Hide thumbs Also See for ViMove2:
Table of Contents

Advertisement

Quick Links

USER MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ViMove2 and is the answer not in the manual?

Questions and answers

Summary of Contents for dorsaVi ViMove2

  • Page 1 USER MANUAL...
  • Page 2: Table Of Contents

    2.1.2 Sensor light status colour guide ......6 7.1.5 View Run Live Assessment data ......22 2.1.3 Charging your ViMove2 sensors ......6 7.1.6 Share a report ............23 2.1.4 Turning your ViMove2 sensors on ......6 2.2 Sensor Adhesives ............7 8. ViMove2 Knee 2.3 Sensor Overwraps ............7 8.1 Knee Live Assessment ..........24...
  • Page 3: Regulatory Information

    1. Regulatory Information 1.1 Symbols and labeling information The following table lists the labels attached to various components of ViMove2. Symbol Explanation Symbol Explanation Follow instructions for use AU / NZ safety certification Authorised European Class II equipment Representative Type B Applied Part...
  • Page 4: Indications For Use

    The potential adverse reactions that may be experienced with use ViMove2 at all if the allergy is of a serious nature. the use of the device include: •...
  • Page 5: Conformance To Standards

    Electromagnetic compatibility dorsaVi software be protected with a password. Furthermore, - Requirements and tests a strong password should be chosen for the user’s ViMove2 Medical devices - Symbols to be used account. The following are characteristics of a strong password: with medical device labels, labeling, •...
  • Page 6: System Description

    ViMove2 then measures the movement, streams the data live via Bluetooth Low Energy (BTLE) to a tablet or smartphone, and generates a personalised assessment including comparisons to normative values.
  • Page 7: Sensor Adhesives

    3.3 Software installation ViMove2 can be download from the Apple App Store on your compatible tablet device. To download the software, open the App Store, search for “ViMove2” and follow the prompts to download and install the software. Once the installation has finished, a “ViMove2” app icon will appear on your home screen.
  • Page 8: Getting Started

    4.1 Logging into your clinic To login to ViMove2 for the first time, you will receive an email from dorsaVi containing a temporary password to gain access to your clinic. Follow the prompts in this email to login to your clinic and set a new password for your account. For subsequent logins, open the ViMove2 app, enter your login details (email address and password) and press “Login”.
  • Page 9: Patient Exercise Program Screen

    All patient information and assessment data recorded by ViMove2 is securely stored in dorsaVi’s central servers. To store this information or share it with other users in the clinic, data must be “synced” between the ViMove2 app and the servers. To check if your device is synced refer to the “sync status”...
  • Page 10: Low Back Live Assessment

    Push the button on the side of the Peel the Sensor Adhesives off the the patient you would like to test and ViMove2 sensors to turn them on. adhesive roll and apply to the back of select “New Test”. Following the on- From the sensor selection screen, tap the ViMove2 sensors.
  • Page 11: Standing Lumbar Tests Screen

    11. Select the movements you want your patient to perform. For the first four movements of the Low Back Live Assessment you can use ViMove2’s “Auto Capture” mode (denoted by the “A” symbol next to the applicable tests). This mode allows patients to perform the first four movements without having to manually start and stop each movement.
  • Page 12: Standing Pelvic Tilt Test Screen

    Record pain scores for movements that caused the patient pain. anterior and posterior tilt movement in real-time as they perform The pain score must be recorded while ViMove2 is capturing pelvic tilt tests. movement data for the score to be tied to the selected test.
  • Page 13: Sitting Pelvic Tilt Test Screen

    Record pain scores for movements that caused the patient pain. anterior and posterior tilt movement in real-time as they perform The pain score must be recorded while ViMove2 is capturing the sitting pelvic tilt test. movement data for the score to be tied to the selected test.
  • Page 14: Live Assessment Test Protocol

    Ask the patient to sit in a comfortable position with their arms crossed over their chest. Ask the patient to rotate their trunk as far as possible in the direction indicated on ViMove2 while keeping their pelvis steady, hold position for 2 seconds and then return to the start position.
  • Page 15: Viewing Assessment Data

    The detailed view screen provides an in-depth look at the individual movements performed by the patient so clinicians can pinpoint areas of concern and re-watch selected movements using the ViMove2 avatar. View a general overview of the assessment report and suggested This area displays the movement data obtained throughout the exercises based on the patient’s movements throughout the test.
  • Page 16: Compare Assessment Data

    After selecting a report type you will be able to view the patient’s Live Assessment data and notes in ViMove2. Select the mail button located in the bottom right hand corner to email the report as a PDF document and select the arrow icon to expand the report on the screen.
  • Page 17: Low Back Monitoring

    Push the button on the side of the Peel the Sensor Adhesives off the the patient you would like to test and ViMove2 sensors to turn them on. adhesive roll and apply to the back of select “New Test”. Following the on- From the sensor selection screen, tap the ViMove2 sensors.
  • Page 18: Offloading Monitoring Session Data

