CAUTION!!
terminal. Otherwise, overheating may occur.
CAUTION!!
connected tightly.
CAUTION!!
positive (+) must be connected to positive (+) and negative (-) must be connected to negative (-).

AC Input/Output Connection

CAUTION!! Before connecting to AC input power source, please install a separate AC breaker between
inverter and AC input power source. This will ensure the inverter can be securely disconnected during
maintenance and fully protected from over current of AC input. The recommended spec of AC breaker is 50A.
CAUTION!! There are two terminal blocks with "IN" and "OUT" markings. Please do NOT mis-connect input
and output connectors.
WARNING! All wiring must be performed by qualified person.
WARNING! It's very important for system safety and efficient operation to use appropriate cable for AC input
connection. To reduce risk of injury, please use the proper cable size as recommended below.
Suggested cable requirement for AC wires
Model
G1 Solar MPPT
Please follow the steps below to implement AC input/output connection:
1. Before making AC input/output connection, be sure to disconnect DC protector or breaker on battery
terminal first.
2. Remove insulation sleeve 10mm for six conductors.
3. Insert AC input wires according to polarities indicated on terminal block and tighten the terminal screws. Be
sure to connect PE protective conductor (
→Ground (yellow-green)
L→LINE (brown or black)
N→Neutral (blue)
WARNING:
Be sure that AC power source is disconnected before attempting to fix the wire of the unit.
10
INFOSEC UPS SYSTEM - 15, rue du Moulin - 44880 Sautron - FRANCE - www.infosec-ups.com
Hot Line – Tel + 33 (0)2 40 76 15 82 - Fax + 33 (0)240 94 29 51 - hotline@infosec.fr – 08 17 AA 59 201 05
Do not place anything between the flat part of the inverter terminal and the ring
Do not apply anti-oxidant substance on the terminals before terminals are
Before making the final DC connection or closing DC breaker/disconnector, be sure
Gauge / Section
8~10 AWG / 6-10 mm2
) first.
Torque Value
1.4~ 1.6Nm