Compact Speed Log System
Operation and Installation Manual
SKIPPER Electronics AS
Enebakkveien 150
P. O. Box 151, Manglerud
0612 Oslo, Norway
www.skipper.no
EML224 / DL1
Telephone: +47 23 30 22 70
Telefax:
+47 23 30 22 71
E-mail:
support@skipper.no
Co. reg. no: NO-965378847-MVA
Document no: DM-M001-SA
Rev:0702
For software ver 1.20
Date: 2017-01-12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EML224 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Skipper EML224

  • Page 1 EML224 / DL1 Compact Speed Log System Operation and Installation Manual SKIPPER Electronics AS Telephone: +47 23 30 22 70 Enebakkveien 150 Telefax: +47 23 30 22 71 Document no: DM-M001-SA P. O. Box 151, Manglerud E-mail: support@skipper.no Rev:0702 0612 Oslo, Norway Co.
  • Page 2 Electronics AS OpInMan EML224/DL1 Compact Speed Log System 1 AXIS DOPPLER SPEED LOG COMPACT VERSION EML 224 1 OR 2 AXIS ELECTROMAGNETIC SPEED LOG COMPACT VERSION OPERATION AND INSTALLATION MANUAL Copying of this document, and giving it Weitergabe sowie vervielfältigung dieser...
  • Page 3 OpInMan EML224/DL1 Compact Speed Log System Electronics AS Electronics AS ____________________________________________________________________________ COMMUNICATING WITH US If you need more information, support or other assistance from us, do not hesitate to contact us: SKIPPER Electronics AS P. O. Box 151, Manglerud 0612 Oslo...
  • Page 4: Overview

    Electronics AS OpInMan EML224/DL1 Compact Speed Log System OVERVIEW ontent of the manual ___________________________________________________________________________ erminology Terms, units and abbreviations used in this manual. ntroduCtion This part introduces you to the Compact speed log family. 1 – p hapter hysiCal installation Correct installation of the system will ensure problem free service for many years.
  • Page 5 The Compact display is alphanumeric and as such, is restricted in the amount of information it can display. SKIPPER Electronics AS is continuously developing support tools to ease use of its products. The Compact system allows for the user to extract additional information about the systems condition.
  • Page 6: Table Of Contents

    Electronics AS OpInMan EML224/DL1 Compact Speed Log System TABLE OF CONTENTS Overview Content of the manual Terminology Terms used in this manual Units Abbreviations Introduction The Compact speed log family Interconnection diagram Chapter 1 Physical installation Mounting the hull metalwork...
  • Page 7 OpInMan EML224/DL1 Compact Speed Log System Electronics AS Demo mode Setup of alarms Menu diagram Chapter 3 Calibration The principles Speed calibration modes Checking the speed calibration Water temperature offset Chapter 4 Runtime operation Runtime screens Alarms Adjusting the alarms...
  • Page 8 Electronics AS OpInMan EML224/DL1 Compact Speed Log System 6) Compact display connection diagram Appendix 3 Output formats Pulse outputs NMEA outputs NMEA inputs NMEA alarm Appendix 4 Sending the system for repair Appendix 5 Other options with the Compact display...
  • Page 9: Terminology

    OpInMan EML224/DL1 Compact Speed Log System Electronics AS TERMINOLOGY erms used in this manual ____________________________________________________________________________ UNITS Unless otherwise stated, all values shown on the display are as follows: Distance Nautical miles (nm) Speed Nautical miles per hour (kn) Pulse indication...
  • Page 10 Electronics AS OpInMan EML224/DL1 Compact Speed Log System Outgoing NMEA messages follows: VMVLW / VDVLW $VMVLW,.…,Trip and total VMMTW / VDMTW $VMMTW,…,Water temperature VMVHW / VDVHW $VMVHW,…,Relative speed through water VMVBW / VDVBW $VMVBW,..,Multiple speed VMXDR / VDXDR $VMXDR,..,Speed direction VMALR / VDALR $VMALR,..,Cause...
  • Page 11: Introduction

    ___________________________________________________________________________ The SKIPPER Compact speed log family is a set of speed logs designed to have a minimal footprint on the bridge consoles, but still keeping full functionality. This manual covers two systems, built up of the same electronic units and wiring methodology, with one of two sensor technologies.
  • Page 12: Interconnection Diagram

