1. Motion detection:Select this option to activate motion
sensing. Select the times during which the alarm settings
should be active.
2. Sensitivity: Enter the sensitivity for movement sensing
using a value between 0 and 9. The higher the value, the
higher the movement sensing sensitivity.
3. Use time schedule: You can restrict the period of time
during which alarms can be triggered. As soon as this
option is selected, the adjacent time schedule appears, in
which the active times can be selected.
4. Detection on digital input: In case of an alarm signal
through an alarm connection, this can be accepted by the
security camera, if this option has been activated.
5. Alarm level: States whether an alarm is signaled when no
voltage is applied to the alarm input (low setting), or when
voltage is applied (high setting).
6. Signal on digital output: As soon as an alarm signal is
received by the security camera, it is passed on via the
digital output, if this option is activated.
7. Alarm level (pn digital output): State whether the alarm
signal at the digital output is produced by an applied
voltage (high setting) or by the voltage ceasing to be
applied (low setting).