Error Code
2042
LdParamClear ERROR0
2043
LdParamClear ERROR1
2044
LdParamClear TIME OUT
2051
IopSet NG
2052
IopSet ERROR0
2053
IopSet ERROR1
2054
IopSet TIME OUT
2055
IopSet ERROR0
2056
IopSet ERROR1
2057
IopSet TIME OUT
2058
CD Iop LIMIT NG
2059
DVD Iop LIMIT NG
2060
BD Iop LIMIT NG
2081
LdParamVerify NG
2091
AtapiComCheck NG
2101
ID4 OFF NG
2111
SET BOR RATE NG
2200
Genaration NG
6001
Factory Info save Error
6002
Factory Info save Error
6100
Factory Info save Error
5. Saving The Pre-Operation OPU DATA
OPU DATA before performing the OPU DATA write is saved in a folder automatically.
5-1. When the OPU DATA write operation has been completed successfully, a folder named [FactoryInfo] is
created in the application folder (OpuDataWriter).
5-2. In the [FactoryInfo] folder, a folder is created monthly in which text file data are saved.
This text file is created with a file name of the OPU serial number and contains the pre-operation OPU DATA.
5-3. The text file is necessary for analyzing the defective BD Mechanism. Submit this text file with the defective
BD Mechanism as necessary to the appropriate managing Department.
Error
Cannot initialize LD Parameter.
Cannot initialize LD Parameter.
Cannot initialize LD Parameter (TimeOut).
Iop Set Error
Iop Set Error
Iop Set Error
lop Set Error (TimeOut)
Iop Set Error
Iop Set Error
lop Set Error (TimeOut)
CD Iop exceeds limit value.
DVD Iop exceeds limit value.
BD Iop exceeds limit value.
LD Parameter Verify Error
BE start Error.
Cannot set ID4 OFF.
Failed to change Serial Connection Rate.
Generation detect failure.
Failed to create FactoryInfo file.
Failed to create FactoryInfo file.
Failed to create FactoryInfo file.
Description
Pre-operation OPU DATA text file
Year(2010)Month(12)
1-8-6
HT3.5(2D)_HT_AIR