    Electronics AS OpInMan EML224/DL1 Compact Speed Log System INTERCONNECTION DIAGRAM Page 12 of 68 Date: 2017-01-12...
  • Page 13: Physical Installation

    OpInMan EML224/DL1 Compact Speed Log System Electronics AS CHAPTER 1 hysiCal installation ___________________________________________________________________________ Installation usually takes place in two/three phases: 1. Mounting of the hull metalwork 2. Cabling and mounting of the electronics and sensor 3. Initialisation and calibration of the system...
  • Page 14: Mounting The Sensor

    In this case, special length hull fitting and sensor may be ordered from SKIPPER. Before hull fitting installation procedure is initiated, always check that the hull fitting valve can be properly operated and that the sensor can be removed in the selected location.
  • Page 15: Part Positioning And Welding

    The sensor is supplied with 40 m of cable. This should be guided to a dry area where a junction box (yard supply or SKIPPER part JB12) should be used to extend the cable to the bridge. The sensor is a smart sensor and outputs propriety NMEA messages.
  • Page 16: Power

    Electronics AS OpInMan EML224/DL1 Compact Speed Log System Up to 40 m Use supplied cable Up to 100 m 4 twisted pairs min 0.5 mm Up to 300 m 4 twisted screen pairs 1.5 mm Up to 600 m 4 twisted screen pairs 2.5 mm...
  • Page 17: The Pulse Output

    OpInMan EML224/DL1 Compact Speed Log System Electronics AS THE PULSE OUTPUT A single pulse output is available. This pulses at a rate proportional to the longitudinal speed. (This is the required output for RADAR systems). The pulse is active high and the pulse length is 60 ms. This output is located on pin 9 and 10 on connector J301 and is attached to an optocoupler.
  • Page 18: Jb60Cd Interconnection Diagram

    Electronics AS OpInMan EML224/DL1 Compact Speed Log System JB60CD INTERCONNECTION DIAGRAM Large version in Appendix 2, on “3) JB60CD Cabling diagram” on page 50 Page 18 of 68 Date: 2017-01-12...
  • Page 19 OpInMan EML224/DL1 Compact Speed Log System Electronics AS Page 19 of 68 Date: 2017-01-12...
  • Page 20: Jb60Cd Connection Methods

    Electronics AS OpInMan EML224/DL1 Compact Speed Log System JB60CD CONNECTION METHODS Page 20 of 68 Date: 2017-01-12...
  • Page 21: Jb60Cd-Sa Connection Methods

    OpInMan EML224/DL1 Compact Speed Log System Electronics AS JB60CD-SA CONNECTION METHODS Page 21 of 68 Date: 2017-01-12...
  • Page 22: Speed Direction (Cd401Eb/Cd401Db Only)

    Electronics AS OpInMan EML224/DL1 Compact Speed Log System SPEED DIRECTION (CD401EB/CD401DB ONLY) CD401EB and CD401DB are speed log displays developed for vessels going in both directions, like ferry boats. On these systems the NMEA signal out to repeaters are reversable. The wanted speed direction can be switched by connecting the DIMUP-input to Vcc and connect a switch between the DIMCOM-input and ground.
  • Page 23: Setting Up The Compact Display

    OpInMan EML224/DL1 Compact Speed Log System Electronics AS CHAPTER 2 etting up the ompaCt display ____________________________________________________________________________ PRINCIPLES The CD401XX Compact display is a flexible dot matrix LED display designed to display navigation data. The display can be user programmed to show most kinds of numerical data, from NMEA messages or self generated.
  • Page 24: Configuring Of Data Screens

    Electronics AS OpInMan EML224/DL1 Compact Speed Log System screens available. The screen menu allows the user to configure and choose which runtime screens to be included in normal operation. UP (↑) and DOWN (↓) buttons will scroll to the available screens. By using the SET button, the user can control each individual screen to ON or OFF.
  • Page 25: Setup Of Inputs And Outputs

    OpInMan EML224/DL1 Compact Speed Log System Electronics AS Example: Configuration screen Runtime screen Configuration screen Runtime screen SETUP OF INPUTS AND OUTPUTS The system will allow many NMEA formats to be displayed: VMVBW Speed long, trans, forward water speed VMMTW...
  • Page 26: Changing The Baud Rate

