Loreme THL36 Configuration Handbook

Temperature protection relay temperature regulator

Advertisement

Quick Links

TEMPERATURE PROTECTION RELAY
TEMPERATURE REGULATOR
CONFIGURATION HANDBOOK
THL36
LOREME 12, rue des Potiers d'Etain Actipole BORNY - B.P. 35014 - 57071 METZ CEDEX 3
Phone 03.87.76.32.51 - Telefax 03.87.76.32.52
Contact : Commercial@Loreme.fr - Technique@Loreme.fr
Download manual at : www.loreme.fr
REV 0.2 - 19/02/16
E 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the THL36 and is the answer not in the manual?

Questions and answers

Summary of Contents for Loreme THL36

  • Page 1 TEMPERATURE PROTECTION RELAY TEMPERATURE REGULATOR CONFIGURATION HANDBOOK THL36 LOREME 12, rue des Potiers d'Etain Actipole BORNY - B.P. 35014 - 57071 METZ CEDEX 3 Phone 03.87.76.32.51 - Telefax 03.87.76.32.52 Contact : Commercial@Loreme.fr - Technique@Loreme.fr Download manual at : www.loreme.fr REV 0.2 - 19/02/16...
  • Page 2 2.1) General remarks .......................... p6 2.2) Power Supply ..........................p6 2.3) Inputs / Outputs ........................... p6 WIRING / OUTLINE DIMENSIONS .......................... LOREME 12, rue des Potiers d'Etain - 57071 Metz  03.87.76.32.51 - Fax 03.87.76.32.52 - Email: Commercial@Loreme.fr - Technique@Loreme.fr...
  • Page 3 Device Presentation THL36 is a digital thermostat usable for simple temperature regulation (heating or cooling). It is fully programmable from the front side. The device can be used with 2 or 3 wires PT100 sensors or with J, K, T thermocouple, temperature com- pensated.
  • Page 4 - low threshold detection (heating): .alarm is activated when temperature goes below threshold, .alarm is removed when temperature goes above threshold plus hysteresis. LOREME 12, rue des Potiers d'Etain - 57071 Metz  03.87.76.32.51 - Fax 03.87.76.32.52 - Email: Commercial@Loreme.fr - Technique@Loreme.fr...
  • Page 5  TABLE OF CONTENTS The configuration possibilities are: ‘AHi’ - High detection with the display ‘ALo’ - Low detection with the display The actual configuration is displayed on topic access.   Pressing button validates the displayed choice and ends the configuration. Press button to display next choice.
  • Page 6 - It is advisable to separate the input / output lines from the power supply lines in order to avoid the coupling phenomena. - It is also advisable to limit the lengths of data cables as much as possible. LOREME 12, rue des Potiers d'Etain - 57071 Metz  03.87.76.32.51 - Fax 03.87.76.32.52 - Email: Commercial@Loreme.fr - Technique@Loreme.fr...
  • Page 7  TABLE OF CONTENTS Wirings / Outline dimensions  Power supply terminals 7 & 8. Relay terminals Work (10), Rest (11), Common (12). PT100 input terminals 4(+), 5(-), 6(line). Thermocouple input terminals 4(+), 5(-).