USING YOUR ICE MAKER
1. Open the cover, remove the ice basket and pour water into tank.
Keep water level below the water level mark.
2. Press "Power" button on the control panel to begin the ice making cycle.
3. Select the ice cube size by pressing the "Select" button. If the room temperature is lower
than 60℉, it is recommended to select small ice cube in order to avoid ice sticking together.
4. The ice making cycle lasts approx. 6 to 13 minutes, depending on selection of ice cube size
and the room temperature. The recommended room temperature is 50℉ to 105 ℉.
5. If water pump can't inject water, the ice maker will stop automatically, and the "Add Water"
indicator will be on. Press "Power" button, fill water up to the max. water level mark and
press "Power" button again to turn on the unit again. Allow the refrigerant liquid inside the
compressor at least 3 minutes to settle before restarting.
6. The ice maker stops when the ice basket is full and the "Ice" indicator will be on. Warning:
Direct sunlight or sunlight reflection may cause infared sensor malfunction. If the
unit doesn't stop even if ice cubes obstruct sensor, move the unit where no sunlight.
7. Change water in the water reservoir every 24 hours to ensure a reasonable hygiene level.
If unit isn't to be used, drain all the water and dry the tank.
TROUBLESHOOTING
PROBLEM
"Add Water" indicator is
on.
"Ice" indicator is on.
Ice cubes stick together.
Ice making cycle is normal
but no ice formed.
POSSIBLE CAUSE
Lack of Water.
Ice is full in basket.
The ice making cycle is
too long.
Water
temperature
inner tank is too low.
Room
temperature
water
temperature
inner tank is too high.
Refrigerant
in
cooling
system leaks.
Pipe
in
the
cooling
system is blocked.
7
SOLUTION
Stop the ice maker, fill water, and
press "Power" button again to
restart the unit.
Remove
ice
from
Continuous press "Select" button
5 seconds, the unit could make
ice 10 cycles even "Ice" indicator
is on.
Stop the ice maker, and restart it
when the ice blocks melt. Select the
small size ice cube selection.
in
Replace the water. Temperature of
water recommended at 45℉-90℉
or
The room temperature should be 50
℉-105℉, water temperature should
in
be 45℉-90℉
Verify by a qualified technician.
Verify by a qualified technician.
ice