Adjustment - Kenwood 1060CD Service Manual

Hide thumbs Also See for 1060CD:
Table of Contents

Advertisement

1060CD/1070CD/DP-R6090/R7090/D-R350
QQ
3 7 63 1515 0
No.
ITEM
Step 1~4 are in TEST MODE
1
LASER POWER
TRACKING ERROR
2
BALANCE
FOCUS ERROR
3
BALANCE
4
TRACKING GAIN
Note:
TE
L 13942296513
Type 4 disc : SONY YEDS-18 Test Disc or equivalent.
LPF: Around 47 kΩ+ 390 pF or so.
(a) Laser power
Pickup
www
.
4

ADJUSTMENT

INPUT
OUTPUT
SETTINGS
SETTINGS
Apply the sensor section
of optical power meter
on the pickup lens.
Connect an oscilloscope
Test disc
as follows.
Type 4
CH1 : RF (CN2 pin 1)
CH2 : TE (CN2 pin 6)
Connect an oscilloscope
Test disc
as follows.
Type 4
CH1 : RF (CN2 pin 1)
CH2 : FE (CN2 pin 2)
Test disc
Type 4
Connect a LPF to CN2
Apply signal of
pin 5-6 to which you
1.2 kHz,
connect an oscilloscope
50mVrms to
or AC voltmeters.
CN2 pin 5-6.
0.08~0.15 mW
Optical power meter
x
ao
y
i
8
PLAYER
SETTINGS
While pressing the
RANDOM key, turn
the AC ON. (Test
mode) Press the
PLAY/PAUSE key,
then confirm that the
display is "03".
Press the
PLAY/PAUSE key,
then confirm that the
display is "03".
Press the
PLAY/PAUSE key,
then confirm that the
display is "05".
Press the
PLAY/PAUSE key,
then confirm that the
display is "05".
Q Q
3
6 7
1 3
(e) Tracking gain
_
1.2 kHz
50 mVrms
+
u163
.
2 9
9 4
2 8
ALIGNMENT
ALIGN
POINTS
FOR
On the power from
0.08 to 0.15 mW,
when the diffraction
grating is correctly
aligned with the RF
level of 1.0 Vp-p or
more.
Symmetry between
TE BALANCE
upper and lower pat-
VR2
terns
FE BALANCE
Optimum eye pattern
VR1
TRACKING
Two VTVMs should
GAIN
read the same value.
VR3
1 5
0 5
8
2 9
9 4
CN2
1
2
GND
3
4
+
L.P.F.
VTVM
5
6
+
L.P.F.
VTVM
7
m
co
9 9
FIG.
(a)
(e)
2 8
9 9

Advertisement

Table of Contents
loading

This manual is also suitable for:

R7090d-r3501070cdDp-r6090