Download Print this page
wattstopper LMRH-101 User Manual
wattstopper LMRH-101 User Manual

wattstopper LMRH-101 User Manual

Digital lighting management digital ir handheld remote

Advertisement

Quick Links

Handheld
Remote

SpecificationS

Power Supply . . . . . . 3 AAA batteries, 1 .5V alkaline or NiMH rechargeable
Environment:
Operating Temperature . . . . . . . . . . . . . . . . . . . . 32˚to 95°F (0˚to 35°C)
Storage Temperature . . . . . . . . . . . . . . . . . . . . 23 to 176°F (-5° to 80°C)
Relative Humidity . . . . . . . . . . . . . . . . . . . . . .5 to 95% (non condensing)
Other:
RoHS compliant, 5-year warranty
FCC part 15
This device complies with Part 15 of the FCC Rules . Operation is
subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation .
Unit DeScRiption
The WattStopper LMRH-101 Digital IR Handheld Remote uses an
infrared (IR) transmitter to send commands to a Digital Lighting
Management (DLM) network . It allows the user to turn lights ON/OFF
and dim without going to a wall box device .
The LMRH-101 operates on three AAA batteries . It communicates
wirelessly with other DLM devices by sending an IR signal to a DLM IR
enabled device within its range and line of sight .

Battery installation

The battery compartment holds three
standard 1 .5V AAA Alkaline batteries
(supplied) . Rechargeable NiMH batteries
can be used . Do not mix battery types . Do
not mix old batteries with new batteries .
LMRH-101
Digital Lighting Management
Digital iR Handheld Remote
Mounting
Holster

Advertisement

loading

Summary of Contents for wattstopper LMRH-101

  • Page 1: Specifications

    Management (DLM) network . It allows the user to turn lights ON/OFF and dim without going to a wall box device . The LMRH-101 operates on three AAA batteries . It communicates wirelessly with other DLM devices by sending an IR signal to a DLM IR enabled device within its range and line of sight .
  • Page 2 50% and turn ON when the ramp level rises above 50% . Battery Life To conserve battery life, the LMRH-101 shuts down 5 seconds after the last key press unless the LMRH-101 and the DLM local network is in configuration mode (Push n’ Learn, PnL) .
  • Page 3 When a load turns ON the blue LED is lit brightly on all switch buttons and sensors bound to the load . - To bind the load to the LMRH-101: While the load is ON press the paddle making sure that the blue LED turns ON brightly .
  • Page 4: Troubleshooting

    Load binding reset - To clear the unit so that it is not bound to any load: 1 . Do not point the LMRH-101 toward any DLM IR enabled device . 2 . Press and hold the configuration button in the battery compartment until the red LED goes solid ON (approximately 10 seconds) .