Technical Data - Whirlpool ACCESS AWM 8900-ROK Service Manual

Table of Contents

Advertisement

16.04.2007 / Page 2
Doc. No: 4812 722 27545

Technical data

Dimensions
Height
Width
Depth
Weight
Net
Main connection
Voltage
Frequency
Power consumption
Fuse rating
Drum
Volume
Wash spin
Ramp spin
Speed spinning max.
Capacity of dry laundry
Capacity of dry laundry
Cotton/coloured laundry
Synthetics
Daily load 40˚C
Quick Wash 30˚C
Delicate
Handwash
Wool
Big Items
Gentle Spin
Spin
Rinse & Spin
Pressostat for washing-machine
Level1
Switching point
Reset
Overflow
Switching point
Water column drum
(measured inside of the drum, rear position)
Level1
Switching point
Overflow
Switching point
AWM 8900-ROK
8570 082 74000
96.5
cm
68.6
cm
78.5
cm
113
kg
230
V
60
Hz
2.2
kW
10
A
92
l
35/40
rpm
100
rpm
1200
rpm
9.0
kg
4.0
kg
4.0
kg
4.0
kg
2.5
kg
2.0
kg
2.0
kg
2.5
kg
4.0
kg
9.0
kg
9.0
kg
55 ± 5
mmWc
35 ± 5
mmWc
280 ± 20
mmWc
39 - 50
mm
235 - 300
mm
Whirlpool Europe
Customer Service
Nominal current
Contacts:
11 - 12
11 - 14
11 - 16
Contactsystem:
11 - 12 - 14
11 - 16
Damping system
Door lock
Nominal current:
contacts
4 - 5
6 - 7
8 - 9
Coil 1 - 2 and 2 - 3:
Nominal voltage
Frequency
Resistance 1 - 2 (lock)
Resistance 2 - 3 (unlock)
Locking time
Unlocking time
(max.6 cyles)
Heating element
Kind of heating
Nominal voltage
Nominal power
Heat conductor
resistance R25
Resistance NTC:
0 ˚C
30 ˚C
40 ˚C
50 ˚C
60 ˚C
70 ˚C
95 ˚C
S E R V I C E
~3 mA
24 V DC
~3 mA
24 V DC
~3 mA
24 V DC
jump contacts
slow action contacts
no
16 A
230 V
16 A
230 V
0.1 A
230 V
230
V
45 - 65
Hz
Ω ± 10%
133
Ω ± 10%
140
40 ± 10
ms
1
s
Tubular heating element
with NTC- Sensor
230
V
2050
W
22 - 28
35.9
kΩ
9.8
kΩ
6.6
kΩ
4.6
kΩ
3.2
kΩ
2.3
kΩ
1.1
kΩ

Hide quick links:

Advertisement

Table of Contents
loading