    Electronics AS OpInMan EML224/DL1 Compact Speed Log System CHANGING THE BAUD RATE The NMEA 0183 (IEC61162-1) standard is 4800 baud. Some vessels run with higher baud rates. 4800, 9600, 19200, 38400, 57600 and 115200 baud rates can be selected in the baud page of the setup menu. This page contains two sub menus, one for the sensor and one for the NMEA port.
  • Page 27: Demo Mode

    OpInMan EML224/DL1 Compact Speed Log System Electronics AS DEMO MODE A demo mode is available, and can be activated in the diagnostics menu. Three/ four modes are available: Mode 1; is a dynamic demo mode taking the present value as the start point and slowly varying all the available values.
  • Page 28: Menu Diagram

    Electronics AS OpInMan EML224/DL1 Compact Speed Log System Menus MENU DIAGRAM Scrollable menu system. Accessed with SET and MENU pressed simultaneously ▲ Next sub menu ▼ Prev sub menu SET Select sub menu MENU Return System setup (SETUP) Calibration (CALIB)
  • Page 29 OpInMan EML224/DL1 Compact Speed Log System Electronics AS Screen configuration Diagnostics advanced Screens (SCRN) setup (DIAG) (CONFG) Activate/deactivate user Diagnose and adjust less Change the messages being definable and runtime displayed on each user screen used parameters screens ▲ Next sub menu ▲...
  • Page 30: Calibration

    1st leg Callibration procedure If necessary, the procedure should be repeated at different speeds. SKIPPER recommend that calibration is performed at a low speed and a high speed. If the user is not able to turn the vessel and is sure there is no current, the calibration procedure can be stopped after the first leg and saved as a calibration point.
  • Page 31: Speed Calibration Modes

    OpInMan EML224/DL1 Compact Speed Log System Electronics AS Figure 3.2 Shows plotting a calibration path on the chart. The leg should take at least 5 minutes to sail (distance can be shorter when sailing slowly). Reducing heading errors. New generation sea valves can be manually adjusted to ensure the sensor is correctly aligned.
  • Page 32 Electronics AS OpInMan EML224/DL1 Compact Speed Log System SPEED CALIBRATION MODES The EML224/DL1 Compact has two modes of speed calibration: 1. Manual 2. Semi-automatic Manual mode The calibration – (MANUL) menu will allow the user to *Note adjust the heading offset (*see note below), and the speed calibrations individually.
  • Page 33: Checking The Speed Calibration

    OpInMan EML224/DL1 Compact Speed Log System Electronics AS • The line should be sailed at constant stable speed and the line should represent at least 5 minutes of sailing at the current speed. • Leg length setting. (Adjust the length to match the line drawn on the chart).
  • Page 34: Water Temperature Offset

    Electronics AS OpInMan EML224/DL1 Compact Speed Log System CHECKING THE SPEED CALIBRATION To check that the calibration points are not too far from the ideal linearity, the Calibration – GRAPH menu will plot the calibration points on the screen. The user may use up (↑) and down (↓) to select a calibration point and then adjust...
  • Page 35: Runtime Operation

    36). Some of the menu screens (i.e alarms) are also available in the run mode. The EML224 Compact can be dimmed in any of the run screens using the up (↑) and down (↓) buttons. If trip/total are selected as a displayed parameter, they can be toggled using the SET button.
  • Page 36: Runtime Diagram

    Electronics AS OpInMan EML224/DL1 Compact Speed Log System RUNTIME DIAGRAM X = possible to switch off display Page 36 of 68 Date: 2017-01-12...
  • Page 37: Checking Out Your System

    This is available in the diagnostics menu. In addition, an up to date diagnostics guide can be downloaded from the support pages of www.skipper.no. Also, a SKIPPER service software is available for download providing diagnostic support.
  • Page 38 Electronics AS OpInMan EML224/DL1 Compact Speed Log System Test No. What it does What is wrong? Write out 80 characters Manually check the output. If fail, try to NMEA, ask user to to restart. press if ok, or read back.
  • Page 39: Test Points Within The System

