Control Panel Instructions; Error Codes; Indicator Light Functions - ALDI EDR050BAUW User Manual

50 pint dehumidifier
Table of Contents

Advertisement

Available languages

Available languages

Operating

Control panel instructions

Filter
Continuous
Operation
Timer
When you push the button to change operation modes, the unit
will make a beeping sound to indicate that it is changing modes.
Continuous button: Press to activate the continuous
1.
dehumidifying operation.
Filter button: The check filter light will illuminate after 250
2.
hours of operation. After cleaning the filter, press the filter
button and the light will go off.
Fan button: Controls the fan speed. Press to select either
3.
normal or high fan speed.
Power button: Press to turn the dehumidifier on or off.
4.
( + / - ) buttons: The humidity level can be set within a
5.
range of 35% RH (Relative Humidity) to 85% RH in 5%
increments using these buttons. For drier air, press the (-)
button and set to a lower percentage value (%). For more
damp air, press the (+) button and set a higher percentage
value (%).
Timer button: Press to initiate the auto-start and au-
6.
to-stop feature. Set a start or stop time from 0.0 to 24
hours using the (+) and (-) keys.
Display: Shows the actual (± 5% accuracy) room humidity
7.
level in a range of 30% RH to 90% RH. Otherwise, dis-
plays selection when programming humidity or timer.
Note: The fan does not shut off the moment you remove the
bucket, the fan will shut off after 2-3 minutes.
10
Fan
Power

Error codes

AS - Humidity sensor error
ES - Temperature sensor error
P2 - Bucket is full or the bucket is not in correct position
EC - Ensure that the room ambient temperature match-
es the recommended operating temperature for the unit,
5°C (41°F) - 35°C (95°F).

Indicator light functions

Note: Depending on the humidity conditions of the surrounding
environment, the dehumidifier may not start automatically when
the "on/off" button is pressed (see dehumidifying mode instruc-
tions for details).
Memory setting: Each time the unit is disconnected / re-con-
nected and/or in the event of a power failure, the electronic
circuit board automatically defaults to the last program setting
that was used. After the unit has stopped, it may take several
minutes before operating conditions resume.
Auto-restart: If the unit shuts off unexpectedly due to a power
outage, it will restart with the previous function settings auto-
matically when the power resumes.
Bucket full indicator light: When the bucket is full and/or
incorrectly positioned inside the cabinet, the bucket full light will
turn on and remain on until the bucket is emptied and/or cor-
rectly re-positioned. This condition will result in the immediate
shut down of the dehumidifying system (both compressor and
fan motor operations are terminated). This is a safety feature.
When the bucket is emptied and/or correctly re-positioned, the
dehumidifier will resume operation automatically. Note: It may
take several minutes before operating conditions resume.
Auto-defrost: When frost builds on the evaporator coils, the
compressor will cycle off and the fan will continue to run until
the frost disappears.