Saaa ALTEA 3-BUS User Manual

Bus control unit

Advertisement

USER'S GUIDE
USER'S GUIDE
Altea 3 BUS CONTROL UNIT
Update : 7/2/11
ALTEA 3 - BUS
and ALTEA 3 - BUS - DS
option alarm report
Z.A de la Croix saint-Mathieu
B.P.10022 - 28320 GALLARDON - FRANCE
Tel. (33) 02 37 33 69 69 - Fax. (33) 02 37 31 02 17 67
e-mail : info@saaa.fr
Centrale téléphonie
OZ NOT GB 0906

Advertisement

Table of Contents
loading

Summary of Contents for Saaa ALTEA 3-BUS

  • Page 1 ALTEA 3 - BUS - DS option alarm report USER’S GUIDE OZ NOT GB 0906 Z.A de la Croix saint-Mathieu B.P.10022 - 28320 GALLARDON - FRANCE Tel. (33) 02 37 33 69 69 - Fax. (33) 02 37 31 02 17 67 e-mail : info@saaa.fr...
  • Page 2 Vitrea USER GUIDE Thank you to have granted your confidence to us by buying a power station of alarm SAAA. This pro- duct was manufactured in the respect of the highest standards of quality. For a better use of your power station "Altea 3 BUS", we advise you to read the instructions attentively.
  • Page 3: Table Of Contents

    Special procedure: what to do if I have lost my red key ! ....... 22 Digital Signage option ................24 Computer connection via USB ................24 Kit includes Digital Signage Saaa ................ 24 Mise à jour du : 7/2/11 0Z NOT FR 0906...
  • Page 4: Getting Started

    Vitrea USER GUIDE 1.0/ Getting Started 1.1/ General cablage ON/OFF IR Receiver BLUE IR KEY and display 51511 53550 BUS lenght maxi = 15 m 56ANA1010 - 56ANA2020 Distributors Altea 3 BUS control unit 50630 50635 Power supply Sensors 52952 52909 ON/OFF 52916...
  • Page 5: The Ir Receiver / Lcd Display

    Vitrea USER GUIDE 2.0/ The IR receiver / LCD display The display consists of two 8 segments digit and a dot. It will provide information on your installation, how it is configured, and will assist in solving problems. This BUS C.U does not work with the 53500 I.R receiver 2.1/ Information provided by the 8 segments digit 53550: On some occasions (described later on in this user's guide), the display will be toggling between a number (1 to 8) and a 3 horizontal bars pattern.
  • Page 6: Displayed At The Start

    Vitrea USER GUIDE 2.4/ Displayed at the start In the first operation of the control unitdisplay alternately shows the following information: Numbre de Nombre de Number of Number of empty empty PRESENT Stik empty sensors distributors sensors sensors First failure Second failure etc ...
  • Page 7: First Startup

    Vitrea USER GUIDE 3.0/ First startup. 1 - Opun the battery compartment 2 - Insert 3 standard AA batteries into the control unit 3 - Close the battery compartment. 4 - Connect the IR receiver / display to the control unit At this stage, you may want to already connect up to 8 sensors to the control unit or you may want to power it up with no sensors and add them one by one later while the control unit is ON.
  • Page 8: Plug & Play Procedure

    Vitrea USER GUIDE 4.0/ Plug & Play procedure 4.1/ Control Unit Initializing Start the Control Unit (without connecting sensors or with sensors connected but not stuck) without connec- ting distributors. The left display show nothing and the middle dash blink on the right display (internal dis- tributor).
  • Page 9: Blanking

    Vitrea USER GUIDE If you wish program several distributors in this mode, press briefly as much as necessary to reach the number you chosen or do nothing if the chosen address is the following and, within 5 seconds, connect the distri- butor which will get this new address and stabilize the display.
  • Page 10 Vitrea USER GUIDE If only one telephone is missing or one sensor is not working The LCD display toggles between Distributor number Type of non-working failed sensor > Top digit is lit: > Top digit is lit: Nano sensor is not working Nano sensor is not working >...
  • Page 11: Adding A Product To An Existing Configuration

    Vitrea USER GUIDE 7.0/ Adding a product to an existing configuration Adding products is automatic. Just stick the appropriate sensors on the product you want to add and connect it to the control unit. ADD A PRODUCT Peel the plastic Peel the plastic Stick Stick...
  • Page 12: Alarm Management