    OpInMan EML224/DL1 Compact Speed Log System Electronics AS TEST POINTS WITHIN THE SYSTEM In addition to the internal system testing, it is also possible to connect a PC with a COM port to the 9 pin RS-232 ”COMPACT” DSUB in the JB60CD electronic unit.
  • Page 40 Electronics AS OpInMan EML224/DL1 Compact Speed Log System JB60CD-XX Larger version in Appendix 2, “3) JB60CD Cabling diagram” on page 50 Page 40 of 68 Date: 2017-01-12...
  • Page 41: Maintenance

    OpInMan EML224/DL1 Compact Speed Log System Electronics AS CHAPTER 6 aintenanCe ___________________________________________________________________________ ROUTINE MAINTENANCE EML If the EML 224 sensor begins to underestimate the vessels speed, there may be growth forming on the pins. These pins are made of a resistant, anti-rust metal.
  • Page 42: Master Reset (Factory Default Settings)

    Electronics AS OpInMan EML224/DL1 Compact Speed Log System SKIPPER website (www.skipper.no) and may be downloaded and the system upgraded using a PC connected to the ’Compact’ COM port in the electronic unit (JB60CD). Alternatively a chip can be supplied (with an additional cost) with the new software.
  • Page 43: Appendix 1

    ____________________________________________________________________________ EML224. The EML224 Compact system works using Kirchoffs right hand rule (based upon Faradays law of generators) which states that a conductor (sea water) moving through a magnetic field (generated in sensor) will produce a current orthogonal to both field and movement. So movement of the vessel through sea water with at least 5 ppt salinity will produce a current across the pins orthogonal to the ships motion.
  • Page 44 Electronics AS OpInMan EML224/DL1 Compact Speed Log System Doppler DL1. The Doppler system operates by sending a known frequency sound into the water, and listening to the reflected echo from the minute particles in the water. If the particles are moving towards the sensor, the frequency goes up, if away, the frequency goes down.
  • Page 45: Appendix 2

    OpInMan EML224/DL1 Compact Speed Log System Electronics AS APPENDIX 2 eChaniCal drawings ___________________________________________________________________________ To help planning and installation, the following diagrams are supplied. 1. System overview diagram 2. System specifications 3. JB60CD Cabling diagram 4. JB60CD Mounting diagram 5. Compact display mounting diagram 6.
  • Page 46: System Overview Diagram

    Electronics AS OpInMan EML224/DL1 Compact Speed Log System 1) SYSTEM OVERVIEW DIAGRAM Page 46 of 68 Date: 2017-01-12...
  • Page 47: System Specifications

    OpInMan EML224/DL1 Compact Speed Log System Electronics AS 2) SYSTEM SPECIFICATIONS SY-DL1 EML124C EML224C Single axis Single axis Dual axis Number of axis Speed range long (knots) ±40 ±40 ±50 Speed range trans (knots) ±40 Water track (from) (meters) 0.25 m Accuracy (better than) 0.2 or 2 %...
  • Page 48 *The Compact EML124/DL1, has only longitudinal output and will therefore only give that information within the NMEA outputs. **The Compact EML224 Backwards uses a XDR sentence with an angular displacement of either 0 or 180 degrees for transducer no. 1 to indicate the direction.
  • Page 49 OpInMan EML224/DL1 Compact Speed Log System Electronics AS This page intentionally left blank Page 49 of 68 Date: 2017-01-12...
  • Page 50: Jb60Cd Cabling Diagram

    Electronics AS OpInMan EML224/DL1 Compact Speed Log System 3) JB60CD CABLING DIAGRAM COMPACT LD301 GREEN NMEA (JB60CD) SW300 LD300 NMEA 110-240VAC NMEA IN A NMEA IN B NMEA 1 NMEA 2 NMEA 2 To the bridge PULS 1A PULS 1B...
  • Page 51 OpInMan EML224/DL1 Compact Speed Log System Electronics AS RevNo Revision note Date Signature Checked Compact RS 232 J201 DIAGNOSTICS COMPACT Head RS 232 J202 DIAGNOSTICS SENSOR J300 RED/BLACK WHITE/RED YELLOW/RED GREEN/RED RED/BLUE JP400 GREY TURQOISE PINK JUMPER ORANGE VIOLET BROWN...
  • Page 52: Jb60Cd Mounting Diagram

    Electronics AS OpInMan EML224/DL1 Compact Speed Log System 4) JB60CD MOUNTING DIAGRAM Page 52 of 68 Date: 2017-01-12...
  • Page 53: Compact Display Mounting Diagram

