9 Troubleshooting

Pres-
Position of the
sure
adjusting screw
in MPa
(mbar)
5 further turns to
0.017
the left from the
(170)
mid-position
Install the front casing.
8.6

Handing the product over to the operator

When you have finished the installation, affix the en-
closed sticker (which requests that the user reads the
instructions) to the front of the product in the operator's
language.
Explain to the operator how the safety devices work and
where they are located.
Inform the operator how to handle the product.
In particular, draw attention to the safety information
which the operator must follow.
Inform the operator that they must have the product
maintained in accordance with the specified intervals.
Pass all of the instructions and documentation for the
product to the operator for safe-keeping.
Inform the operator about measures taken to ensure the
supply of combustion air and flue gas guiding, and in-
struct the operator that he must not make any changes.
Inform the operator that they must not store or use ex-
plosive or highly flammable substances (such as petrol,
paper or paint) in the installation room of the product.
Complete and sign off the Benchmark commissioning
check list.
Complete and sign off the guarantee documentation.
9
Troubleshooting
9.1

Comfort protection mode for the heat cell

Conditions: Neither
nor a fault code F.xx are shown in the display
Unusual operating noises are emitted from the heat cell in
the product.
Check whether S.40 is displayed in Live monitor.
If S.40 is displayed, the product is in a temporary test mode,
which it again exits automatically.
Conditions:
is displayed.
The Live monitor shows S.40 and D.118 is at 0. The heat
cell is in permanent comfort protection mode. This is not
caused by the all-gas sensor.
Decommission the product and check the entire air/flue
pipe.
Are there any blockages or leaks?
Eliminate the cause.
Are any components damaged?
Replace the defective components.
If the air/flue pipe is OK, restart the product.
Prepare the flue gas analyser for checking the recircula-
tion.
26
Notes/application
If noises are produced in
the radiators or radiator
valves
Installation and maintenance instructions ecoTEC exclusive 0020193966_01
The measuring probes must be rinsed and must not
be contaminated by a previous measurement.
Check for recirculation at the air test point. The following
measured values are indicators of recirculation.
Oxygen value in the intake air: < 20 vol. %
Intake air CO value: ≥ 100 ppm
Recirculation is present.
Eliminate the deficiencies in the air/flue pipe.
No recirculation is present.
Ensure that there is a heat requirement. In the
Live Monitor, check whether the product has the
status S.4 or S.14.
If the combustion values are not OK, carry out check
programmes P.4 and P.14.
Conditions:
and F.55 are displayed
The Live monitor shows S.40 and D.118 ≥ 1. The heat cell
is in permanent comfort protection mode.
Check and, if required, replace the all-gas sensor.
9.2

Checking service messages

To obtain further information, call up the Live monitor.
(→ Page 17)
Conditions: S.40 is displayed
The product is in Comfort protection mode. The product has
detected a temporary fault and continues to run with restric-
ted comfort. The product switches back to the normal operat-
ing mode.
To establish whether or not a component is defective,
read the fault memory. (→ Page 27)
Note
If no fault message is present, the product will
automatically switch back to normal operating
mode after a certain time.
Conditions: S.86 is displayed
The product remains in comfort safety mode and does not
switch back to normal operating mode.
Check the component that is mentioned and, if required,
replace it.
To establish whether or not a component is defective,
read the fault memory (→ Page 27).
appears if you have set a maintenance interval, for ex-
ample, and this has passed or a service message is issued.