• See chapter 6 for further information. neutral position when released. • Check the carrying handle. It must be firmly fixed. • See chapter 6 for further information. • Check the protection covers. They must be present and undamaged. • See chapter 6 for further information. RESQTEC Manual SPREADER X-series (DM064K08)
• Female dust cap releases when female coupler is released (rotate and pull back). • Male dust cap releases by simply pulling it. Align the NEO1 female coupler located on the hose with the NEO1 male coupler located on the product. Push to connect in one swift motion (if difficult to connect refer to chapter 4.10 for pressure release). RESQTEC Manual SPREADER X-series (DM064K08)
USER MANUAL SPREADER X-SERIES 4.7. DISCONNECTING THE RESQTEC NEO1 COUPLER Rotate the NEO1 female coupler unlock ring in the direction of the arrow and pull backwards. Make sure the control handle is not engaged when disconnecting (neutral position). The NEO1 female coupler on the hose ejects automatically.
USER MANUAL SPREADER X-SERIES 4.8. CONNECTING THE RESQTEC STD COUPLER Check whether the pump relief valve is in its neutral/release pressure relief position (with exception of NEO1). NEVER TRY TO CONNECT THE COUPLERS IF THE PUMP IS SWITCHED TO OPERATION.
Push the pressure release activator pin, located on the backside of the NEO1 male dust cap, onto the NEO1 male coupler which contains the pressure release valve. NOTE THAT A SLIGHT AMOUNT OF HYDRAULIC FLUID WILL EJECT AT THIS POINT! MAKE SURE TO WEAR PROTECTIVE CLOTHING. RESQTEC Manual SPREADER X-series (DM064K08)
Please refer to the power unit’s user manual for additional information. (and open the valve). Rotate the control handle leftwards to open the arms. Keep the handle leftwards. Rotate the control handle rightwards to close the arms. Keep the handle rightwards. RESQTEC Manual SPREADER X-series (DM064K08)
The pin clicks when put in top position. If applicable: rotate the jaw 180°. Put the desired jaw back into place on the arms. Push the pin back into the arms. The pin clicks when put back into place. RESQTEC Manual SPREADER X-series (DM064K08)
You can now see the lock pin creates an opening for the chain to enter. Slide the chain into the chamber. Release the button of the pulling jaw. Make sure the chain is locked by the pin. RESQTEC Manual SPREADER X-series (DM064K08)
NFPA HPF 59.6 kN / 6.1 tons NFPA LPF 27.4 kN / 2.8 tons 66.3 – 120.9 kN/ Squeezing force at base of arm teeth 6.7 – 12.3 tons EN 13204 AS38.4-607-15.0 NFPA 1936 Compliant RESQTEC Manual SPREADER X-series (DM064K08)
Page 17
NFPA HPF 74.9 kN / 7.6 ton NFPA LPF 45.8 kN / 4.7 ton 176.7 - 289.0 kN / Squeezing force at base of arm teeth 18.0 - 29.5 ton EN 13204 AS53-687-21.2 NFPA 1936 Compliant RESQTEC Manual SPREADER X-series (DM064K08)
Page 18
NFPA HPF 74.2 kN / 7.6 ton NFPA LPF 52.8 kN / 5.4 ton 173.4 - 245.7 kN / Squeezing force at base of arm teeth 17.7 - 25.0 ton EN 13204 BS60.4-802-25.5 NFPA 1936 Compliant RESQTEC Manual SPREADER X-series (DM064K08)
13,399 lbs / 6.7 US ton NFPA LPF 6,160 lbs / 3.1 US ton 14,905 – 27,179 lbs / Squeezing force at base of arm teeth 7.5 - 13.6 US ton EN 13204 AS38.4-607-15.0 NFPA 1936 Compliant RESQTEC Manual SPREADER X-series (DM064K08)
Page 20
16,838 lbs / 8.4 US ton NFPA LPF 10,296 lbs / 5.1 US ton 39,724 – 64,970 lbs / Squeezing force at base of arm teeth 19.9 - 32.5 US ton EN 13204 AS53-687-21.2 NFPA 1936 Compliant RESQTEC Manual SPREADER X-series (DM064K08)
Page 21
16,681 lbs / 8.3 US ton NFPA LPF 11,870 lbs / 5.9 US ton 38,982 – 55,236 lbs / Squeezing force at base of arm teeth 19.5 - 27.6 US ton EN 13204 BS60.4-802-25.5 NFPA 1936 Compliant RESQTEC Manual SPREADER X-series (DM064K08)
Check the product and hoses for any • Check the unit for oil excessive leakage. If structural damage to the product damage. is discovered, contact your Resqtec • Check the arms for excessive wear. distributor/supplier. • Visually check for damage.
When in doubt ALWAYS replace the hose! Connect all components and test all • All tools should make at least two functions and accessories. complete cycles. RESQTEC Manual SPREADER X-series (DM064K08)
The product is connected to a power unit, but the arms will not open - Make sure the right valves on the power unit are opened. or close. - Make sure there is enough hydraulic oil and gasoline in the power unit. RESQTEC Manual SPREADER X-series (DM064K08)