  • Page 2 MobileCollect Selection Tool Copyright © 2011-2017 MicroRidge Systems, Inc. All rights reserved. No parts of this work may be reproduced in any form or by any means - graphic, electronic, or mechanical, including photocopying, recording, taping, or information storage and retrieval systems - without the written permission of the publisher.
  • Page 3: Table Of Contents

    Selection Tool Tabs ........................... Cables & Mobile Modules ........................RS-232 Remotes ........................Bases ........................Summary ........................Printed Summary ........................... Chapter 6 Purchase Orders ........................... Chapter 7 Warranty Information ........................... Chapter 8 Contact MicroRidge ........................... Copyright © 2011-2017 MicroRidge Systems, Inc.
  • Page 4: Chapter 1 Introduction

    A Base is required for each PC that will be receiving wireless measurements. § Print a summary report showing all of the items selected. This report shows individual and total prices. § Save the configuration to a file for later retrieval. Copyright © 2011-2017 MicroRidge Systems, Inc.
  • Page 5: Chapter 2 Mobile Modules

    The Mini Mobile Module and the Digital Mobile Module are very similar. The primary differences between these 2 Mobile Modules are listed below. § The Mini Mobile Module is less than half the size (measured on a volume basis) of a Digital Mobile Module. Copyright © 2011-2017 MicroRidge Systems, Inc.
  • Page 6: Rs-232 Mobile Module

    Command Mobile Module will function the same as a Digital Mobile Module. Contact MicroRidge to learn more about the Command Mobile Module and to determine if it is appropriate for your application. Copyright © 2011-2017 MicroRidge Systems, Inc.
  • Page 7: Chapter 3 Gage Cables

    The standard cable lengths are as follows: Length Typical Usage 3.5" Standard for calipers 6.5" Most micrometers & indicators 9" Available by special request 12" Available by special request 18" Available by special request 24" Available by special request Copyright © 2011-2017 MicroRidge Systems, Inc.
  • Page 8: Mobile Module Connectors

    These cables use a 2x3 connector. Digital Mobile Module These cables use a 2x7 connector. Command Mobile Module This Mobile Module uses the same cable as the Digital Mobile Module. RS-232 Mobile Module These cables use a 2x6 connector. Copyright © 2011-2017 MicroRidge Systems, Inc.
  • Page 9: Chapter 4 Gage & Price Updates

    To update the Selection Tool on your PC, you must download the installation file and then run this file to install the updated MobileCollect Selection Tool. The MobileCollect Selection tool has been tested on Windows XP and Windows 7. Copyright © 2011-2017 MicroRidge Systems, Inc.
  • Page 10: Chapter 5 Selection Tool Operation

    (Cables & Mobile Modules), select the gages you will be using and then proceed to the next tab. The last tab (Summary) will show the results of all of the selected items. Copyright © 2011-2017 MicroRidge Systems, Inc.
  • Page 11: Cables & Mobile Modules

    The selection grid will not simultaneously display the cable part numbers for both the Mini and digital Mobile Modules. Copyright © 2011-2017 MicroRidge Systems, Inc.
  • Page 12 Select button. § In the lower grid, modify the quantity fields as necessary. The Selection Tool will automatically update the number and type of Mobile Modules required. Copyright © 2011-2017 MicroRidge Systems, Inc.
  • Page 13: Rs-232 Remotes

    USB interface cable is only required is you need to configure the RS-232 Remote with a computer that does not have a serial port. The USB interface cable is not used to connect your serial device to the RS-232 Remote. Copyright © 2011-2017 MicroRidge Systems, Inc.
  • Page 14: Bases

    BASE-SP-PKG product. The USB interface cable is only required if you need to configure and/or use an RS-232 Base with a computer that does not have a serial port. Contact MicroRidge if you have question about the Base selection process. Copyright © 2011-2017 MicroRidge Systems, Inc.
  • Page 15: Summary

    The Reference field in the upper left corner of the window allows you to enter a description (i.e., customer name, etc) for the currently selected items. You can also save a copy of the selection summary to a file. Copyright © 2011-2017 MicroRidge Systems, Inc.
  • Page 16: Printed Summary

    If you want to print this summary to a PDF file, you must have a PDF Writer installed on your computer. Copyright © 2011-2017 MicroRidge Systems, Inc.
  • Page 17: Chapter 6 Purchase Orders

    MicroRidge Systems. Purchase orders must contain complete information such as billing address, shipping address, payment method, etc. However, you can submit a standard company purchase order and use the printed summary as an attachment to this purchase order.
  • Page 18: Chapter 7 Warranty Information

    MicroRidge in writing of such defect within thirty (30) days of discovery and returns such products in accordance with the MicroRidge instructions. No products may be returned without MicroRidge prior written authorization.
  • Page 19: Chapter 8 Contact Microridge

    MicroRidge Systems, Inc. 56888 Enterprise Drive Sunriver, OR 97707 Note: There is no mail delivery to this address. This address should only be used for package delivery services such as UPS, FedEx, etc. Web: www.microridge.com Copyright © 2011-2017 MicroRidge Systems, Inc.