports must be submitted to complete the settings) Apply to all ports Apply to all ports (this option can be checked if all ports are of the same settings) UTEK TECHNOLOGY (ASIA) CO., Ltd. http://www.szutek.com 0755-27886063...
  • Page 11 [dcdon] means that the server starts a connection when DCD of the corresponding serial RS-232 port is set to a high value; [dsron] means that the server starts a connection when DSR of the corresponding serial RS-232 port is set to a high value; UTEK TECHNOLOGY (ASIA) CO., Ltd. http://www.szutek.com 0755-27886063...
  • Page 12 UNIX host.) MODEM Mode MODEM configuration (This option has three parameters: [none], [in] and [out]. [none]: MODEM control is invalid; [in]: MODEM is waiting for dial in; [out]: MODEM dials out UTEK TECHNOLOGY (ASIA) CO., Ltd. http://www.szutek.com 0755-27886063...
  • Page 13 The local mask. Request DNS Request for the DNS server (Whether or not request the IP address of the domain server during the connection to the server end, Yes for request, No for not request.) UTEK TECHNOLOGY (ASIA) CO., Ltd. http://www.szutek.com 0755-27886063...
  • Page 14 Allocation of DNS server (Whether or not allocate the IP address of the domain server to the client end during the connection with the client end. Yes for request, No for not request.) UTEK TECHNOLOGY (ASIA) CO., Ltd. http://www.szutek.com 0755-27886063...
  • Page 15 “ENTER” received from a serial port to a “NEW LINE” and then send it to the Ethernet; [cr-lf] means that the server will change an “ENTER” received from a serial port to an “ENTER” and a “NEW LINE” and then send them to the Ethernet. UTEK TECHNOLOGY (ASIA) CO., Ltd. http://www.szutek.com 0755-27886063...
  • Page 16: D) Authority Management

    Observe the power indicator, the LAN indicator and the ACT (this lamp is off when the 10M network is connected; and it is only on when the 100M network is connected.) UTEK TECHNOLOGY (ASIA) CO., Ltd. http://www.szutek.com...
  • Page 17: B) Unable To Open A Serial Port

    ‘1’ (i.e. if the serial DCD signal of the serial communication server is ‘high’). If not, the serial communication server will not start PPP 2. Make sure the authentication modes of the client end and the server end are consistent, and the user name and the password established are matched. UTEK TECHNOLOGY (ASIA) CO., Ltd. http://www.szutek.com 0755-27886063...
  • Page 18: I) Can't Be Connected As A Tcp Server

    IP of the switch is 192.168.1.1, and then the IP address of the server should be 192.168.1.XXX. Creation of virtual serial port 1. Run the virtual serial port setup file “setup.exe”, the “Setup” window will pop up, click “Yes” to go to the next step. UTEK TECHNOLOGY (ASIA) CO., Ltd. http://www.szutek.com 0755-27886063...
  • Page 19 3. In this window you will be noted about where the virtual serial port software is installed. Click “Next” to go to the next step 4. The prompt indicates that the installation is to be started. Click “Install” to go to the next step UTEK TECHNOLOGY (ASIA) CO., Ltd. http://www.szutek.com 0755-27886063...
  • Page 20 “immediately” for an instant connection. Then click “OK”. Configure other COM ports in the same way.( It’s very important to press the “Save” button after finishing the required COM ports before you can use the virtual COM ports.) UTEK TECHNOLOGY (ASIA) CO., Ltd. http://www.szutek.com 0755-27886063...
  • Page 21 Page 21/21 UTEK TECHNOLOGY (ASIA) CO., Ltd. http://www.szutek.com 0755-27886063...

This manual is also suitable for:

Ut-6604m-iUt-6608m-iUt-6616m-i

Table of Contents