Sony CDP-C360Z Service Manual page 3

Hide thumbs Also See for CDP-C360Z:
Table of Contents

Advertisement

QQ
3 7 63 1515 0
MODEL IDENTIFICATION
— BACK PANEL —
CDP-CE415
US Model
CDP-CE415
Canadian Model
CDP-C360Z
US Model
NOTES ON HANDLING THE OPTICAL PICK-UP
TE
L 13942296513
BLOCK OR BASE UNIT
The laser diode in the optical pick-up block may suffer electrostatic
breakdown because of the potential difference generated by the
charged electrostatic load, etc. on clothing and the human body.
During repair, pay attention to electrostatic breakdown and also use
the procedure in the printed matter which is included in the repair
parts.
The flexible board is easily damaged and should be handled with
care.
NOTES ON LASER DIODE EMISSION CHECK
The laser beam on this model is concentrated so as to be focused on
the disc reflective surface by the objective lens in the optical pick-
up block. Therefore, when checking the laser diode emission,
observe from more than 30 cm away from the objective lens.
www
.
http://www.xiaoyu163.com
4-987-
: 784-0π
: 784-1π
: 784-2π
x
ao
u163
y
i
http://www.xiaoyu163.com
2 9
8
SAFETY CHECK-OUT
After correcting the original service problem, perform the
following safety checks before releasing the set to the customer:
Check the antenna terminals, metal trim, "metallized" knobs, screws,
and all other exposed metal parts for AC leakage. Check leakage as
described below.
LEAKAGE
The AC leakage from any exposed metal part to earth ground
and from all exposed metal parts to any exposed metal part having
a return to chassis, must not exceed 0.5 mA (500 microampers).
Leakage current can be measured by any one of three methods.
1.
A commercial leakage tester, such as the Simpson 229 or RCA
WT-540A. Follow the manufacturers' instructions to use these
instruments.
2.
A battery-operated AC milliammeter. The Data Precision 245
digital multimeter is suitable for this job.
3.
Measuring the voltage drop across a resistor by means of a
VOM or battery-operated AC voltmeter. The "limit" indication
is 0.75 V, so analog meters must have an accurate low-voltage
scale. The Simpson 250 and Sanwa SH-63Trd are examples of
a passive VOM that is suitable. Nearly all battery operated
digital multimeters that have a 2V AC range are suitable. (See
Fig. A)
Q Q
3
6 7
1 3
1 5
Fig. A. Using an AC voltmeter to check AC leakage.
co
.
— 3 —
9 4
2 8
(US model only)
0 5
8
2 9
9 4
2 8
To Exposed Metal
Parts on Set
AC
voltmeter
0.15 µ F
1.5k Ω
(0.75V)
Earth Ground
m