    Vitrea USER GUIDE 8.0/ Alarm management When an alarm is triggered, a loud audio sound will be heard and the display will show a "A". ALARM ! Theft attempt Example: telephone n°8 Loud audio signal 2 3 3 4 4 5 5 6 6 7 7 It is of course highly recommended to immediately look around and find out if anyo- ne is trying to tamper with the system.
  • Page 13: Repair Mode

    Vitrea USER GUIDE 9.0/ Repair mode A short press on a blue or green key while there is no alarm will enter the repair mode. If the Altea 3 finds problems that require your attention it will indicate them through the LCD display: REPAIR MODE The LCD display toggles between the number of the position where a problem was...
  • Page 14: Alarm Default Bus

    BUS distributor Défault ALTEA 3 BUS Controle Unit SAAA Sensors The display shows a "b" if NO distributor is recognized by the control unit. The display shows a "b" if NO distributor is recognized by the control unit. BUS distributor BUS distributor Défault...
  • Page 15: Stop The Altea 3 (Not Recommended)

    Vitrea USER GUIDE 10.0/ Stop the Altea 3 (not recommended) Caution: stopping the control unit will leave all products un-protected. 5’' 3 audio beeps CONTROL UNIT “OFF” Pressing more Pressing more than 5 secs than 5 secs Red remote control Red remote control 11.0/ Resetting the configuration A long (more than 10 secs) press on the blue key will stop the control unit (=nothing protected), and com-...
  • Page 16 Vitrea USER GUIDE unit being still switched ON (= all products are duly protected). REMOVING PRODUCTS The LCD display will You have 5 seconds show a specific pattern to take product off 5’' Briefly press Briefly press the remote the remote control button control button yellow remote control...
  • Page 17: Adding A Distributor

    Vitrea USER GUIDE 13.0/ Adding a distributor Distributors will be taken automatically after the connection on the bus when the controle unit is operating. There will be a 30 second delay before taking effect. There will be flashing digit left (number distributor) during this phase.
  • Page 18: Key Usage

    Vitrea USER GUIDE 14.0/ Key usage 14.1/ Getting started If your Altea 3 is brand new or if it has been totally reset (configuration and key reset), the display will show clock wise revolving digits. That means that NO key is currently associated to (= known by) the control unit. In that state, only a blue or red key can be recognized and associated to the Altea 3, which means you have two options: Option 1: associating a blue key (with red key) >...
  • Page 19: Associating A Red Key To A Altea 3 (When The Blue Key Is Allready Allocated)

    Vitrea USER GUIDE 14.2/ Associating a RED key to a Altea 3 (when the blue key is allready allocated) 1 - switch the Altea 3 OFF (by pressing more than 5 secs on a valid blue key) 2 - Short press on the red key: a C will be briefly displayed and the red key will be associated to the Altea 3.
  • Page 20: Associating Blue, Green Or Yellow Keys To A Altea 3

    Vitrea USER GUIDE 14.3/ Associating blue, green or yellow keys to a Altea 3 Have a valid red key + all the new keys you wish to associate to the control unit ready and next to you. 1 - Whether the Altea 3 is ON or OFF, short press on a valid red key: the display shows 2 - You have then 5 secs to associate a new blue, green or yellow key to the Altea 3, by just pressing on the key.
  • Page 21: Deleting A Key From The Altea 3

    Vitrea USER GUIDE 14.4/ Deleting a key from the Altea 3 There is NO WAY to remove the keys associated to a Altea 3 ONE by ONE. The only procedure is actually to delete ALL keys at once, then to re-enter the keys you wish. 1 - Long press on the red key (>...
  • Page 22: Special Procedure: What To Do If I Have Lost My Red Key

    Vitrea USER GUIDE 4 - Replace the batteries 5 - Put the lid back into place and screw it 6 - Reconnect the power supply, the Altea 3 automatically starts. Note: if for any reason, you reconnect the power supply to the Altea 3 while the case is opened, you must know that you have one minute to put the lid back into place, otherwise the alarm will be triggered and the display will show "o"...
  • Page 23 Vitrea USER GUIDE 5 - take the batteries off WAIT ONE MINUTE 5’' 3 audio beeps CONTROL UNIT Pressing more Pressing more “OFF” than 5 secs than 5 secs Red remote control Red remote control Pressing more Pressing more than 5 secs than 5 secs 1 minute Short Press...
  • Page 24: Digital Signage Option

    17.1/ Computer connection via USB REAR VIEW Altea 3 BUS Control Unit Optional Output USB 17.2/ Kit includes Digital Signage Saaa ALTEA 3 BUS - DS Soft Cd-Rom Digital Signage Saaa control unit Mini-USB Update : 7/2/11 0Z NOT FR 0906...