    At the conclusion of the Monitoring session, the patient will need to return to the clinic. Upon their return, remove the ViMove2 sensors from the patient, navigate to the patient’s profile on ViMove2 and select “Download Monitoring data”. ViMove2 will then locate the two sensors used during the Monitoring session and offload the data to your clinic.
  • Page 19: Viewing Monitoring Session Data

    6.2.5 Share a Low Back Monitoring session report To share a Live Assessment report select the “Share” icon located in the top right hand corner of the ViMove2 app while viewing a report. After selecting this option you will be able to view the patient’s Monitoring data and notes in ViMove2. Using the mail button located in the bottom right hand corner to mail the report as a PDF document, and select the arrow icon to expand the report.
  • Page 20: Run Live Assessment

    Using the ViMove2 Tibia template Place the ViMove2 sensor on the tibia Repeat steps 4 and 5 for the opposite place the zero line of the ruler on in portrait orientation so it sits in the leg.
  • Page 21: Live Assessment Screen

    ViMove2. Failure to do so will result in incorrect, incomplete and in some cases null data being recorded. Once a test has been completed, ViMove2 will populate the test with the running movement data allowing you to see the patient’s running metrics immediately.
  • Page 22: Run Metrics Overview

    7.1.4 Run metrics overview ViMove2 Run captures a wide array of metrics during a patient’s run. Below is an overview of each metric captured by ViMove2 Run. ASI - Absolute Symmetry Index ASI measures the percentage of asymmetry between average GRF values of the left and right legs. ASI is typically calculated as follows: ASI = 100 * ((LEFT GRF VALUE –...
  • Page 23: Share A Report

    7.1.6 Share a Run Live Assessment report To share a Live Assessment report select the “Share” icon located in the top right hand corner of the ViMove2 app while viewing a report. After selecting this option you will be able to view the patient’s Live Assessment data and notes in ViMove2. Use the mail button located in the bottom right hand corner to mail the report as a PDF document, and select the arrow icon to expand the report.
  • Page 24: Knee Live Assessment

    Using the ViMove2 Tibia template Place the ViMove2 sensor on the tibia Repeat steps 4 and 5 for the opposite place the zero line of the ruler on in portrait orientation so it sits in the leg.
  • Page 25: Live Assessment Screen

    Selecting a repetition performed during the assessment will display this button. Pressing this button will delete the repetition Reference values for the most recent repetition recorded. from the assessment. Patient’s knee test data for the most recent repetition recorded. ViMove2 INT User Manual | A474.B...
  • Page 26: Live Assessment Test Protocol

    8.1.3 Knee Live Assessment test protocol In ViMove2’s Knee Live Assessment the following movements can be tested. For all tests, use the “Start Capture” and “Stop Capture” buttons located at the bottom right hand corner of the screen to record the following movements. To move on to the next test select the “Next”...
  • Page 27: View Live Assessment Data

    8.1.5 Share a Knee Live Assessment report To share a Live Assessment report select the “Share” icon located in the top right hand corner of the ViMove2 app while viewing a report. After selecting this option you will be able to view the patient’s Live Assessment data and notes in ViMove2. Use the mail button located in the bottom right hand corner to mail the report as a PDF document, and select the arrow icon to expand the report.
  • Page 28: Myvimove

    Version: 10.2.0 (or newer). 9.3 Inviting your patients to myViMove When a patient profile is created in ViMove2, you will be able to send an email to the patient with details about how to download and log into the myViMove app. These details can be re-sent at any time by going into the patient’s profile.
  • Page 29: Device Specifications

    >16 km/h Running Data Accuracy GRF Accuracy 130N 140N 150N Movement Type Slow Movement Dynamic Movement Knee Data Accuracy Sagittal 1.5° 2.0° Frontal 3.0° 5.0° *For subjects with body masses between 75kg and 100kg. ViMove2 INT User Manual | A474.B...
  • Page 30: Normative Data

    NOTE: The normative values displayed in the ViMove2 Live Assessment reports are based on the mean and 95% confidence intervals calculated for each age group, using combined male and female values.
  • Page 31: Vimove2 Store

    Visit http://dorsavi.com/vimovestore to order through our online store. 14. Troubleshooting Unsure about a part of our software or need extra help to use ViMove2? Visit http://dorsavi.com/vimove2support to view troubleshooting guides and FAQ’s related to ViMove2 and myViMove. 15. dorsaVi Contact Details...
  • Page 32 For more information about ViMove2 or dorsaVi visit or call: info@dorsavi.com | www.dorsavi.com AU: +61 3 9652 2198 UK: +44 20 3457 0777 US: 800-961-0772 Melbourne | London | New York dorsaVi and ViMove2 are trademarks of dorsaVi Limited. © dorsaVi Limited 2017 / A474.B...

Table of Contents