    OpInMan EML224/DL1 Compact Speed Log System Electronics AS 5) COMPACT DISPLAY MOUNTING DIAGRAM SKIPPER Menu COMPACT DISPLAY ..Menu Power consuption: 24 VDC/ 3W Protection code: IP56 Page 53 of 68 Date: 2017-01-12...
  • Page 54: Compact Display Connection Diagram

    Electronics AS OpInMan EML224/DL1 Compact Speed Log System 6) COMPACT DISPLAY CONNECTION DIAGRAM Page 54 of 68 Date: 2017-01-12...
  • Page 55 OpInMan EML224/DL1 Compact Speed Log System Electronics AS Page 55 of 68 Date: 2017-01-12...
  • Page 56: Appendix 3

    Electronics AS OpInMan EML224/DL1 Compact Speed Log System APPENDIX 3 utput formats ___________________________________________________________________________ PULSE OUTPUTS There is one output channel with possibility for two galvanically separated output drivers. It is possible to set number of pulses per nautical mile (p/nm) for the optocoupled outputs.
  • Page 57: Nmea Inputs

    In the unlikely chance that a system fails, it may be necessary to send a part of the system back for repair. Make contact with your local dealer or SKIPPER for Returns Materials Authorisation number (RMA). (A list of service centres is available on www.skipper.no).
  • Page 58: Appendix 5

    Compact and these can be activated using the CODE page in the setup menu. On this page, the systems unique ID is displayed. The new options can be purchased from the SKIPPER retailer to add extra functions. You will receive Page 58 of 68...
  • Page 59: Interfacing With Your Display

    This can be performed by connecting to the electronic unit (JB60CD) ‘compact’ port, or directly through the NMEA port. In this way, error messages can be retrieved when required. The SKIPPER Service software are available if required. The following messages exists: •...
  • Page 60: Error Messages

    Electronics AS OpInMan EML224/DL1 Compact Speed Log System ERROR MESSAGES Symptom: Screen shows error instead of data. Reason: If no data is received from the sensor, the screen will show ‘ERROR’. Fix: Check the LEDs are flashing in the Electronic unit. LD 100, LD 200.
  • Page 61 OpInMan EML224/DL1 Compact Speed Log System Electronics AS Error Failure What it means What to do codes message Can not open The internal Restart communications are not giving the expected response Can not open Com port is having Restart com 0 (NMEA)
  • Page 62 Electronics AS OpInMan EML224/DL1 Compact Speed Log System Error Failure What it means What to do codes message Security save Could not save failed the new security settings Error table Can not save the error Check soldering confirmation log. on components failed –...
  • Page 63 OpInMan EML224/DL1 Compact Speed Log System Electronics AS Error Failure What it means What to do codes message Reply failure – The EML is not Check the no contact with responding connection is correct. Restart, check the options are correct...
  • Page 64: Appendix 6

    ____________________________________________________________________________ THE SKIPPER SERVICE SOFTWARE SKIPPER has developed support software allowing the user to use a single package to maintain the system. The software can be downloaded from the SKIPPER website www.skipper.no. When opening the software, the user should select the correct hardware, and then follow the instructions.
  • Page 65: Installation/Commisioning Of The Compact Speed Log

    OpInMan EML224/DL1 Compact Speed Log System Electronics AS INSTALLATION/COMMISIONING OF THE COMPACT SPEED LOG Boat/Build Name Date: Bridge Manufacturer: Equipment Summary: Display: CD401 - MB D1 S e r i a l Electronic JB60 - Serial No.: Unit Cable Length:...
  • Page 66 Electronics AS OpInMan EML224/DL1 Compact Speed Log System This page intentionally left blank Page 66 of 68 Date: 2017-01-12...
  • Page 67 OpInMan EML224/DL1 Compact Speed Log System Electronics AS This page intentionally left blank Page 67 of 68 Date: 2017-01-12...
  • Page 68 SKIPPER Electronics AS Telephone: +47 23 30 22 70 Enebakkveien 150 Telefax: +47 23 30 22 71 P. O. Box 151, Manglerud E-mail: support@skipper.no 0612 Oslo, Norway Co. reg. no: NO-965378847-MVA www.skipper.no...