Advanced Setup
Before entering Advanced Setup, use the Mode button to place the unit in OFF.
These steps are normally set up by the installer. Setting these values
incorrectly may result in improper operation. Setup steps 1 & 2 are found in
the clock set section.
Press the Mode button.
MODE
While holding the Mode,
press the Program button
PROGRAM
to enter Setup screens.
Press
FAN
Reset the Service Filter
counter to 0, to remove
the icon from the display.
Adjust the number of
hours the blower will
run before the Service
Filter icon appears on
the display. 0 = off.
(0 - 1950)
Select Heat Pump
operation (ON) or,
Gas/Electric
operation (OFF).
B
Select reversing
valve type, O or B.
(Step 6 appears if
step 5 is ON.)
O
NOTE: Each step # is located at
the top right corner of the
display for easy reference.
3
0
Setup
ServiceFilter
4
0
Setup
ServiceFilter
5
Setup
OFF
6
0
Setup
Continued
Page 13
Press
MODE
Press
MODE
Press
MODE
Press
MODE